Ability of Fourier-domain Optical Coherence Tomography to Detect Retinal Ganglion Cell Complex Atrophy in Glaucoma Patients

被引:20
|
作者
Sevim, Mehmet Sahin [1 ]
Buttanri, Bulent [1 ]
Acar, Banu Torun [1 ]
Kahya, Alev [1 ]
Vural, Ece Turan [1 ]
Acar, Suphi [1 ]
机构
[1] Haydarpasa Numune Res & Educ Hosp, Dept Ophthalmol, Istanbul, Turkey
关键词
Fourier-domain optical coherence tomography; retinal ganglion cell complex; glaucoma; NERVE-FIBER LAYER; THICKNESS MEASUREMENTS; HUMAN EYES; DAMAGE; REPRODUCIBILITY; DIAGNOSIS; DEFECTS; OCT;
D O I
10.1097/IJG.0b013e31824d1f97
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Purpose: To evaluate the diagnostic ability of Fourier-domain optical coherence tomography (FD-OCT) measurements in both normal individuals and patients with different stages of glaucoma. Patients and Methods: Patients and Methods: A total of 113 patients diagnosed with glaucoma and classified into different stages of glaucoma according to Glaucoma Staging System 2 and 30 healthy individuals were included in this study. In all patients, parameters of both the retinal ganglion cell complex (GCC) and the peripapillary retinal nerve fiber layer were measured by FD-OCT (RTVue-100). Comparisons were made from measurements in patients with different stages of glaucoma. Results: Results: Both GCC and retinal nerve fiber layer thickness values of patients with glaucoma were statistically significantly lower compared with those of healthy individuals. As the stage of glaucoma progressed, the mean GCC and retinal nerve fiber layer thickness values decreased. Conclusions: Conclusions: GCC and retinal nerve fiber layer thickness measurements performed by FD-OCT showed high diagnostic ability in detecting glaucoma. Mean thickness values can be determined for each glaucoma stage.
引用
收藏
页码:542 / 549
页数:8
相关论文
共 50 条
  • [41] Corneal power measurement with Fourier-domain optical coherence tomography
    Tang, Maolong
    Chen, Alex
    Li, Yan
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2115 - 2122
  • [42] Reproducibility of intracoronary Fourier-domain optical coherence tomography analysis
    Orii, M.
    Kubo, T.
    Kitabata, H.
    Ishibashi, K.
    Yamano, T.
    Tanimoto, T.
    Ino, Y.
    Yamaguchi, T.
    Imanishi, T.
    Akasaka, T.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1000 - 1000
  • [43] Fourier-domain optical coherence tomography: next step in optical imaging
    Wojtkowski, M
    Kowalczyk, A
    Targowski, P
    Gorczynska, I
    OPTICA APPLICATA, 2002, 32 (04) : 569 - 580
  • [44] Retinal morphological changes of patients with X-linked retinoschisis evaluated by Fourier-domain optical coherence tomography
    Gerth, Christina
    Zawadzki, Robert J.
    Werner, John S.
    Heon, Elise
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (06) : 807 - 811
  • [45] Time-gated Fourier-domain optical coherence tomography
    Muller, Matthew S.
    Webster, Paul J. L.
    Fraser, James M.
    OPTICS LETTERS, 2007, 32 (22) : 3336 - 3338
  • [46] In vitro validation of new Fourier-domain optical coherence tomography
    Tahara, Satoko
    Bezerra, Hiram G.
    Baibars, Motaz
    Kyono, Hiroyuki
    Wang, Wei
    Pokras, Stan
    Mehanna, Emile
    Petersen, Christopher L.
    Costa, Marco A.
    EUROINTERVENTION, 2011, 6 (07) : 875 - 882
  • [47] Full-field Fourier-domain optical coherence tomography
    Zvyagin, AV
    Blazkiewicz, P
    Vintrou, J
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 44 - 53
  • [48] Line-field Fourier-domain optical coherence tomography
    Endo, T
    Yasuno, Y
    Truffer, F
    Aoki, G
    Makita, S
    Itoh, M
    Yatagai, T
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 168 - 173
  • [49] Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography in the Detection of Band Atrophy of the Optic Nerve
    Costa-Cunha, Luciana V. F.
    Cunha, Leonardo P.
    Malta, Roberto F. S.
    Monteiro, Mario L. R.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (01) : 56 - 63
  • [50] Compensation of Backscattering Coefficient in Fourier-Domain Optical Coherence Tomography
    Lin Ling
    Zhang Tae-Sok
    Ren Zhao
    Li Gang
    Zeng Rui-li
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (10) : 2243 - 2248