Analysis of large scale tests for AP-600 passive containment cooling system

被引:0
|
作者
Sha, WT [1 ]
Chien, TH [1 ]
Sun, JG [1 ]
Chao, BT [1 ]
机构
[1] ANL E, Argonne, IL 60439 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
All next-generation light water reactors utilize passive systems to remove heat via natural circulation and are significantly different from past and current nuclear plant designs. One unique feature of the AP-600 is its passive containment cooling system (PCCS), which is designed to maintain containment pressure below the design limit for 72 hours without action by the reactor operator. During a design-basis accident, i.e., either a loss-of-coolant or a main steam-line break accident, steam escapes and comes in contact with the much cooler containment vessel wall. Heat is transfer ren to the inside surface of the steel containment wall by convection and condensation of steam and through the containment steel wall by conduction. Heat is then transferred from the outside of the containment surface by heating and evaporation of a thin liquid film that is formed by applying wafer at the top of the containment vessel dome. Air in the annular space is heated by both convection and injection of steam from the evaporating liquid film. The heated air and vapor rise as a result of natural circulation and exit the shield building through the outlets above the containment shell. All of the analytical models that are developed for and used in the COMMIX-ID code for predicting performance of rite PCCS will be described. These models cover governing conservation equations for multicomponents single phase flow: transport equations for the k-epsilon two-equation turbulence model, auxiliary equations, liquid-film tracking model for both inside (condensate) and outside (evaporating liquid film) surfaces of the containment vessel wall, thermal coupling between flow domains inside and outside the containment vessel, and heat and mass transfer models. Various key parameters of the COMMIX-ID results and corresponding AP-600 PCCS experimental data are compared and the agreement is good. Significant findings from this study are summarized.
引用
收藏
页码:199 / 216
页数:6
相关论文
共 50 条
  • [41] AP1000 Passive Containment Cooling System study under LBLOCA conditions using the GOTHIC code
    Estevez-Albuja, Samanta
    Fernandez-Cosials, Kevin
    Vazquez-Rodriguez, Carlos
    Goni-Velilla, Zurin
    Jimenez, Gonzalo
    NUCLEAR ENGINEERING AND DESIGN, 2021, 384
  • [42] INTEGRAL TESTING OF THE AP600 PASSIVE EMERGENCY CORE COOLING SYSTEMS
    HOCHREITER, LE
    FANTO, SV
    CONWAY, LE
    LAU, LK
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 1993, 207 (A4) : 259 - 268
  • [43] Thermal-hydraulic Analysis of Passive Containment Cooling System of HPR1000
    Qiu J.
    Wu J.
    Tian W.
    Wang Z.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2020, 54 (01): : 72 - 80
  • [44] Prediction of falling film evaporation on the AP1000 paSsive containment cooling system using ANSYS FLUENT code
    Wang, Xianmao
    Chang, Huajian
    Corradini, Michael
    Cong, Tenglong
    Wang, Jun
    ANNALS OF NUCLEAR ENERGY, 2016, 95 : 168 - 175
  • [45] Optimal design of passive containment cooling system for innovative PWR
    Ha, Huiun
    Lee, Sangwon
    Kim, Hangon
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (05) : 941 - 952
  • [46] Design of water distribution device for passive containment cooling system
    Zhang, Ting-Xiang
    Tang, Yu
    Hedongli Gongcheng/Nuclear Power Engineering, 2002, 23 (SUPPL.): : 103 - 106
  • [47] AEROSOL REMOVAL BY A HEAT EXCHANGER OF PASSIVE CONTAINMENT COOLING SYSTEM
    Liang, Yangyang
    Lu, Junjing
    Zhang, Tianqi
    Han, Xu
    Yuan, Yidan
    PROCEEDINGS OF 2021 28TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE28), VOL 2, 2021,
  • [48] Experimental study on transient characteristic of passive containment cooling system
    Cheng Cheng
    Wen Qing-long
    Wu Xiao-hang
    Li Yu
    Ju Peng
    INTERNATIONAL YOUTH NUCLEAR CONGRESS 2016, IYNC2016, 2017, 127 : 193 - 200
  • [49] A simplified model of Passive Containment Cooling System in a CFD code
    Jiang, X. W.
    Studer, E.
    Kudriakov, S.
    NUCLEAR ENGINEERING AND DESIGN, 2013, 262 : 579 - 588
  • [50] AN ADVANCED MODEL ON MIXED CONVECTION IN PASSIVE CONTAINMENT COOLING SYSTEM
    Zhang, He
    Niu, Fenglei
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 5, 2012, : 577 - 580