Validation of platelet counting accuracy with the Celltac F automated hematology analyzer

被引:3
|
作者
Nagai, Y
Kondo, H
Tatsumi, N
机构
[1] Nihon Kohden Corp, Tokyo 1618560, Japan
[2] Int Buddhist Univ, Osaka 5838501, Japan
关键词
D O I
10.1155/JAMMC.2005.235
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid and accurate analysis of platelet count plays an important role in evaluating hemorrhagic status. Therefore, we evaluated platelet counting performance of a hematology analyzer, Celltac F (MEK-8222, Nihon Kohden Corporation, Tokyo, Japan), that features easy use with low reagent consumption and high throughput while occupying minimal space in the clinical laboratory. All blood samples were anticoagulated with dipotassium ethylenediaminetetraacetic acid (EDTA-2K). The samples were stored at room temperature (18 degrees C-22 degrees C) and tested within 4 hours of phlebotomy. We evaluated the counting ability of the Celltac F hematology analyzer by comparing it with the platelet counts obtained by the flow cytometry method that ISLH and ICSH recommended, and also the manual visual method by Unopette (Becton Dickinson Vacutainer Systems). The ICSH/ISLH reference method is based on the fact that platelets can be stained with monoclonal antibodies to CD41 and/or CD61. The dilution ratio was optimized after the precision, coincidence events, and debris counts were confirmed by the reference method. Good correlation of platelet count between the Celltac F and the ICSH/ISLH reference method (r=0.99), and the manual visual method (r=0.93) were obtained. The regressions were y=0.90x+9.0 and y=1.11x+8.4, respectively. We conclude that the Celltac F hematology analyzer for platelet counting was well suited to the ICSH/ISLH reference method for rapidness and reliability.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 50 条
  • [21] ACCURACY EVALUATION OF LOW PLATELET COUNTS ON THE COBAS M 511 INTEGRATED HEMATOLOGY ANALYZER
    van der Velden, Vincent H. J.
    Ropar, Kaitlin
    Bracco, Dan
    Allen, Tim
    Russcher, Henk
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 149 - 149
  • [22] The use of an automated hematology analyzer to determine the white cell count in platelet collections.
    Becker, JL
    Lorenzetti, L
    Safarian, D
    Myers, M
    BLOOD, 2001, 98 (11) : 539A - 539A
  • [23] Performance evaluation of platelet counting of Abbott Alinity hq and Sysmex XN-9000 automated hematology analyzer compared with international reference method
    Kim, Hyun-Young
    Bang, Sung-Hwan
    Cho, Duck
    Kim, Hee-Jin
    Kim, Sun-Hee
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (03) : 387 - 394
  • [24] Validation of a hematology analyzer in donkey medicine
    Ferreira, A. M.
    Meneses, G.
    Queiroga, F. L.
    Martins, A.
    Cruz, Z.
    Silvestre-Ferreira, A. C.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2024, 132
  • [25] AUTOMATED PLATELET COUNTING
    ROWAN, RM
    MCDONALD, GA
    NICOLL, WD
    BRITISH JOURNAL OF HAEMATOLOGY, 1977, 35 (04) : 666 - 667
  • [26] AUTOMATED PLATELET COUNTING
    GLASS, UH
    WETHERLE.G
    MILLS, RT
    PRIEST, CJ
    BRITISH JOURNAL OF HAEMATOLOGY, 1971, 21 (05) : 529 - &
  • [27] AUTOMATED PLATELET COUNTING
    HANDIN, RI
    LAWLER, KC
    VALERI, CR
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1971, 56 (05) : 661 - &
  • [28] Data collected from an automated hematology analyzer: Can this be used for analysis of apheresis platelet products?
    Myers, MM
    Becker, JL
    TRANSFUSION, 2001, 41 (09) : 50S - 50S
  • [29] Use of the Cell-Dyn Sapphire Hematology Analyzer for Automated Counting of Blood Cells in Body Fluids
    De Smet, Dieter
    Van Moer, Guy
    Martens, Geert A.
    Nanos, Nikolaos
    Smet, Lutgarde
    Jochmans, Kristin
    De Waele, Marc
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2010, 133 (02) : 291 - 299
  • [30] Evaluation of performance parameters of an automated hematology analyzer
    Pares, Jesica
    Borda, Natalia
    Damian Santiago, Sergio
    Benito, Cristina
    Aranda, Claudio
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2015, 49 (04): : 399 - 407