Energy efficiency evaluation of multiple split-system air conditioners with unbalanced load operation for building energy simulation

被引:0
|
作者
Miyata, M. [1 ]
机构
[1] Natl Inst Land & Infrastruct Management, Tsukuba, Ibaraki, Japan
关键词
D O I
10.1088/1755-1315/238/1/012082
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The number of buildings that adopt the multiple split-system air conditioners is increasing, especially for small and medium-sized buildings. Many researches have been done on the energy consumption performance of the multiple split-system, but there are still many unclear points about its actual performance, in particularly, with regard to performance under partial load condition. It is important to understand the partial load performance and set the reliable performance characteristics when we perform building energy simulation because it will have a significant influence on annual energy consumption of the system. In order to clarify the efficiency under partial load condition, we have analysed the measurement data of actual buildings and found that there is a range of the efficiency even at the same load ratio. We assume that the cause of this range is due to bias (unbalance) in the heat amount handled by multiple indoor units. The efficiency tends to be higher when the heat amount of all indoor units of the system are equal, which is same as the test condition specified by ISO 15042:2017, but the efficiency tends to be lower when the heat amount handled by the indoor units is highly unbalanced. This research clarifies the influence of the unbalanced heat load to the system energy efficiency. We measured fundamental data on the energy efficiency of the multiple split-system air-conditioner in an experimental facility that connects multiple constant temperature and humidity chambers. We found that the unbalanced load operation caused about 20% energy loss in maximum and concluded that the indoor units should be arranged so that extreme unbalanced heat load does not occur.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Energy performance evaluation and application of an air treatment system for conditioning building spaces in tropics
    Cui, X.
    Mohan, B.
    Islam, M. R.
    Chou, S. K.
    Chua, K. J.
    APPLIED ENERGY, 2017, 204 : 1500 - 1512
  • [42] Simulation and experimental research on energy conversion efficiency of scroll expander for micro-Compressed Air Energy Storage system
    Yang Xinghua
    Pan Jiazhen
    Wang Jidai
    Sun Jing
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2014, 38 (07) : 884 - 895
  • [43] Verification of energy efficiency of district heating and cooling system by simulation considering design and operation parameters
    Shimoda, Yoshlyuki
    Nagota, Tomoji
    Isayama, Naoaki
    Mizuno, Minoru
    BUILDING AND ENVIRONMENT, 2008, 43 (04) : 569 - 577
  • [44] Intelligent operation, maintenance, and control system for public building: Towards infection risk mitigation and energy efficiency
    Ren, Chen
    Zhu, Hao-Cheng
    Wang, Junqi
    Feng, Zhuangbo
    Chen, Gang
    Haghighat, Fariborz
    Cao, Shi-Jie
    SUSTAINABLE CITIES AND SOCIETY, 2023, 93
  • [45] The Evaluation Index System and Method of Economic and Operation Efficiency for the Power Transmission System Containing Intermittent Energy
    Fang, Yujuan
    Wang, Xiuli
    Yan, Huan
    Wei, Lei
    Wu, Xiong
    Dang, Can
    Zhang, Yue
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [46] Energy performance evaluation of thermo-active building system based on simulation and measurement
    Muramatsu H.
    Togashi E.
    Nobe T.
    Journal of Environmental Engineering (Japan), 2019, 84 (762): : 759 - 769
  • [47] Energy efficiency evaluation for building air-conditioning systems determined by coincident design weather data
    Xiao, Rui
    Chen, Youming
    Zhang, Xinchao
    Cao, Minghao
    Fang, Zhengcheng
    JOURNAL OF BUILDING ENGINEERING, 2024, 84
  • [48] A new approach to developing building energy system simulation programs suitable for both design and optimal operation
    Sun, Jian
    Reddy, T. Agarni
    ASHRAE TRANSACTIONS 2006, VOL 112, PT 1, 2006, 112 : 729 - +
  • [49] Analysis on Energy Saving Factors and research on Energy efficiency evaluation indexes of Ventilation and Air Conditioning System in the Underground Engineering
    Geng, Shibin
    Chen, Shasha
    Xiao, Mingxing
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 682 - 687
  • [50] Evaluation and SD Simulation on Energy Use Efficiency of 3E System of China
    Tu, Guoping
    Leng, Bibin
    Jia, Ren'an
    PROCEEDINGS OF 2009 CONFERENCE ON SYSTEMS SCIENCE, MANAGEMENT SCIENCE & SYSTEM DYNAMICS, VOL 6, 2009, : 149 - 155