Experimental investigation of an ejector-enhanced auto-cascade refrigeration system

被引:56
|
作者
Bai, Tao [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Experimental investigation; Ejector; Zeotropic refrigerant; Auto-cascade refrigeration; Exergy efficiency; CO2; HEAT-PUMP; EXERGY ANALYSIS; PERFORMANCE; CYCLE; MIXTURE; ENERGY;
D O I
10.1016/j.applthermaleng.2017.10.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents the experimental investigation of an ejector-enhanced auto-cascade refrigeration cycle (EARC) with zeotropic refrigerant R134a/R23. Performance comparisons among the EARC and two conventional cycles were conducted at selected operating conditions. The effects of ambient temperature, charged mass fraction ratio of the mixture, throttle valve opening, and heat load on the performance characteristics of the EARC were investigated. The results indicated that the EARC had more advantages in terms of lower refrigeration temperature and higher energy utilization efficiency over the conventional cycles, and the coefficient of performance (COP) and exergy efficiency improvements of the EARC reached up to 9.6% and 25.1%, respectively. The throttle valve opening was optimal with respect to the maximum system exergy efficiency determination. The refrigerant R134a/R23 with the optimal mass fraction ratio of 0.70/0.30 was proposed. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:792 / 801
页数:10
相关论文
共 50 条
  • [21] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    BAI Tao
    LU Yu
    YAN Gang
    YU Jianlin
    JournalofThermalScience, 2021, 30 (06) : 2015 - 2026
  • [22] Theoretical study on a new auto-cascade absorption refrigeration system
    Zhong, Yongfang
    Chen, Guangming
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2002, 23 (06): : 786 - 790
  • [23] Study on mix flow characteristics in auto-cascade refrigeration system
    Liu, H. S.
    Zhang, H.
    Liu, Z. J.
    Jing, L.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 545 - 550
  • [24] Performance analysis of a dual-ejector enhanced two-stage auto-cascade refrigeration cycle for ultra-low temperature refrigeration
    Shi, Rongxuan
    Bai, Tao
    Wan, Jiahao
    APPLIED THERMAL ENGINEERING, 2024, 240
  • [25] Characteristics of two-stage segregation auto-cascade refrigeration system
    Rui, Shengjun
    Zhang, Hua
    Zhang, Qinggang
    Huang, Lihao
    Huagong Xuebao/CIESC Journal, 2013, 64 (06): : 2029 - 2035
  • [26] The research on the performance comparison of the auto-cascade refrigeration systems
    Hu, Chunxia
    Shi, Yang
    Zhao, Xiangge
    Liu, Guanjun
    Energy Education Science and Technology Part A: Energy Science and Research, 2012, 30 (SUPPL.2): : 69 - 76
  • [27] Performance Analysis of Auto-cascade Refrigeration System Based on T-junction
    Su, Dandan
    Xu, Yuanxin
    Xu, Weicong
    Zhao, Li
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (03): : 652 - 660
  • [28] The Study of the Effects of Refrigerant Fraction on Auto-cascade Refrigeration System of Evaporation Temperature
    Zheng Da-yu
    Li Dan
    Zheng Jia
    Gao Li-ping
    Zhang Yi-ming
    ENGINEERING SOLUTIONS FOR MANUFACTURING PROCESSES IV, PTS 1 AND 2, 2014, 889-890 : 321 - 324
  • [29] Experimental investigation on the performance of a-120 °C ultralow temperature refrigeration system based on a three-stage auto-cascade cycle
    Qin, Yanbin
    Zhang, Shaojie
    Zhang, Hua
    Tan, Yuxuan
    Zhou, Guozhong
    Liu, Baolin
    ENERGY, 2025, 320
  • [30] Theoretical simulation and experimental study on effect of mixture ratio in auto-cascade refrigeration cycle
    He S.
    Shao C.
    Yang Y.
    Wang C.
    Zhao Y.
    Huagong Xuebao/CIESC Journal, 2018, 69 : 108 - 114