Implementation of Arc-Flash Protection Using IEC 61850 Goose Messaging

被引:0
|
作者
Cabrera, Charina [1 ]
Chiu, Stephen [1 ]
Nair, Nirmal Kumar C. [2 ]
机构
[1] PowerCo Ltd, New Plymouth, England
[2] Univ Aukland, Dept Elect & Comp Engn, Auckland, New Zealand
关键词
Distribution; Bus protection; IEC; 61850; Arc-Flash Protection; Intelligent Electronic Devices (IEDs);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Timely bus protection is extremely critical due to the widespread instability of the power system that can occur due to a bus fault. In addition to existing conventional ways of 11 kV bus protection a newer possibility of arc-flash protection using IEC 61850 generic object oriented substation event (GOOSE) messaging is now possible. Arc-flash protection has both high selectivity and security and relatively it costs less with other comparable schemes. This paper describes the design and implementation of Arc-Flash Protection using IEC 61850 based GOOSE messaging at a real substation in New Zealand. Further development and application of this form of 11 kV bus protection happening in Powerco will also be discussed.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] IEC61850: Implementation in new Generation of Electrical Protection
    Jirickova, Jana
    PROCEEDINGS OF THE IVTH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRIC POWER ENGINEERING - ELEKTROENERGETIKA 2007, 2007, : 471 - 473
  • [32] Implementation of IEC 61850 power protection tester in Linux environment
    Kurek, K.
    Nogal, L.
    Kowalik, R.
    Januszewski, M.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2020, 68 (04) : 689 - 696
  • [33] Applying Intelligent Fast Load Shed Using IEC 61850 GOOSE
    Theron, J. C.
    Wilsey, Troy
    Colonnese, Anthony
    Gagner, Russell
    2018 71ST ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2018,
  • [34] ARC-FLASH PROTECTION FOR LOW- AND MEDIUM-VOLTAGE PANELS
    Rocha, Geraldo
    Zanirato, Eduardo
    Ayello, Fernando
    Taninaga, Roberto
    2011 RECORD OF CONFERENCE PAPERS INDUSTRY APPLICATIONS SOCIETY 58TH ANNUAL IEEE PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE (PCIC), 2011,
  • [35] On the Implementation and Security Analysis of Routable-GOOSE Messages Based on IEC 61850 Standard
    Kharchouf, Ibtissam
    Alrashide, Abdulmeen
    Abdelrahman, Mahmoud S.
    Mohammed, Osama A.
    2022 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2022 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2022,
  • [36] Adaptive Breaker Failure Protection Scheme for Double Busbar Substation using IEC 61850 GOOSE Message Communication
    Noran, Mohd Noorfazly
    Shukri, Zainoren
    2ND INTERNATIONAL SYMPOSIUM ISTMET 2015 TECHNOLOGY MANAGEMENT & EMERGING TECHNOLOGIES, 2015,
  • [37] Decentralized fault location, isolation and self restoration (FLISR) logic implementation using IEC 61850 GOOSE signals
    Bielenica, Pawel
    Widzinska, Joanna
    Lukaszewski, Artur
    Nogal, Lukasz
    Lukaszewski, Piotr
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2022, 70 (05)
  • [38] Implementation of accelerated transmission line protection schemes in substations with IEC 61850
    Apostolov, A. P.
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1050 - 1055
  • [39] Design and Implementation of IEC 61850 in Communication-Assisted Protection Strategy
    Sun, Wei
    Chambers, Reece
    Kleinjan, Ryan
    Nelson, Jeremy
    Hietpas, Steven
    Johnson, Rick
    Johnson, Toby
    Strube, Todd
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [40] Review of Bus Differential Protection Using IEC 61850
    Lima, Diomar A. C.
    Bernardon, Daniel P.
    Morais, Adriano P.
    Oliveira, Aecio L.
    Hokama, Wagner S.
    Conceicao, Julia B. R.
    Sartori, Angelo F.
    ENERGIES, 2022, 15 (24)