Analysis of Dried Blood Spots for Polychlorinated Biphenyls and Organochlorine Pesticides by Gas Chromatography Coupled with Tandem Mass Spectrometry

被引:5
|
作者
Provatas, Anthony A. [1 ]
Kolakowski, Steven L. [1 ]
Sternberg, Francis H. [1 ]
Stuart, James D. [1 ,2 ]
Perkins, Christopher R. [1 ]
机构
[1] Univ Connecticut, Ctr Environm Sci & Engn, 3107 Horsebarn Hill Rd,Unit 4210, Storrs, CT 06269 USA
[2] Univ Connecticut, Dept Chem, Storrs, CT USA
关键词
Dried blood spots; gas chromatography; tandem mass spectrometry; organochlorine pesticides; polychlorinated biphenyls; PERSISTENT ORGANIC POLLUTANTS; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYCYCLIC AROMATIC-HYDROCARBONS; PCB METABOLITES; HEALTH; POLLUTION; FISH;
D O I
10.1080/00032719.2018.1541994
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCs) are anthropogenic pollutants highly resistant to chemical degradation and readily absorbed by organic tissue. Their persistence in the environment and toxicological threat to mammals prompts swift, reliable methods of analysis. This study outlines a rapid, efficient and sensitive, validated methodology utilizing a simple liquid extraction technique, and subsequent analysis by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) for the determination of PCBs and OCs from dried blood spots. The PCBs and OCs were quantified in whole marine mammal blood spotted on Whatman Protein Saver cards (PSCs) by extracting the analytes into acetonitrile acidified with formic acid, followed by GC-MS/MS analysis. The samples were analyzed in positive electron impact (EI+) ionization mode with the electron energy set to 40 eV to preserve analyte integrity. Fortified blood with the analytes of interest was used for method validation and subsequent sample screening. The recoveries of targeted analytes ranged from 62.5% to 107.8%, with relative standard deviations ranging from 0.09% to 4.6% at a 100 ng center dot mL(-1) concentration level. The method detection limits were from 40.4 ng center dot g(-1) to 179.2 ng center dot g(-1) for the PCBs and 37.6 ng center dot g(-1) to 145.1 ng center dot g(-1) for the OCs. The use of dried blood spots provided for numerous advantages compared to whole blood samples while demonstrating reduced matrix effects and enhanced sample lifespan while retaining analyte sensitivity.
引用
收藏
页码:1379 / 1395
页数:17
相关论文
共 50 条
  • [31] Determination of Hydroxylated Polychlorinated Biphenyls in Mouse Tissues and Blood by Gas Chromatography/Mass Spectrometry
    Shi Yong-Fu
    Lin Hong
    Huang Dong-Mei
    Gong Qian
    Cai You-Qiong
    Wang Yuan
    Qian Bei-Lei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (09) : 1345 - 1348
  • [32] ROUTINE DETERMINATION OF ORGANOCHLORINE PESTICIDES AND POLYCHLORINATED-BIPHENYLS IN HUMAN-MILK USING CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    SEYMOUR, MP
    JEFFERIES, TM
    FLOYD, AJ
    NOTARIANNI, LJ
    ANALYST, 1987, 112 (04) : 427 - 431
  • [33] Identification of inherited disorders by tandem mass spectrometry analysis of dried blood spots
    Chernonosov, A.
    Alekseeva, I.
    Fedorova, O.
    FEBS JOURNAL, 2013, 280 : 278 - 278
  • [34] Performance of atmospheric pressure gas chromatography-tandem mass spectrometry for the analysis of organochlorine pesticides in human serum
    Jing Fang
    Hongzhi Zhao
    Yanhao Zhang
    Yu He
    Qianqian Sun
    Shunqing Xu
    Zongwei Cai
    Analytical and Bioanalytical Chemistry, 2019, 411 : 4185 - 4191
  • [35] Performance of atmospheric pressure gas chromatography-tandem mass spectrometry for the analysis of organochlorine pesticides in human serum
    Fang, Jing
    Zhao, Hongzhi
    Zhang, Yanhao
    He, Yu
    Sun, Qianqian
    Xu, Shunqing
    Cai, Zongwei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (18) : 4185 - 4191
  • [36] Analysis of cotinine in dried blood spots by LC APCI tandem mass spectrometry
    Sosnoff, Connie S.
    Bernert, John T.
    CLINICA CHIMICA ACTA, 2008, 388 (1-2) : 228 - 229
  • [37] Analysis of organochlorine pesticides in wine by solvent bar microextraction coupled with gas chromatography with tandem mass spectrometric detection
    Chia, KJ
    Huang, SD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (02) : 118 - 124
  • [38] Determination of SynacthenA® in dried blood spots for doping control analysis using liquid chromatography tandem mass spectrometry
    Tretzel, Laura
    Thomas, Andreas
    Geyer, Hans
    Delahaut, Philippe
    Schaenzer, Wilhelm
    Thevis, Mario
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (16) : 4709 - 4720
  • [39] The performance of atmospheric pressure gas chromatography-tandem mass spectrometry compared to gas chromatography-high resolution mass spectrometry for the analysis of polychlorinated dioxins and polychlorinated biphenyls in food and feed samples
    ten Dam, Guillaume
    Pussente, Igor Cabreira
    Scholl, Georges
    Eppe, Gauthier
    Schaechtele, Alexander
    van Leeuwen, Stefan
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1477 : 76 - 90
  • [40] Analysis of benzoylecgonine in dried blood spots by liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry
    Sosnoff, CS
    Ann, QH
    Bernert, JT
    Powell, MK
    Miller, BB
    Henderson, LO
    Hannon, WH
    Fernhoff, P
    Sampson, EJ
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (03) : 179 - 184