Simultaneous assessment of endothelial function and morphology in the brachial artery using a new semiautomatic ultrasound system

被引:11
|
作者
Iguchi, Tomokazu [1 ]
Takemoto, Yasuhiko [1 ,2 ]
Shimada, Kenei [1 ]
Matsumoto, Kenji [1 ]
Nakanishi, Koki [1 ]
Otsuka, Kenichiro [1 ]
Hyodo, Eiichi [1 ]
Hirohashi, Kazuhiro [1 ,2 ]
Tahara, Akira [1 ,3 ]
Yoshiyama, Minoru [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Internal Med & Cardiol, Osaka 5458585, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Grad Med Educ & Gen Practice, Osaka 5458585, Japan
[3] Asakayama Gen Hosp, Dept Internal Med & Cardiol, Osaka, Japan
关键词
brachial artery; flow-mediated dilatation; intima-media thickness; simultaneous automated measurements; INTIMA-MEDIA THICKNESS; WALL THICKNESS; CAROTID-ARTERY; RISK-FACTORS; CARDIOVASCULAR EVENTS; PREDICTIVE-VALUE; ATHEROSCLEROSIS; DILATION; DISEASE; VASODILATION;
D O I
10.1038/hr.2013.35
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The accuracy of measurements of the intima-media thickness (IMT) and flow-mediated dilatation (FMD) of the brachial artery made using a new semiautomated ultrasound system and the relationships among those parameters and the Framingham Risk Score (FRS) as a predictor of coronary heart disease (CHD) are unknown. We enrolled 70 subjects, including 47 patients with cardiovascular risk factors and 23 normal healthy volunteers. IMT and FMD were simultaneously measured using a new semiautomated ultrasound system, and the measurements were compared with those obtained manually as a reference standard (study 1). In addition, we enrolled 200 consecutive patients with risk factors but no CHD to examine the relationships among IMT, FMD and the FRS. The optimal cutoff values of FMD and IMT were determined in 200 patients without CHD, and the subjects were classified into four groups. The 10-year Framingham risks for each group were compared (study 2). FMD and IMT measurements made using the new semiautomated ultrasound system showed a good correlation with the measurements determined manually (study 1). Furthermore, FMD and IMT showed a significant correlation with the FRS. The 10-year Framingham risk was markedly higher in group D (FMD <5.5% and IMT >0.3 mm; 19.0 +/- 11.3%; study 2). In conclusion, the measurements made using a new semiautomated ultrasound system provided reliable and simultaneous evaluations of IMT and FMD. The combination of IMT and FMD measurements of the brachial artery may be beneficial for risk stratification of patients with cardiovascular risk factors but no CHD.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [21] Baseline brachial artery diameter is a predictor of endothelial function assessed by brachial artery vasoreactivity testing
    Shechter, M
    Freimark, D
    Usmanov, V
    Feinberg, MS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 451A - 451A
  • [22] Ultrasound assessment of brachial endothelial vasomotor function in addition to carotid plaque echolucency for predicting cardiovascular events in patients with coronary artery disease
    Nakamura, Takamitsu
    Kitta, Yoshinobu
    Uematsu, Manabu
    Sugamata, Wataru
    Hirano, Mitsumasa
    Fujioka, Daisuke
    Sano, Keita
    Saito, Yukio
    Kawabata, Ken-ichi
    Obata, Jun-ei
    Kugiyama, Kiyotaka
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (02) : 555 - 560
  • [23] ASSESSMENT OF SYSTEMIC ENDOTHELIAL FUNCTION IN PATIENTS WITH CIRRHOSIS: COMPARISON BETWEEN PERIPHERAL ARTERIAL TONOMETRY (PAT) AND BRACHIAL ARTERY VASODILATATION BY ULTRASOUND (BAUS)
    Berzigotti, A.
    Seijo, S.
    Reverter, E.
    Abraldes, J. G.
    Garcia-Pagan, J. C.
    Bosch, J.
    JOURNAL OF HEPATOLOGY, 2011, 54 : S240 - S240
  • [24] Does Brachial Artery Endothelial Function Represent The Endothelial Function During Prolonged Sitting?
    Wallace, Janet P.
    Bielko, Sylvanna L.
    Wiggins, Chad H.
    Mather, Kieren J.
    Thosar, Saurabh S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 13 - 13
  • [25] Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery - A report of the International Brachial Artery Reactivity Task Force
    Corretti, MC
    Anderson, TJ
    Benjamin, EJ
    Celermajer, D
    Charbonneau, F
    Creager, MA
    Deanfield, J
    Drexler, H
    Gerhard-Herman, M
    Herrington, D
    Vallance, P
    Vita, J
    Vogel, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (02) : 257 - 265
  • [26] Assessment of endothelial function in postpartum pre-eclamptic women using flow-mediated dilation of the brachial artery
    Tripathy, P.
    Sahu, A.
    Nagy, A.
    Mohanty, J.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2019, 126 : 172 - 172
  • [27] Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
    Alley, Hugh
    Owens, Christopher D.
    Gasper, Warren J.
    Grenon, S. Marlene
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (92):
  • [28] Comprehensive assessment of impaired peripheral and coronary artery endothelial functions in smokers using brachial artery ultrasound and oxygen-15-labeled water PET
    Ochi, Noriki
    Yoshinaga, Keiichiro
    Ito, Yoichi M.
    Tomiyama, Yuuki
    Inoue, Mamiko
    Nishida, Mutsumi
    Manabe, Osamu
    Shibuya, Hitoshi
    Shimizu, Chikara
    Suzuki, Eriko
    Fujii, Satoshi
    Katoh, Chietsugu
    Tamaki, Nagara
    JOURNAL OF CARDIOLOGY, 2016, 68 (3-4) : 316 - 323
  • [29] Intima-media Thickness of Brachial Artery and Endothelial Function
    Maruhashi, Tatsuya
    Higashi, Yukihito
    Iwamoto, Yumiko
    Fujii, Yuichi
    Idei, Naomi
    Fujimura, Noritaka
    Mikami, Shinsuke
    Kajikawa, Masato
    Matsumoto, Takeshi
    Nakashima, Ayumu
    Noma, Kensuke
    Kihara, Yasuki
    CIRCULATION, 2012, 126 (21)
  • [30] Effects of Hemodialysis on Brachial Artery Endothelial Function A Clinical Study
    Li, Xiang
    Li, Lina
    Fang, Shibao
    Xu, Yan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (11) : 1783 - 1787