Validation of platelet counting accuracy with the Celltac F automated hematology analyzer

被引:3
|
作者
Nagai, Y
Kondo, H
Tatsumi, N
机构
[1] Nihon Kohden Corp, Tokyo 1618560, Japan
[2] Int Buddhist Univ, Osaka 5838501, Japan
关键词
D O I
10.1155/JAMMC.2005.235
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid and accurate analysis of platelet count plays an important role in evaluating hemorrhagic status. Therefore, we evaluated platelet counting performance of a hematology analyzer, Celltac F (MEK-8222, Nihon Kohden Corporation, Tokyo, Japan), that features easy use with low reagent consumption and high throughput while occupying minimal space in the clinical laboratory. All blood samples were anticoagulated with dipotassium ethylenediaminetetraacetic acid (EDTA-2K). The samples were stored at room temperature (18 degrees C-22 degrees C) and tested within 4 hours of phlebotomy. We evaluated the counting ability of the Celltac F hematology analyzer by comparing it with the platelet counts obtained by the flow cytometry method that ISLH and ICSH recommended, and also the manual visual method by Unopette (Becton Dickinson Vacutainer Systems). The ICSH/ISLH reference method is based on the fact that platelets can be stained with monoclonal antibodies to CD41 and/or CD61. The dilution ratio was optimized after the precision, coincidence events, and debris counts were confirmed by the reference method. Good correlation of platelet count between the Celltac F and the ICSH/ISLH reference method (r=0.99), and the manual visual method (r=0.93) were obtained. The regressions were y=0.90x+9.0 and y=1.11x+8.4, respectively. We conclude that the Celltac F hematology analyzer for platelet counting was well suited to the ICSH/ISLH reference method for rapidness and reliability.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 50 条
  • [41] The Automated Hematology Analyzer in the Small Cell Therapy Laboratory
    Caudill, B.
    Auker, M.
    Kelley, J. C.
    Winterstein, A.
    Bradbury, H.
    Daneault, B.
    Vasu, S.
    O'Donnell, L.
    TRANSFUSION, 2013, 53 : 68A - 68A
  • [42] Performance evaluation of leukocyte differential on the hematology analyzer Celltac G compared with two hematology analyzers, reference flow cytometry method, and two manual methods
    Yamade, Kenji
    Yamaguchi, Toshihiro
    Nagai, Yutaka
    Kamisako, Toshinori
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (08)
  • [43] Platelet counting using various hematology cell analyzers
    Dijkstra-Tiekstra, M. J.
    Kuipers, W.
    Setroikromo, A.
    de Wildt-Eggen, J.
    VOX SANGUINIS, 2006, 91 : 267 - 267
  • [44] An Assessment of the Reliability of Platelet-Associated Flags Generated By the Sysmex XE-5000 Automated Hematology Analyzer
    Hawkins, Jennifer
    Gulati, Gene
    Uppal, Guldeep
    Gong, Jerald
    MODERN PATHOLOGY, 2015, 28 : 500A - 500A
  • [45] An Assessment of the Reliability of Platelet-Associated Flags Generated By the Sysmex XE-5000 Automated Hematology Analyzer
    Hawkins, Jennifer
    Gulati, Gene
    Uppal, Guldeep
    Gong, Jerald
    LABORATORY INVESTIGATION, 2015, 95 : 500A - 500A
  • [46] More accurate and precise platelet count for analysis of thrombocytopenic samples by automated immunological method on a hematology analyzer.
    Gill, J
    Cowart, W
    Nepacena, J
    Doda, R
    Kim, YR
    Chupp, V
    BLOOD, 1997, 90 (10) : 3301 - 3301
  • [47] VALIDATION OF THE SYSMEX® XN-10 AUTOMATED HEMATOLOGY COUNTER FOR CELL COUNTING IN BONE MARROW SAMPLES
    Bastos, Rodrigo
    Penteado, Rosana
    Villarinho, Andrea
    Ito, Cristina
    Monteiro, Camila
    Sousa, Flavia
    Suganuma, Liliana
    Cardoso, Afonso
    Guerra, Joao
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 12 - 12
  • [48] Hemoglobin point-of-care testing in rural Gambia: Comparing accuracy of HemoCue and Aptus with an automated hematology analyzer
    Nass, Stefan A.
    Hossain, Ilias
    Sanyang, Chilel
    Baldeh, Bakary
    Pereira, Dora I. A.
    PLOS ONE, 2020, 15 (10):
  • [49] EVALUATION OF RETICULOCYTE COUNTING ON THE ROCHE COBAS M 511 HEMATOLOGY ANALYZER
    Harrison, Melody
    Zhang, Qian-Yun
    Bracco, Dan
    Allen, Tim
    Young, Steve
    George, Tracy
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 : 45 - 45
  • [50] AUTOMATED IMMATURE GRANULOCYTE COUNTS ON THE NEW SYSMEX XN AUTOMATED HEMATOLOGY ANALYZER
    Rosenthal, Nancy
    Connell, Barbara
    Brown, Bonnie
    Kruger, Julie
    Capper, Mary
    Blaine, Kimberly
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 130 - 130