Response to Wollin re: "Strike Rate: Analysis of Laser Fiber to Stone Distance During Different Modes of Laser Lithotripsy"

被引:0
|
作者
Aldoukhi, Ali H. [1 ]
Hall, Timothy L. [2 ]
Ghani, Khurshid R. [1 ]
Roberts, William W. [1 ,2 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Urol, Ann Arbor, MI 48109 USA
关键词
HOLMIUM;
D O I
10.1089/end.2021.29105.aha
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Different techniques of laser lithotripsy (fragmentation, dusting, and popcorning) are commonly used during ureteroscopy. The efficiency of a single laser pulse is dependent on minimizing laser fiber-stone distance, yet it has not been reported how often the laser fiber is in contact with the stone during laser lithotripsy. In this study, we sought to measure laser fiber to stone distance using light reflectance for each technique of laser lithotripsy. Methods: Continuous light from a 660 nm (red) light-emitting diode (LED) was coupled into a 200 μm fiber using a fiber X-coupler. The LED fiber was positioned immediately next to a 242 μm holmium fiber, and both were passed through the working channel of an ureteroscope. One fiber was used to deliver laser energy to the stone, and the other fiber was used to measure distance based on light reflected from the stone back into the fiber. For fragmentation and dusting experiments, a 5 mm BegoStone was placed into a 20 mm three-dimensional printed caliceal model. For popcorn experiments, 10 BegoStones (3 × 3 × 1.5 mm) were placed in an 11 mm caliceal model and the laser fiber positioned 2 mm away from the stone surface. Data were analyzed using a MATLAB software to report fiber to stone distance at each laser pulse. Results: With fragmentation, 52% of laser pulses were delivered when the fiber was within 0.5 mm of the stone compared to 23% and 4% for dusting and popcorning, respectively. Laser pulses delivered when fiber to stone distance was >1 mm (least effective) accounted for 34%, 48%, and >80% of total pulses during fragmentation, dusting, and popcorning, respectively. Conclusion: Current methods of laser lithotripsy that rely on fixed firing rates are inefficient, especially for the popcorn technique. These data highlight areas for improvement by appropriately gating pulse delivery to maximize lithotripsy effect for each pulse fired. © Copyright 2021, Mary Ann Liebert, Inc., publishers 2021.
引用
收藏
页码:361 / 361
页数:1
相关论文
共 34 条
  • [11] THERMAL EFFECTS OF THE SUPER-PULSE THULIUM FIBER LASER DURING URETERAL STONE LASER LITHOTRIPSY: AN IN-VIVO PORCINE STUDY
    Morgan, Kalon L.
    Jiang, Pengbo
    Peta, Akhil
    Ayad, Maged
    Bhatt, Rohit
    Brevik, Andrew
    Larson, Krista
    Okhunov, Zhamshid
    Farzeneh, Ted
    Patel, Roshan M.
    Landman, Jaime
    Clayman, Ralph V.
    JOURNAL OF UROLOGY, 2022, 207 (05): : E534 - E534
  • [12] Microscopic analysis of laser-induced proximal fiber tip damage during holmium:YAG and thulium fiber laser lithotripsy
    Wilson, Christopher R.
    Hardy, Luke A.
    Irby, Pierce B.
    Fried, Nathaniel M.
    OPTICAL ENGINEERING, 2016, 55 (04)
  • [13] Ho:YAG laser lithotripsy in non-contact mode: optimization of fiber to stone working distance to improve ablation efficiency
    De Coninck, Vincent
    Keller, Etienne Xavier
    Chiron, Paul
    Dragos, Laurian
    Emiliani, Esteban
    Doizi, Steeve
    Berthe, Laurent
    Traxer, Olivier
    WORLD JOURNAL OF UROLOGY, 2019, 37 (09) : 1933 - 1939
  • [14] Ho:YAG laser lithotripsy in non-contact mode: optimization of fiber to stone working distance to improve ablation efficiency
    Vincent De Coninck
    Etienne Xavier Keller
    Paul Chiron
    Laurian Dragos
    Esteban Emiliani
    Steeve Doizi
    Laurent Berthe
    Olivier Traxer
    World Journal of Urology, 2019, 37 : 1933 - 1939
  • [15] Optimal parameter settings of thulium fiber laser for ureteral stone lithotripsy: a comparative study in two different testing environments
    Li, Zhilong
    Wu, Shaojie
    Liu, Tongzu
    Li, Sheng
    Wang, Xinghuan
    UROLITHIASIS, 2024, 52 (01)
  • [16] Thulium fiber laser versus holmium:yttrium aluminum garnet laser for stone lithotripsy during mini-percutaneous nephrolithotomy: A prospective randomized trial
    Mahajan, Abhay Dinakar
    Mahajan, Sumeeta Abhay
    INDIAN JOURNAL OF UROLOGY, 2022, 38 (01) : 42 - 47
  • [17] Correction: Optimal parameter settings of thulium fiber laser for ureteral stone lithotripsy: a comparative study in two different testing environments
    Zhilong Li
    Shaojie Wu
    Tongzu Liu
    Sheng Li
    Xinghuan Wang
    Urolithiasis, 53 (1)
  • [18] Texture Analysis of Inconel 718 with Different Modes During Single-Track Laser Surface Re-Melting
    Yang, Liuqing
    Niu, Tongjun
    Stilgenbauer, Joe
    Lane, Brandon
    Li, Nan
    Weaver, Jordan
    Chen, Youxing
    METALS, 2025, 15 (02)
  • [19] The Effects of Scanning Speed and Standoff Distance of the Fiber on Dusting Efficiency during Short Pulse Holmium: YAG Laser Lithotripsy
    Chen, Junqin
    Li, Daiwei
    Yu, Wenjun
    Ma, Zhiteng
    Li, Chenhang
    Xiang, Gaoming
    Wu, Yuan
    Yao, Junjie
    Zhong, Pei
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)
  • [20] Comparison of Single, Dual, and Staircase Temporal Pulse Profiles for Reducing Stone Retropulsion during Thulium Fiber Laser Lithotripsy in an In Vitro Stone Phantom Model
    Gonzalez, David A.
    Giglio, Nicholas C.
    Hall, Layton A.
    Vinnichenko, Viktoriya
    Fried, Nathaniel M.
    THERAPEUTICS AND DIAGNOSTICS IN UROLOGY 2019, 2019, 10852