Analysis of a passive containment cooling system for NPPs

被引:0
|
作者
Huang, Zheng [1 ]
机构
[1] China Nuclear Power Engineering Co. Ltd., Beijing,100840, China
来源
关键词
Tanks (containers) - Heat transfer;
D O I
10.13832/j.jnpe.2014.06.0031
中图分类号
学科分类号
摘要
By using RELAP5 and MELCOR, transient behaviors of containment and PCS were investigated. The Influences of various parameters, such as pressure, condenser area and loop height were also studied. The results show that the heat in the containment can be effectively removed by PCS in a period of accident without spray. However the tank water should be made up and cooled for the long run. The heat transfer power of two-phase flow case is always higher, and varies more substantially with pressure, than that of one-phase flow case under the same boundary temperatures. However, flow instability may occur for two-phase flow case. By increasing the condenser area, the heat transfer is enhanced. The influence is less insignificant when the tank temperature is relatively high. It is also found that for both one-phase and two-phase flow, the change of loop height has little effect upon the heat transfer power under the given boundary condition in this study. ©, 2014, Yuan Zi Neng Chuban She. All right reserved.
引用
收藏
页码:31 / 36
相关论文
共 50 条
  • [41] PASSIVE CONTAINMENT SYSTEM
    KLEIMOLA, FW
    RAUTIOLA, NA
    FALLS, OB
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1976, 24 (NOV19): : 357 - 359
  • [42] ANALYSIS OF 3-DIMENSIONAL HYDROGEN BEHAVIOR WITH PASSIVE CONTAINMENT COOLING
    Huang, Xingguan
    Fu, Tingzao
    Huang, Gaofeng
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 6, 2017,
  • [43] Conceptual design of passive containment cooling system with air holdup tanks in the concrete containment of improved APR
    Jeon, Byong Guk
    No, Hee Cheon
    NUCLEAR ENGINEERING AND DESIGN, 2014, 267 : 180 - 188
  • [44] Study on containment pressure response with passive containment cooling system performance under design basis accident
    Wang, Yan
    Yang, Yanning
    PROGRESS IN NUCLEAR ENERGY, 2017, 94 : 22 - 35
  • [45] Simulation of AP1000's passive containment cooling with the German Containment Code System COCOSYS
    Broxtermann, Philipp
    Allelein, Hans-Josef
    NUCLEAR ENGINEERING AND DESIGN, 2013, 261 : 326 - 332
  • [46] Influence of Passive Containment Cooling System on containment thermal hydraulic transients during a postulated severe accident
    Adinarayana, K. N., V
    Ali, Seik Mansoor
    PROGRESS IN NUCLEAR ENERGY, 2021, 142
  • [47] Analysis of AP1000 containment passive cooling system during a loss-of-coolant accident
    Hung, Zhen-Yu
    Ferng, Yuh-Ming
    Hsu, Wen-Sheng
    Pei, Bau-Shei
    Chen, Yen-Shu
    ANNALS OF NUCLEAR ENERGY, 2015, 85 : 717 - 724
  • [48] Experimental and Computational Analysis of a Passive Containment Cooling System with Closed-loop Heat Pipe Technology
    Lu Changdong
    Ji Wenying
    Yang Jiang
    Cai Wei
    Wang Ting
    Cheng Chehg
    Xiao Hon
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2020, 65 (05): : 280 - 286
  • [49] Analysis of Heat Transfer Performance Impact for Passive Containment Air-Cooling System Radiation Plates
    Wang, Hongliang
    Feng, Yu
    Yu, Mingrui
    Guo, Yong
    Li, Wei
    Guo, Qiang
    Yuan, Yidan
    ENERGIES, 2025, 18 (02)
  • [50] Experimental and computational analysis of a passive containment cooling system with closed-loop heat pipe technology
    Lu Changdong
    Ji Wenying
    Yang Jiang
    Cai Wei
    Wang Ting
    Cheng Cheng
    Xiao Hong
    PROGRESS IN NUCLEAR ENERGY, 2019, 113 : 206 - 214