Analysis of large scale tests for AP-600 passive containment cooling system

被引:0
|
作者
Sha, WT [1 ]
Chien, TH [1 ]
Sun, JG [1 ]
Chao, BT [1 ]
机构
[1] ANL E, Argonne, IL 60439 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
All next-generation light water reactors utilize passive systems to remove heat via natural circulation and are significantly different from past and current nuclear plant designs. One unique feature of the AP-600 is its passive containment cooling system (PCCS), which is designed to maintain containment pressure below the design limit for 72 hours without action by the reactor operator. During a design-basis accident, i.e., either a loss-of-coolant or a main steam-line break accident, steam escapes and comes in contact with the much cooler containment vessel wall. Heat is transfer ren to the inside surface of the steel containment wall by convection and condensation of steam and through the containment steel wall by conduction. Heat is then transferred from the outside of the containment surface by heating and evaporation of a thin liquid film that is formed by applying wafer at the top of the containment vessel dome. Air in the annular space is heated by both convection and injection of steam from the evaporating liquid film. The heated air and vapor rise as a result of natural circulation and exit the shield building through the outlets above the containment shell. All of the analytical models that are developed for and used in the COMMIX-ID code for predicting performance of rite PCCS will be described. These models cover governing conservation equations for multicomponents single phase flow: transport equations for the k-epsilon two-equation turbulence model, auxiliary equations, liquid-film tracking model for both inside (condensate) and outside (evaporating liquid film) surfaces of the containment vessel wall, thermal coupling between flow domains inside and outside the containment vessel, and heat and mass transfer models. Various key parameters of the COMMIX-ID results and corresponding AP-600 PCCS experimental data are compared and the agreement is good. Significant findings from this study are summarized.
引用
收藏
页码:199 / 216
页数:6
相关论文
共 50 条
  • [1] Analysis of large-scale tests, for AP-600 passive containment cooling system
    Sha, WT
    Chien, TH
    Sun, JG
    Chao, B
    NUCLEAR ENGINEERING AND DESIGN, 2004, 232 (02) : 197 - 216
  • [2] AP600 WINS GOOD GRADES IN CONTAINMENT COOLING TESTS
    CASO, CL
    NUCLEAR ENGINEERING INTERNATIONAL, 1992, 38 (460): : 30 - &
  • [3] LARGE SCALE PWR PASSIVE CONTAINMENT COOLING SYSTEM WIND TUNNEL TEST
    Pan Xinxin
    Huang Jingyu
    Song Chunjing
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 2, 2017,
  • [4] THERMAL - HYDRAULIC PERFORMANCE ANALYSIS FOR AP1000 PASSIVE CONTAINMENT COOLING SYSTEM
    Yu, Yu
    Wang, Shengfei
    Niu, Fenglei
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,
  • [5] Conceptual design and analysis of a semi-passive containment cooling system for a large concrete containment
    Byun, CS
    Jerng, DW
    Todreas, NE
    Driscoll, MJ
    NUCLEAR ENGINEERING AND DESIGN, 2000, 199 (03) : 227 - 242
  • [6] Analysis of a passive containment cooling system for NPPs
    Huang, Zheng
    Hedongli Gongcheng/Nuclear Power Engineering, 2014, 35 (06): : 31 - 36
  • [7] AP600 containment cooling plume investigation
    Haessler, RL
    Spencer, DR
    Woodcock, J
    PROCEEDINGS OF THE INTERNATIONAL TOPICAL MEETING ON ADVANCED REACTORS SAFETY, VOLS 1 AND 2, 1997, : 473 - 477
  • [8] Long-term effect analysis of AC600 passive containment cooling system
    Yu, Ji-Yang
    Li, Kun
    Jia, Bao-Shan
    Hedongli Gongcheng/Nuclear Power Engineering, 2002, 23 (03): : 60 - 62
  • [9] Large Scale Pressurized Water Reactor Passive Containment Cooling System Wind Tunnel Test
    Huang Jingyu
    Pan Xinxin
    Song Chunjing
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2019, 5 (03):
  • [10] Simulation of AP1000's passive containment cooling with the German Containment Code System COCOSYS
    Broxtermann, Philipp
    Allelein, Hans-Josef
    NUCLEAR ENGINEERING AND DESIGN, 2013, 261 : 326 - 332