Analysis of back-flashover lightning- withstanding level of 500-kv-double-circuit transmission lines

被引:0
|
作者
Wu, Shihong [1 ]
Wen, Xishan [1 ]
Li, Rui [1 ]
Xu, Yang [1 ]
机构
[1] College of Electrical Engineering, Wuhan University, Wuhan,430072, China
来源
关键词
Timing circuits;
D O I
10.1007/978-3-319-13707-0_43
中图分类号
学科分类号
摘要
This chapter analyzes the lightning performance of 500-kV-double-circuit transmission lines by the Alternative Transient Performance-Electromagnetic Transient Program (ATP-EMTP). With towers using the multi-wave impedance model and eliminating voltage reflection on the lines by a matching resistor, a simulation method has been established to evaluate the factors that may influence the backflashover voltage such as tower height, tower footing resistance, and conductor phase arrangements. A statistical method is presented to calculate the line trip-out rates due to back-flashover. The results show that the impact of phase arrangements on the back-flashover trip-out rate of a single-circuit line is little, but significant on the double-circuit lines. © Springer International Publishing Switzerland 2015.
引用
收藏
页码:389 / 397
相关论文
共 50 条
  • [21] Improving tower grounding vs. insulation level to obtain the desired back-flashover rate for HV transmission lines
    Asadpourahmadchali, Mohammadbagher
    Niasati, Mohsen
    Alinejad-Beromi, Yousef
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 123
  • [22] Electromagnetic Environmental Impact of 500-kV Double -Circuit Transmission Lines
    Qi Jianzhao
    Electricity, 2011, 22 (01) : 24 - 28
  • [23] Lightning protection performance of 500 kV quadruple-circuit transmission lines on the same tower
    School of Electrical Engineering, Wuhan University, Wuhan 430072, China
    Gaodianya Jishu, 2008, 1 (168-171):
  • [24] ANALYSIS OF LIGHTNING DATA FOR BACK FLASHOVER PREVENTION IN 69 KV OVERHEAD TRANSMISSION LINE IN TAIWAN
    Chang, Chien-Kuo
    Ke, Hung-Yu
    Wu, Ruay-Nan
    Journal of Technology, 2022, 37 (02): : 137 - 148
  • [25] Flashover Performance Test with Lightning Impulse and Simulation Analysis of Different Insulators in a 110 kV Double-Circuit Transmission Tower
    Zhang, Yaqi
    Li, Licheng
    Han, Yongxia
    Ruan, Yaoxuan
    Yang, Jie
    Cai, Hansheng
    Liu, Gang
    Zhang, Yi
    Jia, Lei
    Ma, Yutang
    ENERGIES, 2018, 11 (03):
  • [26] Influence of Lightning Flashover Criterion on the Calculated Lightning withstand Level of ±800kV UHVDC Transmission Lines at High Altitude
    Han, Yongxia
    Tang, Li
    Li, Licheng
    He, Qiuping
    Hao, Yanpeng
    Yao, Senjing
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 185 - 191
  • [27] Probability parameter estimation of outage rate effects for lightning overvoltage analysis on 500 kV EHV double circuit transmission lines using neural networks
    Jaipradidtham, C.
    IPEC: 2005 INTERNATIONAL POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2005, : 803 - 808
  • [28] Lightning performances for AC 500kV transmission lines with quadruple-circuit on single tower
    Chai, Yajing
    Zhou, Wenjun
    Xue, Li
    Liu, Xiaodong
    Su, Hongmei
    2007 COMPATIBILITY IN POWER ELECTRONICS, 2007, : 83 - 88
  • [29] Influence of AC transmission lines on parallelly erected ±500 kV HVDC double circuit transmission lines and suppression measure
    Li, Tao
    Li, Xin-Nian
    Jiang, Wei-Ping
    Gao, Jian
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (19): : 70 - 75
  • [30] Analysis of lightning-induced current and voltages on 500 kV EHV double circuit transmission lines of type DL3° andd DT 20° in lightning protection system
    Jaipradidtham, C
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C385 - C388