Response to Wollin re: "Strike Rate: Analysis of Laser Fiber to Stone Distance During Different Modes of Laser Lithotripsy"

被引:0
|
作者
Aldoukhi, Ali H. [1 ]
Hall, Timothy L. [2 ]
Ghani, Khurshid R. [1 ]
Roberts, William W. [1 ,2 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Urol, Ann Arbor, MI 48109 USA
关键词
HOLMIUM;
D O I
10.1089/end.2021.29105.aha
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Different techniques of laser lithotripsy (fragmentation, dusting, and popcorning) are commonly used during ureteroscopy. The efficiency of a single laser pulse is dependent on minimizing laser fiber-stone distance, yet it has not been reported how often the laser fiber is in contact with the stone during laser lithotripsy. In this study, we sought to measure laser fiber to stone distance using light reflectance for each technique of laser lithotripsy. Methods: Continuous light from a 660 nm (red) light-emitting diode (LED) was coupled into a 200 μm fiber using a fiber X-coupler. The LED fiber was positioned immediately next to a 242 μm holmium fiber, and both were passed through the working channel of an ureteroscope. One fiber was used to deliver laser energy to the stone, and the other fiber was used to measure distance based on light reflected from the stone back into the fiber. For fragmentation and dusting experiments, a 5 mm BegoStone was placed into a 20 mm three-dimensional printed caliceal model. For popcorn experiments, 10 BegoStones (3 × 3 × 1.5 mm) were placed in an 11 mm caliceal model and the laser fiber positioned 2 mm away from the stone surface. Data were analyzed using a MATLAB software to report fiber to stone distance at each laser pulse. Results: With fragmentation, 52% of laser pulses were delivered when the fiber was within 0.5 mm of the stone compared to 23% and 4% for dusting and popcorning, respectively. Laser pulses delivered when fiber to stone distance was >1 mm (least effective) accounted for 34%, 48%, and >80% of total pulses during fragmentation, dusting, and popcorning, respectively. Conclusion: Current methods of laser lithotripsy that rely on fixed firing rates are inefficient, especially for the popcorn technique. These data highlight areas for improvement by appropriately gating pulse delivery to maximize lithotripsy effect for each pulse fired. © Copyright 2021, Mary Ann Liebert, Inc., publishers 2021.
引用
收藏
页码:361 / 361
页数:1
相关论文
共 34 条
  • [21] Determination of urinary stone composition using biochemical analysis of fluid samples taken during ureterorenoscopic laser lithotripsy
    I. Ethem Arslan
    Hakan Kilicarslan
    M. Cagatay Cicek
    K. Omur Gunseren
    Gokhan Ocakoglu
    Onur Kaygısız
    International Urology and Nephrology, 2019, 51 : 1941 - 1947
  • [22] Determination of urinary stone composition using biochemical analysis of fluid samples taken during ureterorenoscopic laser lithotripsy
    Arslan, I. Ethem
    Kilicarslan, Hakan
    Cicek, M. Cagatay
    Gunseren, K. Omur
    Ocakoglu, Gokhan
    Kaygisiz, Onur
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2019, 51 (11) : 1941 - 1947
  • [23] Kidney Stone Ablation Times and Peak Saline Temperatures During Holmium: YAG and Thulium Fiber Laser Lithotripsy, In Vitro, in a Ureteral Model
    Hardy, Luke A.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XI, 2015, 9303
  • [24] How much energy do we need to ablate 1 cubic millimeter of stone during Thulium Fiber Laser lithotripsy? An in vitro study
    Panthier, Frederic
    Chicaud, Marie
    Doizi, Steeve
    Kutchukian, Stessy
    Lapouge, Pierre
    Solano, Catalina
    Candela, Luigi
    Daudon, Michel
    Berthe, Laurent
    Corrales, Mariela
    Traxer, Olivier
    WORLD JOURNAL OF UROLOGY, 2024, 42 (01)
  • [25] Adverse events related to laser fibers and laser machines during ureteroscopy and stone lithotripsy: Insights from an updated 10-year analysis of the US MAUDE database
    Juliebo-Jones, Patrick
    Aesoy, Mathias Sorstrand
    Beisland, Christian
    De Coninck, Vincent
    Keller, Etienne Xavier
    Tzelves, Lazaros
    Gjengsto, Peder
    Moen, Christian Arvei
    Somani, Bhaskar K.
    Ulvik, Oyvind
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2024, 96 (03)
  • [26] Re.: Temperature rise during ureteral laser lithotripsy: comparison of superpulse thulium fiber laser (SPTF) vs. high-power 120 W holmium–YAG laser (Ho:YAG)
    Mark Taratkin
    Thomas R. W. Herrmann
    Dmitry Enikeev
    World Journal of Urology, 2022, 40 : 1259 - 1260
  • [27] Re.: Temperature rise during ureteral laser lithotripsy: comparison of superpulse thulium fiber laser (SPTF) vs. high-power 120 W holmium-YAG laser (Ho:YAG)
    Taratkin, Mark
    Herrmann, Thomas R. W.
    Enikeev, Dmitry
    WORLD JOURNAL OF UROLOGY, 2022, 40 (05) : 1259 - 1260
  • [28] Re: Mahajan AD, Mahajan SA. Thulium fiber laser versus holmium:yttrium aluminum garnet laser for stone lithotripsy during mini-percutaneous nephrolithotomy: A prospective randomized trial. Indian J Urol 2022;38:42-7
    Jayasimha, Sudhindra
    INDIAN JOURNAL OF UROLOGY, 2022, 38 (02) : 162 - 163
  • [29] Authors reply Re: Mahajan AD, Mahajan SA. Thulium fiber laser versus holmium:yttrium aluminum garnet laser for stone lithotripsy during mini-percutaneous nephrolithotomy: A prospective randomized trial. Indian J Urol 2022;38:42-7
    Mahajan, Abhay Dinkar
    Mahajan, Sumeeta Abhay
    INDIAN JOURNAL OF UROLOGY, 2022, 38 (02) : 163 - 164
  • [30] Tantalizing thulium vs. hallowed holmium: A prospective randomized controlled trial comparing the efficacy & efficiency of thulium fiber laser and holmium: Yttrium aluminium garnet laser for stone lithotripsy during retrograde intrarenal surgery for renal calculus of 1 to 2 cm
    Nanavati, P.
    Wani, A.
    Tak, G.
    Ragoori, D.
    Reddy, P. C.
    Chiruvella, M.