Analysis of a passive containment cooling system for NPPs

被引:0
|
作者
Huang, Zheng [1 ]
机构
[1] China Nuclear Power Engineering Co. Ltd., Beijing,100840, China
来源
关键词
Tanks (containers) - Heat transfer;
D O I
10.13832/j.jnpe.2014.06.0031
中图分类号
学科分类号
摘要
By using RELAP5 and MELCOR, transient behaviors of containment and PCS were investigated. The Influences of various parameters, such as pressure, condenser area and loop height were also studied. The results show that the heat in the containment can be effectively removed by PCS in a period of accident without spray. However the tank water should be made up and cooled for the long run. The heat transfer power of two-phase flow case is always higher, and varies more substantially with pressure, than that of one-phase flow case under the same boundary temperatures. However, flow instability may occur for two-phase flow case. By increasing the condenser area, the heat transfer is enhanced. The influence is less insignificant when the tank temperature is relatively high. It is also found that for both one-phase and two-phase flow, the change of loop height has little effect upon the heat transfer power under the given boundary condition in this study. ©, 2014, Yuan Zi Neng Chuban She. All right reserved.
引用
收藏
页码:31 / 36
相关论文
共 50 条
  • [1] RELIABILITY ANALYSIS FOR PASSIVE CONTAINMENT COOLING SYSTEM IN SEISMIC HAZARD
    Yu, Yu
    Wang, Shengfei
    Lv, Xuefeng
    Niu, Fenglei
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 2, 2012, : 485 - 489
  • [2] Preliminary Study for the Passive Containment Cooling System Analysis of the Advanced PWR
    Yan, Wang
    3RD INTERNATIONAL CONFERENCE ON ASIAN NUCLEAR PROSPECTS (ANUP2012), 2013, 39 : 240 - 247
  • [3] Analysis of the heat transfer capacity of passive containment air cooling system
    Feng Y.
    Wang H.
    Ma Y.
    Li Y.
    Guo Q.
    Yu M.
    Liu Z.
    Han X.
    Yuan Y.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (07): : 1162 - 1168
  • [4] NUMERICAL SIMULATION ANALYSIS ON THE FLOW MECHANISM OF PASSIVE CONTAINMENT COOLING SYSTEM
    Song, Yang
    Li, Wei-Hua
    Li, Sheng-Qiang
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [5] Conceptual design and analysis of a semi-passive containment cooling system for a large concrete containment
    Byun, CS
    Jerng, DW
    Todreas, NE
    Driscoll, MJ
    NUCLEAR ENGINEERING AND DESIGN, 2000, 199 (03) : 227 - 242
  • [6] Theoretical modelling and system response of a passive containment cooling system
    Maheshwari, NK
    Saha, D
    Sinha, RK
    Aritomi, M
    KERNTECHNIK, 2003, 68 (1-2) : 41 - 47
  • [7] THE SENSITIVITY ANALYSIS OF PASSIVE CONTAINMENT COOLING SYSTEM DURING DESIGN BASIS ACCIDENTS
    Zhou, Zhiwei
    Zhang, Yaoli
    Yang, Yanning
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 3, 2012, : 727 - 732
  • [8] Analysis of Wetting Characteristics on Microstructured Hydrophobic Surfaces for the Passive Containment Cooling System
    Zhao, Wei
    Zhang, Xiang
    Tian, Chunlai
    Gao, Zhan
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2015, 2015
  • [9] STUDY ON THE BEHAVIORS OF A CONCEPTUAL PASSIVE CONTAINMENT COOLING SYSTEM
    Wang, Jianjun
    Luo, Beibei
    Guo, Xueqing
    Sun, Zhongning
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,
  • [10] Study on the Behaviors of a Conceptual Passive Containment Cooling System
    Wang, Jianjun
    Guo, Xueqing
    Yu, Shengzhi
    Cai, Baowei
    Sun, Zhongning
    Yan, Changqi
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2014, 2014