Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles

被引:38
|
作者
Yin, Guang [1 ,2 ]
Xing, Ling [2 ]
Ma, Xiu-Ju [2 ]
Wan, Jun [1 ]
机构
[1] Coll Environm & Safety Engn, Key Lab Ecochem Engn, Minist Educ, Qingdao 266042, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
来源
CHEMICAL PAPERS | 2014年 / 68卷 / 04期
基金
中国国家自然科学基金;
关键词
hydrogen peroxide; platinum nanoparticles; nanoporous gold; electrodeposition; enzyme-free; amperometric sensor; HORSERADISH-PEROXIDASE; ELECTROCHEMICAL SENSOR; AMPEROMETRIC BIOSENSOR; OXIDATIVE STRESS; CARBON NANOTUBES; IMMOBILIZATION; ACETYLCHOLINE; NANOCOMPOSITE; PESTICIDES; COLLOIDS;
D O I
10.2478/s11696-013-0473-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel non-enzymatic electrochemical sensor based on a nanoporous gold electrode modified with platinum nanoparticles was constructed for the determination of hydrogen peroxide (H2O2). Platinum nanoparticles exhibit good electrocatalytic activity towards hydrogen peroxide. The nanoporous gold (NPG) increases the effective surface area and has the capacity to promote electron-transfer reactions. With electrodeposition of Pt nanoparticles (NPs) on the surface of the nanoporous gold, the modified Au electrode afforded a fast, sensitive and selective electrochemical method for the determination of H2O2. The linear range for the detection of H2O2 was from 1.0 x 10(-7) M to 2.0 x 10(-5) M while the calculated limit of detection was 7.2 x 10(-8) M on the basis of the 3 sigma/slope (sigma represents the standard deviation of the blank samples). These findings could lead to the widespread use of electrochemical sensors to detect H2O2.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [31] A novel non-enzymatic hydrogen peroxide sensor based on Co:ZnO modified electrodes
    Wang, Long
    Wu, Tong
    Wu, Han
    Zhong, Jun
    Wang, Ning
    Wang, Rongming
    [J]. PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2018, 28 (01) : 24 - 27
  • [32] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [33] Non-enzymatic hydrogen peroxide sensor based on palladium-decorated poly(thionine) modified glassy carbon electrode
    Celebi, Mutlu Sonmez
    Kara, Songul Kirlak
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2024, 71 (05) : 482 - 492
  • [34] Non-enzymatic hydrogen peroxide sensor based on MnO2-ordered mesoporous carbon composite modified electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Zhang, Zhao
    Ding, Yaping
    Deng, Dongmei
    [J]. ELECTROCHIMICA ACTA, 2012, 77 : 179 - 183
  • [35] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosan‐encapsulated graphite and platinum nanoparticles
    Tse-Wei Chen
    Selvakumar Palanisamy
    Shen-Ming Chen
    [J]. Microchimica Acta, 2016, 183 : 2861 - 2869
  • [36] Non-Enzymatic Glucose Sensor based on Electrodeposition of Platinum Particles on Polyaniline Modified Pt Electrode
    Malhotra, Shveta
    Tang, Yijun
    Varshney, Pradeep K.
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 699 - 715
  • [37] Amperometric non-enzymatic bimetallic glucose sensor based on platinum tellurium microtubes modified electrode
    Guascito, Maria Rachele
    Chirizzi, Daniela
    Malitesta, Cosimino
    Siciliano, Maria
    Siciliano, Tiziana
    Tepore, Antonio
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2012, 22 : 45 - 48
  • [38] Gold nanoparticles for sensitive detection of hydrogen peroxide: a simple non-enzymatic approach
    J. Sophia
    G. Muralidharan
    [J]. Journal of Applied Electrochemistry, 2015, 45 : 963 - 971
  • [39] Gold nanoparticles for sensitive detection of hydrogen peroxide: a simple non-enzymatic approach
    Sophia, J.
    Muralidharan, G.
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2015, 45 (09) : 963 - 971
  • [40] Electroless deposition of Gold-Platinum Core@Shell Nanoparticles on Glassy Carbon Electrode for Non-Enzymatic Hydrogen Peroxide sensing#
    N S K GOWTHAMAN
    S ABRAHAM JOHN
    [J]. Journal of Chemical Sciences, 2016, 128 : 331 - 338