Experimental investigation of an ejector-enhanced auto-cascade refrigeration system

被引:56
|
作者
Bai, Tao [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Experimental investigation; Ejector; Zeotropic refrigerant; Auto-cascade refrigeration; Exergy efficiency; CO2; HEAT-PUMP; EXERGY ANALYSIS; PERFORMANCE; CYCLE; MIXTURE; ENERGY;
D O I
10.1016/j.applthermaleng.2017.10.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents the experimental investigation of an ejector-enhanced auto-cascade refrigeration cycle (EARC) with zeotropic refrigerant R134a/R23. Performance comparisons among the EARC and two conventional cycles were conducted at selected operating conditions. The effects of ambient temperature, charged mass fraction ratio of the mixture, throttle valve opening, and heat load on the performance characteristics of the EARC were investigated. The results indicated that the EARC had more advantages in terms of lower refrigeration temperature and higher energy utilization efficiency over the conventional cycles, and the coefficient of performance (COP) and exergy efficiency improvements of the EARC reached up to 9.6% and 25.1%, respectively. The throttle valve opening was optimal with respect to the maximum system exergy efficiency determination. The refrigerant R134a/R23 with the optimal mass fraction ratio of 0.70/0.30 was proposed. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:792 / 801
页数:10
相关论文
共 50 条
  • [31] Study on an Auto-cascade Parallel-compression Refrigeration Cycle
    Yuan, Jiajia
    Wang, Lin
    Tan, Yingying
    Li, Xiuzhen
    Wang, Zhanwei
    Huang, Lisheng
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (11): : 2886 - 2892
  • [32] Equivalent Cycle and Optimization of Auto-Cascade Absorption Refrigeration Systems
    He, Yijian
    Chen, Guangming
    JOURNAL OF THERMAL SCIENCE, 2020, 29 (04) : 1053 - 1062
  • [33] Experimental study on a four-stage auto-cascade refrigeration system with the temperature down to-150 °C
    Xiao, C. J.
    Zhang, H.
    Liu, H. S.
    Liu, Z. J.
    Zhang, J. T.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 541 - 544
  • [34] Equivalent Cycle and Optimization of Auto-Cascade Absorption Refrigeration Systems
    HE Yijian
    CHEN Guangming
    Journal of Thermal Science, 2020, 29 (04) : 1053 - 1062
  • [35] Advanced exergy analysis on a modified auto-cascade freezer cycle with an ejector
    Bai, Tao
    Yu, Jianlin
    Yan, Gang
    ENERGY, 2016, 113 : 385 - 398
  • [36] A potential auto-cascade absorption refrigeration system for pre-cooling of LNG liquefaction
    He, Yijian
    Li, Rong
    Chen, Guangming
    Wang, Yi
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2015, 24 : 425 - 430
  • [37] Thermodynamic Analysis of an Innovative Cold Energy Storage System for Auto-Cascade Refrigeration Applications
    Liu, Zhenzhen
    Jiang, Jingde
    Wang, Zilong
    Zhang, Hua
    ENERGIES, 2023, 16 (05)
  • [38] A novel online measurement method for compositions and energy performance of an auto-cascade refrigeration system
    Li, Yinlong
    Yan, Gang
    Jing, Dongliang
    Liu, Guoqiang
    Llopis, Rodrigo
    ENERGY, 2025, 318
  • [39] Experimental investigation of the performance of a single-stage auto-cascade refrigerator
    Rui, Shengjun
    Zhang, Hua
    Zhang, Bohan
    Wen, Dongsheng
    HEAT AND MASS TRANSFER, 2016, 52 (01) : 11 - 20
  • [40] Exergy analysis and preliminary experimental investigation on a mixture auto-cascade refrigerator
    Gong, M.Q.
    Zhou, Y.
    Luo, E.C.
    Wu, J.F.
    Qi, Y.F.
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2001, 22 (06):