Implementation of Arc-Flash Protection Using IEC 61850 Goose Messaging

被引:0
|
作者
Cabrera, Charina [1 ]
Chiu, Stephen [1 ]
Nair, Nirmal Kumar C. [2 ]
机构
[1] PowerCo Ltd, New Plymouth, England
[2] Univ Aukland, Dept Elect & Comp Engn, Auckland, New Zealand
关键词
Distribution; Bus protection; IEC; 61850; Arc-Flash Protection; Intelligent Electronic Devices (IEDs);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Timely bus protection is extremely critical due to the widespread instability of the power system that can occur due to a bus fault. In addition to existing conventional ways of 11 kV bus protection a newer possibility of arc-flash protection using IEC 61850 generic object oriented substation event (GOOSE) messaging is now possible. Arc-flash protection has both high selectivity and security and relatively it costs less with other comparable schemes. This paper describes the design and implementation of Arc-Flash Protection using IEC 61850 based GOOSE messaging at a real substation in New Zealand. Further development and application of this form of 11 kV bus protection happening in Powerco will also be discussed.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] IEC 61850: Goose Messaging Implementation for MPR
    Shingate, Hemalata M.
    Unnikrishnan, Srija
    Rao, Sudarshan
    ADVANCES IN COMPUTING, COMMUNICATION AND CONTROL, 2011, 125 : 214 - +
  • [2] Towards Implementation of IEC 61850 GOOSE Messaging in IEC 61499 Environment
    Xu, Jiang
    Yang, Chen-Wei
    Zhabelova, Gulnara
    Berber, Stevan
    Vyatkin, Valeriy
    2013 11TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL INFORMATICS (INDIN), 2013, : 464 - 470
  • [3] Experimenting with IEC 61850 and GOOSE messaging
    Amulya
    Patil, Mayur
    Bhide, S. R.
    Bhat, S. S.
    2017 4TH INTERNATIONAL CONFERENCE ON POWER, CONTROL & EMBEDDED SYSTEMS (ICPCES), 2017,
  • [4] IEC 61850 Testing and Commissioning Advantages Using GOOSE Messaging
    Riccardo, Antonio, Jr.
    2019 72ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2019,
  • [5] Implementation of Automatic Bus Transfer Scheme Using Multifunction Numerical Protection Relay IEDs on IEC 61850 GOOSE Messaging
    Sahoo, Binaya Kumar
    Mehtani, Moksh
    2018 4TH INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2018,
  • [6] Towards Implementation of IEC 61850 GOOSE Messaging in Event-Driven IEC 61499 Environment
    Yang, Chen-Wei
    Xu, Jiang
    Vyatkin, Valeriy
    2014 IEEE EMERGING TECHNOLOGY AND FACTORY AUTOMATION (ETFA), 2014,
  • [7] Reverse Interlocking Protection using IEC 61850 GOOSE
    Daboul, Mayada
    Orsagova, Jaroslava
    PROCEEDINGS OF THE 9TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2017), 2017, : 665 - 669
  • [8] Using IEC 61850 GOOSE messages in microgrid protection
    Gu, Jyh-Cherng
    Liu, Chun-Hung
    Wang, Jing-Min
    Yang, Ming-Ta
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (12):
  • [9] Improvement in Arc Flash Protection Based on IEC 61850 Protocol
    Kumar, Shantanu
    Abu-Siada, Ahmed
    Das, Narottam
    Islam, Syed
    2023 33RD AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE, AUPEC, 2023,
  • [10] Safety related functions with IEC 61850 GOOSE messaging
    Magro, Micaela Caserza
    Pinceti, Paolo
    Rocca, Luca
    Rossi, Giorgio
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 104 : 515 - 523