Inter-comparison of Dose Distributions Calculated by FLUKA, GEANT4, MCNP, and PHITS for Proton Therapy

被引:17
|
作者
Yang, Zi-Yi [1 ]
Tsai, Pi-En [1 ,2 ]
Lee, Shao-Chun [1 ]
Liu, Yen-Chiang [1 ]
Chen, Chin-Cheng [3 ]
Sato, Tatsuhiko [2 ]
Sheu, Rong-Jiun [1 ]
机构
[1] Natl Tsing Hua Univ, Inst Nucl Engn & Sci, Hsinchu, Taiwan
[2] Japan Atom Energy Agcy, Tokai, Ibaraki, Japan
[3] ProCure Proton Therapy Ctr, Somerset, NJ USA
关键词
BEAM THERAPY; PARTICLES; SETTINGS; MATTER; CODE;
D O I
10.1051/epjconf/201715304011
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The dose distributions from proton pencil beam scanning were calculated by FLUKA, GEANT4, MCNP, and PHITS, in order to investigate their applicability in proton radiotherapy. The first studied case was the integrated depth dose curves (IDDCs), respectively from a 100 and a 226-MeV proton pencil beam impinging a water phantom. The calculated IDDCs agree with each other as long as each code employs 75 eV for the ionization potential of water. The second case considered a similar condition of the first case but with proton energies in a Gaussian distribution. The comparison to the measurement indicates the inter-code differences might not only due to different stopping power but also the nuclear physics models. How the physics parameter setting affect the computation time was also discussed. In the third case, the applicability of each code for pencil beam scanning was confirmed by delivering a uniform volumetric dose distribution based on the treatment plan, and the results showed general agreement between each codes, the treatment plan, and the measurement, except that some deviations were found in the penumbra region. This study has demonstrated that the selected codes are all capable of performing dose calculations for therapeutic scanning proton beams with proper physics settings.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Distributions of positron-emitting nuclei in proton and carbon-ion therapy studied with GEANT4
    Pshenichnov, Igor
    Mishustin, Igor
    Greiner, Walter
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (23): : 6099 - 6112
  • [42] Implementation of a new Monte Carlo - GEANT4 simulation tool for the development of a proton therapy beam line and verification of the related dose distributions
    Cirrone, GAP
    Cuttone, G
    Guatelli, S
    Lo Nigro, S
    Mascialino, B
    Pia, MG
    Raffaele, L
    Russo, G
    Sabini, MG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 262 - 265
  • [43] Calculation of water equivalent ratios for various materials at proton energies ranging 10-500 MeV using MCNP, FLUKA, and GEANT4 Monte Carlo codes
    Safigholi, Habib
    Song, William Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15):
  • [44] Multi-threading performance of Geant4, MCNP6, and PHITS Monte Carlo codes for tetrahedral-mesh geometry
    Han, Min Cheol
    Yeom, Yeon Soo
    Lee, Hyun Su
    Shin, Bangho
    Kim, Chan Hyeong
    Furuta, Takuya
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (09):
  • [45] Performance Evaluation of Multithreaded Geant4 for Proton Therapy Dose Calculations in a High Performance Computing Facility
    Shin, J.
    Faddegon, B.
    Coss, D.
    McMurry, J.
    Farr, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 349 - 350
  • [46] Computation Speeds and Memory Requirements of Mesh-Type ICRP Reference Computational Phantoms in Geant4, MCNP6, and PHITS
    Yeom, Yeon Soo
    Han, Min Cheol
    Choi, Chansoo
    Han, Haegin
    Shin, Bangho
    Furuta, Takuya
    Kim, Chan Hyeong
    HEALTH PHYSICS, 2019, 116 (05): : 664 - 676
  • [47] Monte Carlo calculations of thermal neutron capture in gadolinium: A comparison of GEANT4 and MCNP with measurements
    Enger, SA
    Af Rosenschld, PM
    Rezaei, A
    Lundqvist, H
    MEDICAL PHYSICS, 2006, 33 (02) : 337 - 341
  • [48] Modeling Considerations for Improving Accuracy of a Proton Therapy Beam with GEANT4
    Barnes, Samuel R. S.
    McAuley, Grant A.
    Slater, James M.
    Wroe, Andrew J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2107 - 2112
  • [49] Comparison of the single and double count using MCNP6 and ONMS Geant4 software
    Dim, O. U.
    Aghara, S. K.
    Kutt, M.
    PROGRESS IN NUCLEAR ENERGY, 2020, 121
  • [50] Verification of the use of GEANT4 and MCNPX Monte Carlo codes for calculations of the depth-dose distributions in water for the proton therapy of eye tumours
    Grzadziel, Maigorzata
    Konefal, Adam
    Zipper, Wiktor
    Pietrzak, Robert
    Bzymek, Ewelina
    NUKLEONIKA, 2014, 59 (02) : 61 - 66