Liver fibrosis evaluation using real-time shear wave elastography: Applicability and diagnostic performance using methods without a gold standard

被引:136
|
作者
Poynard, Thierry [1 ]
Munteanu, Mona [2 ]
Luckina, Elena [1 ,3 ]
Perazzo, Hugo [1 ]
Ngo, Yen [1 ]
Royer, Luca [1 ]
Fedchuk, Larysa [1 ]
Sattonnet, Florence [1 ]
Pais, Raluca [1 ]
Lebray, Pascal [1 ]
Rudler, Marika [1 ]
Thabut, Dominique [1 ]
Ratziu, Vlad [1 ]
机构
[1] APHP UPMC Liver Ctr, F-75651 Paris 13, France
[2] BioPredictive, Res Unit, Paris, France
[3] ANRS, Paris, France
关键词
Fibrosis; Obuchowski measure; Concordance; FibroTest; FibroSure; FibroScan; Aixplorer; Non-invasive methods; STIFFNESS MEASUREMENT; HEPATITIS-C; ACCURACY; FIBROTEST; BIOPSY;
D O I
10.1016/j.jhep.2012.12.021
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & Aims: Real-time shear wave elastography (SWE) is a new two-dimensional transient elastography which had no assessment of factors associated with reliability, and had limited comparisons with other validated fibrosis biomarkers. The aim was to assess the applicability and performances of SWE for the diagnosis of fibrosis as compared with FibroTest (FT) and liver stiffness measurement (LSM) by transient elastography using two probes (TE-M and TE-XL). Methods: Without a gold standard, the strength of concordance, discordance analysis and latent class analysis (LCM) were applied. Results: 422 patients were included. The applicability of SWE (90.0%) was significantly lower than that of FT (97.9%; p <0.0001) and did not differ from those of TE-M (90.5%) and TE-XL (90.3%); it was higher though for SWE (86%) in 22 patients with ascites vs. 55% using TE-M (p = 0.04). For the diagnosis of all fibrosis stages as presumed by FT, the performance of SWE was highly significant (Obuchowski measure 0.807 +/- 0.013 [m +/- se]), but lower than those of TE-M (0.852; p = 0.0007) and TE-XL (0.834; p = 0.046). SWE had a low performance for discrimination between F0 and F1. For the diagnosis of cirrhosis using LCM, SWE specificities were all equal to 99%, and SWE sensitivities ranged from 0.47 to 0.64. For the diagnosis of non-cirrhotic stages, the results were heterogeneous. Conclusions: The performance of SWE for the diagnosis of cirrhosis was similar to those of FT and TE. SWE applicability was lower than that of FT, but greater than that of TE in patients with ascites. (c) 2013 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:928 / 935
页数:8
相关论文
共 50 条
  • [21] Determination of Normal Skin Elasticity by Using Real-time Shear Wave Elastography
    Yang, Yujia
    Wang, Liyun
    Yan, Feng
    Xiang, Xi
    Tang, Yuanjiao
    Zhang, Lingyan
    Liu, Jibin
    Qiu, Li
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (11) : 2507 - 2516
  • [22] Real-time ultrasound shear wave elastography using a local phase gradient
    Gonzalez-Mateo, Enrique
    Camarena, Francisco
    Jimenez, Noe
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2025, 260
  • [23] Utility of real-time shear wave elastography for assessing liver fibrosis in patients with chronic hepatitis C infection without cirrhosis: Comparison of liver fibrosis indices
    Tada, Toshifumi
    Kumada, Takashi
    Toyoda, Hidenori
    Ito, Takanori
    Sone, Yasuhiro
    Okuda, Seiji
    Tsuji, Nozomi
    Imayoshi, Yumi
    Yasuda, Eisuke
    HEPATOLOGY RESEARCH, 2015, 45 (10) : E122 - E129
  • [24] Open questions in the assessment of liver fibrosis using real-time elastography - Reply
    Saftoiu, Adrian
    Gheonea, Dan Ionut
    Ciurea, Tudorel
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (06) : W372 - W373
  • [25] Liver fibrosis grading using multiresolution histogram information in real-time elastography
    Albouy-Kissi, A.
    Sarry, L.
    Massoulier, S.
    Bonny, C.
    Randl, K.
    Abergel, A.
    MEDICAL IMAGING 2010: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2010, 7629
  • [26] Non-Invasive Evaluation of Liver Fibrosis by Using Real Time Elastography
    Ozturker, Coskun
    Karagoz, Ergenekon
    Sonmez, Guner
    EUROPEAN JOURNAL OF GENERAL MEDICINE, 2015, 12 (04): : 370 - 370
  • [27] Comparison of the diagnostic performance of Real time tissue elastography as strain elastography with that of FibroScan as shear wave elastography
    Morikawa, Hiroyasu
    Uchida, Sawako K.
    Fujii, Hideki
    Hagihara, Atsushi
    Kawamura, Etsushi
    Iwai, Shuji
    Enomoto, Masaru
    Murakami, Yoshiki
    Tamori, Akihiro
    Kawada, Norifumi
    HEPATOLOGY, 2013, 58 : 955A - 955A
  • [28] PERFORMANCE OF REAL-TIME ELASTOGRAPHY AND TRANSIENT ELASTOGRAPHY IN THE ASSESSMENT OF LIVER FIBROSIS IN CHRONIC HEPATITIS
    Ferraioli, Giovanna
    Tinelli, Carmine
    Dal Bello, Barbara
    Calderon, Willy
    Lissandrin, Raffaella
    Filice, Carlo
    HEPATOLOGY, 2011, 54 : 816A - 816A
  • [29] How the measurement depth influences the liver stiffness assessment using real-time shear wave elastography (SWE)
    Wang, Cong-zhi
    Xiao, Yang
    Song, Dan
    Ming, Yan
    Zheng, Hai-rong
    Zheng, Jian
    Zeng, Jie
    Huang, Ze-ping
    Zheng, Rong-qin
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 13 - 16
  • [30] Diagnostic Value of Real-Time Shear Wave Elastography in Diagnosing Thyroid Cancer
    Oprea, Maria Cristina
    Vlad, Mihaela
    Golu, Ioana
    Sporea, Ioan
    Fulger, Lazar
    REVISTA DE CHIMIE, 2017, 68 (12): : 2818 - 2822