Analysis of Dried Blood Spots for Polychlorinated Biphenyls and Organochlorine Pesticides by Gas Chromatography Coupled with Tandem Mass Spectrometry

被引:5
|
作者
Provatas, Anthony A. [1 ]
Kolakowski, Steven L. [1 ]
Sternberg, Francis H. [1 ]
Stuart, James D. [1 ,2 ]
Perkins, Christopher R. [1 ]
机构
[1] Univ Connecticut, Ctr Environm Sci & Engn, 3107 Horsebarn Hill Rd,Unit 4210, Storrs, CT 06269 USA
[2] Univ Connecticut, Dept Chem, Storrs, CT USA
关键词
Dried blood spots; gas chromatography; tandem mass spectrometry; organochlorine pesticides; polychlorinated biphenyls; PERSISTENT ORGANIC POLLUTANTS; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYCYCLIC AROMATIC-HYDROCARBONS; PCB METABOLITES; HEALTH; POLLUTION; FISH;
D O I
10.1080/00032719.2018.1541994
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCs) are anthropogenic pollutants highly resistant to chemical degradation and readily absorbed by organic tissue. Their persistence in the environment and toxicological threat to mammals prompts swift, reliable methods of analysis. This study outlines a rapid, efficient and sensitive, validated methodology utilizing a simple liquid extraction technique, and subsequent analysis by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) for the determination of PCBs and OCs from dried blood spots. The PCBs and OCs were quantified in whole marine mammal blood spotted on Whatman Protein Saver cards (PSCs) by extracting the analytes into acetonitrile acidified with formic acid, followed by GC-MS/MS analysis. The samples were analyzed in positive electron impact (EI+) ionization mode with the electron energy set to 40 eV to preserve analyte integrity. Fortified blood with the analytes of interest was used for method validation and subsequent sample screening. The recoveries of targeted analytes ranged from 62.5% to 107.8%, with relative standard deviations ranging from 0.09% to 4.6% at a 100 ng center dot mL(-1) concentration level. The method detection limits were from 40.4 ng center dot g(-1) to 179.2 ng center dot g(-1) for the PCBs and 37.6 ng center dot g(-1) to 145.1 ng center dot g(-1) for the OCs. The use of dried blood spots provided for numerous advantages compared to whole blood samples while demonstrating reduced matrix effects and enhanced sample lifespan while retaining analyte sensitivity.
引用
收藏
页码:1379 / 1395
页数:17
相关论文
共 50 条
  • [41] Determination of Synacthen® in dried blood spots for doping control analysis using liquid chromatography tandem mass spectrometry
    Laura Tretzel
    Andreas Thomas
    Hans Geyer
    Philippe Delahaut
    Wilhelm Schänzer
    Mario Thevis
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4709 - 4720
  • [42] Determination of remifentanil in neonatal dried blood spots by liquid chromatography-tandem mass spectrometry
    Trontelj, Jurij
    Rozman, Ales
    Mrhar, Ales
    ACTA PHARMACEUTICA, 2024, 74 (02) : 343 - 354
  • [43] Determination of homocysteine in dried blood spots using liquid chromatography-tandem mass spectrometry
    Han Jichun
    Li Guanglin
    Wang Xiaochen
    Luo Yiqi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2016, 34 (06) : 567 - 571
  • [44] Detection of everolimus from dried blood spots using liquid chromatography tandem mass spectrometry
    Boyd, Jessica
    Sadrzadeh, S. M. Hossein
    CLINICAL BIOCHEMISTRY, 2015, 48 (15) : 1016 - 1016
  • [45] Trace-level analysis of polychlorinated biphenyls, organochlorine pesticides and polycyclic aromatic hydrocarbons in human plasma or serum by dispersive liquid-liquid microextraction and gas chromatography-tandem mass spectrometry
    Shin, Ho-Sang
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (06)
  • [46] Determination of Indicator Congeners of Polychlorinated Biphenyls in Water at Ultratrace Levels by Gas Chromatography–Tandem Mass Spectrometry
    O. V. Kustova
    A. S. Stepanov
    A. G. Gorshkov
    Journal of Analytical Chemistry, 2021, 76 : 1336 - 1344
  • [47] Development of a method for multiple vitamin D metabolite measurements by liquid chromatography coupled with tandem mass spectrometry in dried blood spots
    Rola, R.
    Kowalski, K.
    Bienkowski, T.
    Kolodynska-Goworek, A.
    Studzinska, S.
    ANALYST, 2019, 144 (01) : 299 - 309
  • [48] Evaluation of gas chromatography-atmospheric pressure chemical ionization tandem mass spectrometry as an alternative to gas chromatography tandem mass spectrometry for the determination of polychlorinated biphenyls and polybrominated diphenyl ethers
    Fang, Jing
    Zhao, Hongzhi
    Zhang, Yanhao
    Wong, Minghung
    He, Yu
    Sun, Qianqian
    Xu, Shunqing
    Cai, Zongwei
    CHEMOSPHERE, 2019, 225 : 288 - 294
  • [49] Evaluation of gas chromatography-tandem quadrupole mass spectrometry for the determination of organochlorine pesticides in fats and oils
    Patel, K
    Fussell, RJ
    Hetmanski, M
    Goodall, DM
    Keely, BJ
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1068 (02) : 289 - 296
  • [50] Estimation of measurement uncertainty of polychlorinated biphenyls, polycyclic aromatic hydrocarbons and organochlorine pesticides in the atmosphere using gas chromatography-mass spectrometry and gas chromatography-electron capture detector
    Aslan-Sungur, Guler
    Gaga, Eftade O.
    Yenisoy-Karakas, Serpil
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1325 : 40 - 48