By using RELAP5 and MELCOR, transient behaviors of containment and PCS were investigated. The Influences of various parameters, such as pressure, condenser area and loop height were also studied. The results show that the heat in the containment can be effectively removed by PCS in a period of accident without spray. However the tank water should be made up and cooled for the long run. The heat transfer power of two-phase flow case is always higher, and varies more substantially with pressure, than that of one-phase flow case under the same boundary temperatures. However, flow instability may occur for two-phase flow case. By increasing the condenser area, the heat transfer is enhanced. The influence is less insignificant when the tank temperature is relatively high. It is also found that for both one-phase and two-phase flow, the change of loop height has little effect upon the heat transfer power under the given boundary condition in this study. ©, 2014, Yuan Zi Neng Chuban She. All right reserved.
引用
收藏
页码:31 / 36
相关论文
共 50 条
  • [31] Development of a PCCS module in the ATHROC for simulation of passive containment cooling system
    Ge, Kui
    Zhang, Yapei
    Wang, Haoli
    Zhang, Chuanxu
    Tian, Wenxi
    Su, G.H.
    Qiu, Suizheng
    Yang, Changjiang
    Progress in Nuclear Energy, 2022, 153
  • [32] Experiment Research on Passive Containment Cooling System with Separated Heat Pipe
    Li J.
    Li X.
    Zhu C.
    Liu C.
    Han X.
    Jing C.
    Yuan Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2018, 52 (03): : 453 - 458
  • [33] Passive containment cooling system performance in the Simplified Boiling Water Reactor
    Shiralkar, BS
    Gamble, RE
    Yadigaroglu, G
    PROCEEDINGS OF THE INTERNATIONAL TOPICAL MEETING ON ADVANCED REACTORS SAFETY, VOLS 1 AND 2, 1997, : 478 - 484
  • [34] Development of a PCCS module in the ATHROC for simulation of passive containment cooling system
    Ge, Kui
    Zhang, Yapei
    Wang, Haoli
    Zhang, Chuanxu
    Tian, Wenxi
    Su, G. H.
    Qiu, Suizheng
    Yang, Changjiang
    PROGRESS IN NUCLEAR ENERGY, 2022, 153
  • [35] Research on heat and mass transfer model for passive containment cooling system
    Jiang, X.-W., 1600, Atomic Energy Press (34):
  • [37] Study on Passive Containment Cooling System Using Separated Heat Pipe
    Tao J.
    Cheng C.
    Xie X.
    Liang X.
    Chen J.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2018, 52 (08): : 1423 - 1430
  • [38] Study on the performance of an open-loop passive containment cooling system
    Bai, Jinhua
    Zhao, Bo
    Wang, Jianjun
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2018, 55 (01) : 113 - 121
  • [39] EVALUATION ON CAP1400 PASSIVE CONTAINMENT COOLING SYSTEM CAPABILITY
    Zhang Di
    Liu Xin
    Wang Zhe
    Wang Guodong
    Ni Chenxiao
    Wei Shengjie
    Hu Benxue
    Wang Zhangli
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 6, 2017,
  • [40] The statistical analysis of the passive system reliability in the Nuclear Power Plants (NPPs)
    Woo, Tae-Ho
    Lee, Un-Chul
    PROGRESS IN NUCLEAR ENERGY, 2010, 52 (05) : 456 - 461