Graphical and statistical analyses of the oculocardiac reflex during a non-invasive intracranial pressure measurement

被引:4
|
作者
Hamarat, Yasin [1 ]
Bartusis, Laimonas [1 ]
Deimantavicius, Mantas [1 ]
Siaudvytyte, Lina [2 ]
Januleviciene, Ingrida [2 ]
Ragauskas, Arminas [1 ]
Bershad, Eric M. [3 ]
Fandino, Javier [4 ]
Kienzler, Jenny [4 ]
Remonda, Elke [4 ]
Matijosaitis, Vaidas [5 ]
Rastenyte, Daiva [5 ]
Petrikonis, Kestutis [5 ]
Berskiene, Kristina [6 ]
Zakelis, Rolandas [1 ]
机构
[1] Kaunas Univ Technol, Hlth Telemat Sci Inst, Kaunas, Lithuania
[2] Lithuanian Univ Hlth Sci, Eye Clin, Kaunas, Lithuania
[3] Baylor Coll Med, Dept Neurol, Houston, TX 77030 USA
[4] Kantonsspital Aarau, Dept Neurosurg, Aarau, Switzerland
[5] Lithuanian Univ Hlth Sci, Dept Neurol, Kaunas, Lithuania
[6] Lithuanian Univ Hlth Sci, Sports Inst, Kaunas, Lithuania
来源
PLOS ONE | 2018年 / 13卷 / 04期
关键词
TRIGEMINO-CARDIAC REFLEX; HEART-RATE-VARIABILITY; STRABISMUS SURGERY; ADJUSTABLE SUTURES; ANESTHESIA; KNOWLEDGE; CHILDREN; ADULTS; DEPTH;
D O I
10.1371/journal.pone.0196155
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose This study aimed to examine the incidence of the oculocardiac reflex during a non-invasive intracranial pressure measurement when gradual external pressure was applied to the orbital tissues and eye. Methods Patients (n = 101) and healthy volunteers (n = 56) aged 20-75 years who underwent a non-invasive intracranial pressure measurement were included in this retrospective oculocardiac reflex analysis. Prespecified thresholds greater than a 10% or 20% decrease in the heart rate from baseline were used to determine the incidence of the oculocardiac reflex. Results None of the subjects had a greater than 20% decrease in heart rate from baseline. Four subjects had a greater than 10% decrease in heart rate from baseline, representing 0.9% of the total pressure steps. Three of these subjects were healthy volunteers, and one was a glaucoma patient. Conclusion The incidence of the oculocardiac reflex during a non-invasive intracranial pressure measurement procedure was very low and not associated with any clinically relevant effects.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Non-invasive Methods of Estimating Intracranial Pressure
    Jamie B. Rosenberg
    Ariel L. Shiloh
    Richard H. Savel
    Lewis A. Eisen
    Neurocritical Care, 2011, 15 : 599 - 608
  • [22] NEW METHOD OF NON-INVASIVE MEASUREMENT OF INTRACRANIAL-PRESSURE (ICP) IN NEWBORNS
    PEABODY, J
    FALLENSTEIN, F
    DUC, G
    HUCH, R
    HUCH, A
    CLINICAL RESEARCH, 1980, 28 (01): : A125 - A125
  • [23] Ophthalmic Artery as a Sensor for Non-invasive Intracranial Pressure Measurement Electronic System
    Bartusis, L.
    Zakelis, R.
    Daubaris, G.
    Ragauskas, A.
    Rutkauskas, S.
    Matijosaitis, V.
    Preiksaitis, A.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2012, 122 (06) : 45 - 48
  • [24] A Review of the Methods of Non-Invasive Assessment of Intracranial Pressure through Ocular Measurement
    Dong, Jinhui
    Li, Qi
    Wang, Xiaofei
    Fan, Yubo
    BIOENGINEERING-BASEL, 2022, 9 (07):
  • [25] MECHANICAL APLANATION TONOMETER FOR NON-INVASIVE MEASUREMENT OF INTRACRANIAL-PRESSURE IN INFANTS
    BOSTON, VE
    HOFMANN, DA
    SCOTT, JES
    ZEITSCHRIFT FUR KINDERCHIRURGIE UND GRENZGEBIETE, 1976, 19 (02): : 121 - 128
  • [26] Non-invasive measurement of intracranial pressure in neonates and infants: Experience with the Rotterdam teletransducer
    Wayenberg, JL
    INTRACRANIAL PRESSURE AND NEUROMONITORING IN BRAIN INJURY, 1998, 71 : 70 - 73
  • [27] NEW DEVICE FOR NON-INVASIVE MEASUREMENT OF INTRACRANIAL-PRESSURE (ICP) IN NEWBORNS
    HUCH, A
    FALLENSTEIN, F
    HUCH, R
    PEABODY, JL
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1979, 6 (04) : 185 - 187
  • [28] Innovative non-invasive method for absolute intracranial pressure measurement without calibration
    Ragauskas, A
    Daubaris, G
    Dziugys, A
    Azelis, V
    Gedrimas, V
    Intracranial Pressure and Brain Monitoring XII, 2005, 95 : 357 - 361
  • [29] Intracranial pressure: a comparison of the non-invasive HeadSense monitor vs. lumbar pressure measurement
    Hvedstrup, Jeppe
    Radojicic, Aleksandra
    Moudrou, Walid
    Herklots, Martin W.
    Wert, Anton
    Holzgraefe, Manfred
    Obermann, Mark
    Schoonman, Guus G.
    Jensen, Rigmor H.
    Schytz, Henrik W.
    JOURNAL OF HEADACHE AND PAIN, 2018, 19
  • [30] NON-INVASIVE MEASUREMENT OF VENTRICULAR PRESSURE
    SOUTHON, FCG
    AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (03): : 592 - 592