Energy efficiency evaluation for building air-conditioning systems determined by coincident design weather data

被引:4
|
作者
Xiao, Rui [1 ,2 ]
Chen, Youming [1 ,2 ]
Zhang, Xinchao [1 ,2 ]
Cao, Minghao [1 ,2 ]
Fang, Zhengcheng [1 ,2 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Hunan, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Coincident design day; Design weather data; Air-conditioning system design; Energy efficiency; Energy simulation; CONSUMPTION; LOAD;
D O I
10.1016/j.jobe.2024.108581
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Accurate design weather data are important for the energy efficiency of building air conditioning systems. Design cooling load of air conditioning system can be calculated accurately by coincident design day (CDD). It is important to evaluate the effect of coincident design day on the energy consumption and thermal comfort of air conditioning systems for promoting its application in engineering design. In this study, the coincident design days were determined and applied to the building's air-conditioning systems design. Using DesignBuilder simulations, cooling electricity consumption and thermal comfort performance of the proposed system have been investigated in three climate zones. A comparative assessment of the systems using coincident design days has been made against the systems using traditional design days. Results show that for the rooms with single external walls using the packaged terminal air conditioner (PTAC), the energy saved by coincident design days is 3.27%-7.19%, 1.43%-5.46%, and 2.25%-5.18% in Beijing, Changsha, and Hong Kong. For the whole buildings using fan coil with dedicated outdoor air (FCU + DOA), constant air volume (CAV), and variable air volume (VAV) systems, the energy saved by coincident design days is 11.38%-12.67%, 17.89%-17.9%, and 14.99%-16.06%, respectively in Beijing. In Changsha, these systems determined by coincident design days save energy are 11.19%-11.47%, 14.7%-17.82%, and 13.42%-16.05%. In Hong Kong, these systems determined by coincident design days save energy are 11.73%-12.48%, 17.97%-18.8%, and 14.99%-15.35%. The application of coincident design days to the CAV systems has the highest efficiency. These results demonstrate that the air conditioning systems determined by coincident design days can significantly reduce cooling energy consumption without affecting indoor thermal comfort, and fulfill the requirements of indoor thermal risk levels in the three climate zones of China.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Generation and prediction of building coincident design day for improving energy efficiency of building air conditioning systems
    Fang, Zhengcheng
    Chen, Youming
    SUSTAINABLE CITIES AND SOCIETY, 2025, 124
  • [2] Energy efficiency of cold or heat sources in air-conditioning systems & building energy conservation
    Wang, CQ
    Long, WD
    Ding, WT
    Wu, QQ
    Zhong, T
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 953 - 959
  • [4] Air-conditioning System Energy Efficiency and Energy Consumption Evaluation
    Du, Xiaotong
    Cai, Wenjian
    Jia, Lei
    2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 1908 - 1913
  • [5] Correlation between energy for air-conditioning and tall building design
    Lo, T.T.
    Chu, Chun-Ying
    Kwok, K.W.
    Lau, K.M.
    Hong Kong engineer, 1990, 18 (01):
  • [6] AIR-CONDITIONING SYSTEMS OF THE KI BUILDING
    OKAMOTO, A
    HASEGAWA, T
    TOGARI, S
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (08): : 33 - 36
  • [7] A new concept for analyzing the energy efficiency of air-conditioning systems
    Zhang, Lun
    Liu, Xiao-Hua
    Jiang, Yi
    ENERGY AND BUILDINGS, 2012, 44 : 45 - 53
  • [8] Rational selection of near-extreme coincident weather data with solar irradiation for risk-based air-conditioning design
    Chen, Tingyao
    Chen, Youming
    Yik, Francis W. H.
    ENERGY AND BUILDINGS, 2007, 39 (12) : 1193 - 1201
  • [9] Influence of climate change on weather data for heating and air-conditioning design in China
    Zhang, Qingyuan
    Huang, Joe
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 2123 - 2129
  • [10] Evaluation of four control strategies for building VAV air-conditioning systems
    Yang, Xue-Bin
    Jin, Xin-Qiao
    Du, Zhi-Min
    Fan, Bo
    Chai, Xiao-Feng
    ENERGY AND BUILDINGS, 2011, 43 (2-3) : 414 - 422