Validation of platelet counting accuracy with the Celltac F automated hematology analyzer

被引:3
|
作者
Nagai, Y
Kondo, H
Tatsumi, N
机构
[1] Nihon Kohden Corp, Tokyo 1618560, Japan
[2] Int Buddhist Univ, Osaka 5838501, Japan
关键词
D O I
10.1155/JAMMC.2005.235
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid and accurate analysis of platelet count plays an important role in evaluating hemorrhagic status. Therefore, we evaluated platelet counting performance of a hematology analyzer, Celltac F (MEK-8222, Nihon Kohden Corporation, Tokyo, Japan), that features easy use with low reagent consumption and high throughput while occupying minimal space in the clinical laboratory. All blood samples were anticoagulated with dipotassium ethylenediaminetetraacetic acid (EDTA-2K). The samples were stored at room temperature (18 degrees C-22 degrees C) and tested within 4 hours of phlebotomy. We evaluated the counting ability of the Celltac F hematology analyzer by comparing it with the platelet counts obtained by the flow cytometry method that ISLH and ICSH recommended, and also the manual visual method by Unopette (Becton Dickinson Vacutainer Systems). The ICSH/ISLH reference method is based on the fact that platelets can be stained with monoclonal antibodies to CD41 and/or CD61. The dilution ratio was optimized after the precision, coincidence events, and debris counts were confirmed by the reference method. Good correlation of platelet count between the Celltac F and the ICSH/ISLH reference method (r=0.99), and the manual visual method (r=0.93) were obtained. The regressions were y=0.90x+9.0 and y=1.11x+8.4, respectively. We conclude that the Celltac F hematology analyzer for platelet counting was well suited to the ICSH/ISLH reference method for rapidness and reliability.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 50 条
  • [1] Validation of the Celltac alpha automated hematology analyzer for canine and feline blood samples
    McDaniel, Barbara Jane
    Hirschberger, Johannes
    Weber, Karin
    VETERINARY CLINICAL PATHOLOGY, 2013, 42 (01) : 11 - 18
  • [2] Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer
    Fukuda, Teruko
    Asou, Eri
    Nogi, Kimiko
    Goto, Kazuo
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2017, 79 (10): : 1707 - 1711
  • [3] Producing accurate platelet counts for platelet rich plasma: Validation of a hematology analyzer and preparation techniques for counting
    Woodell-May, JE
    Ridderman, DN
    Swift, MJ
    Higgins, J
    JOURNAL OF CRANIOFACIAL SURGERY, 2005, 16 (05) : 749 - 756
  • [4] Automated Hematology Analyzer for Cell Counting in Body Fluid
    Joob, Beuy
    Wiwanitkit, Viroj
    CLINICAL LABORATORY, 2017, 63 (5-6) : 1041 - 1041
  • [5] PLATELET COUNTING, STILL DIFFICULT IN AUTOMATED HEMATOLOGY
    VANDERWOERDDELANGE, JA
    STEURER, R
    HUSKEN, M
    WEISS, L
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1985, 23 (09): : 575 - 575
  • [6] Performance evaluation of optical platelet counting of BC-6000Plus automated hematology analyzer
    Hu, Xuehua
    Tang, Yuqun
    Li, Mingyi
    Fu, Chunyun
    Deng, Zuoxin
    Tang, Wenting
    Zhou, Huideng
    Chen, Yan
    Li, Yingfeng
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (06)
  • [7] Producing accurate platelet counts for platelet rich plasma: Validation of a hematology analyzer and preparation techniques for counting - Discussion
    Wan, DC
    Longaker, MT
    JOURNAL OF CRANIOFACIAL SURGERY, 2005, 16 (05) : 757 - 759
  • [8] Platelet counting in platelet concentrates with various automated hematology analyzers
    Dijkstra-Tiekstra, Margriet J.
    Kuipers, Willeke
    Setroikromo, Airies C.
    de Wildt-Eggen, Janny
    TRANSFUSION, 2007, 47 (09) : 1651 - 1657
  • [9] Platelet count evaluation compared with the immunoplatelet reference method and performance evaluation of the hematology analyzer Celltac G
    Yamade, Kenji
    Yamaguchi, Toshihiro
    Nagai, Yutaka
    Kamisako, Toshinori
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (05) : 927 - 938
  • [10] Accuracy study of a novel alternate method measuring erythrocyte sedimentation rate for prototype hematology analyzer Celltac α
    Maki, Ryosuke
    Tabe, Yoko
    Yamamoto, Takamasa
    Takemura, Hiroyuki
    Sawada, Tomohiro
    Esaki, Tatsuhiro
    Higuchi, Makoto
    Misawa, Shigeki
    Miyake, Kazunori
    Miida, Takashi
    Nagai, Yutaka
    Ohsaka, Akimichi
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (04) : 588 - 596