Simultaneous assessment of endothelial function and morphology in the brachial artery using a new semiautomatic ultrasound system

被引:11
|
作者
Iguchi, Tomokazu [1 ]
Takemoto, Yasuhiko [1 ,2 ]
Shimada, Kenei [1 ]
Matsumoto, Kenji [1 ]
Nakanishi, Koki [1 ]
Otsuka, Kenichiro [1 ]
Hyodo, Eiichi [1 ]
Hirohashi, Kazuhiro [1 ,2 ]
Tahara, Akira [1 ,3 ]
Yoshiyama, Minoru [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Internal Med & Cardiol, Osaka 5458585, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Grad Med Educ & Gen Practice, Osaka 5458585, Japan
[3] Asakayama Gen Hosp, Dept Internal Med & Cardiol, Osaka, Japan
关键词
brachial artery; flow-mediated dilatation; intima-media thickness; simultaneous automated measurements; INTIMA-MEDIA THICKNESS; WALL THICKNESS; CAROTID-ARTERY; RISK-FACTORS; CARDIOVASCULAR EVENTS; PREDICTIVE-VALUE; ATHEROSCLEROSIS; DILATION; DISEASE; VASODILATION;
D O I
10.1038/hr.2013.35
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The accuracy of measurements of the intima-media thickness (IMT) and flow-mediated dilatation (FMD) of the brachial artery made using a new semiautomated ultrasound system and the relationships among those parameters and the Framingham Risk Score (FRS) as a predictor of coronary heart disease (CHD) are unknown. We enrolled 70 subjects, including 47 patients with cardiovascular risk factors and 23 normal healthy volunteers. IMT and FMD were simultaneously measured using a new semiautomated ultrasound system, and the measurements were compared with those obtained manually as a reference standard (study 1). In addition, we enrolled 200 consecutive patients with risk factors but no CHD to examine the relationships among IMT, FMD and the FRS. The optimal cutoff values of FMD and IMT were determined in 200 patients without CHD, and the subjects were classified into four groups. The 10-year Framingham risks for each group were compared (study 2). FMD and IMT measurements made using the new semiautomated ultrasound system showed a good correlation with the measurements determined manually (study 1). Furthermore, FMD and IMT showed a significant correlation with the FRS. The 10-year Framingham risk was markedly higher in group D (FMD <5.5% and IMT >0.3 mm; 19.0 +/- 11.3%; study 2). In conclusion, the measurements made using a new semiautomated ultrasound system provided reliable and simultaneous evaluations of IMT and FMD. The combination of IMT and FMD measurements of the brachial artery may be beneficial for risk stratification of patients with cardiovascular risk factors but no CHD.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [11] Cyclic changes in brachial artery diameter: Implications for clinical measurements and assessment of endothelial function by hand-carried ultrasound
    Chuang, ML
    Douglas, PS
    Stein, JH
    RADIOLOGY, 2001, 221 : 593 - 593
  • [12] Assessment of endothelial function by brachial artery flow mediated dilatation in microvascular disease
    Otikunta Adikesava Naidu
    Durgaprasad Rajasekhar
    SAA Latheef
    Cardiovascular Ultrasound, 9
  • [13] Assessment of endothelial function by brachial artery flow mediated dilatation in microvascular disease
    Naidu, Otikunta Adikesava
    Rajasekhar, Durgaprasad
    Latheef, S. A. A.
    CARDIOVASCULAR ULTRASOUND, 2011, 9
  • [14] Detection of endothelial dysfunction with brachial artery ultrasound scanning
    Faulx, MD
    Wright, AT
    Hoit, BD
    AMERICAN HEART JOURNAL, 2003, 145 (06) : 943 - 951
  • [15] Evaluation of endothelial function in patients with limited systemic sclerosis by use of brachial artery Doppler ultrasound
    Fernandes, Tatiana Melo
    Gomes Bica, Blanca Elena
    Villela, Nivaldo Ribeiro
    Salles, Elizabeth Figueiredo
    Leitao de Azevedo, Mario Newton
    de Souza Papi, Jose Angelo
    Gomes Martins, Rosangela Aparecida
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2012, 52 (04) : 554 - 568
  • [16] Assessment of endothelial function by ultrasound as a screening test for coronary artery disease
    Schröder, S
    Enderle, MD
    Meisner, C
    Baumbach, A
    Herdeg, C
    Oberhoff, M
    Ossen, R
    Pfohl, M
    Karsch, KR
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1999, 124 (30) : 886 - 890
  • [17] Comparison of the evaluation of endothelial function by flow mediated dilatation using brachial artery or popliteal artery
    Rosano, GMC
    Pelliccia, F
    Cerquetani, E
    Leonardo, F
    Pagnotta, P
    Chierchia, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 327A - 328A
  • [18] Measurement of brachial artery endothelial function using a standard blood pressure cuff
    Maltz, Jonathan S.
    Tison, Geoffrey H.
    Alley, Hugh F.
    Budinger, Thomas F.
    Owens, Christopher D.
    Olgin, Jeffrey
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (11) : 2247 - 2268
  • [19] Endothelial vasodilatation reserve assessment for brachial artery using paired test with hyperemia
    Polonetsky, L.
    Gul, L.
    Shantsila, E.
    Lakhanko, L.
    Yasinskaya, S.
    Polonetsky, I.
    EUROPEAN HEART JOURNAL, 2007, 28 : 47 - 47
  • [20] Assessment of endothelial function by ultrasound
    Ranke, C
    Trappe, HJ
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1999, 124 (30) : 885 - 885