Early detection of doxorubicin myocardial injury by ultrasonic tissue characterization in an experimental animal model

被引:12
|
作者
Dias Romano, Minna Moreira [1 ]
Pazin-Filho, Antonio [1 ,2 ]
O'Connel, Joao Lucas [1 ]
Simoes, Marcus Vinicius [1 ]
Schmidt, Andre [1 ]
Campos, Erica C. [3 ]
Rossi, Marcos [3 ]
Maciel, Benedito Carlos [1 ,4 ]
机构
[1] Univ Sao Paulo, Div Cardiol, Med Sch Ribeirao Preto, Sao Paulo, Brazil
[2] Univ Sao Paulo, Div Clin Emergencies, Med Sch Ribeirao Preto, Sao Paulo, Brazil
[3] Univ Sao Paulo, Dept Internal Med, Dept Pathol, Med Sch Ribeirao Preto, Sao Paulo, Brazil
[4] Med Sch Ribeirao Preto, Div Cardiol, Dept Internal Med, BR-14048900 Ribeirao Preto, SP, Brazil
来源
CARDIOVASCULAR ULTRASOUND | 2012年 / 10卷
关键词
Doxorubicin; Ultra-sonic tissue characterization; Echocardiography; Rats; ANTHRACYCLINE-INDUCED CARDIOTOXICITY; INTEGRATED BACKSCATTER; DILATED CARDIOMYOPATHY; CYCLIC VARIATION; CANCER; CHILDREN; THERAPY; DYSFUNCTION; DOPPLER; DAMAGE;
D O I
10.1186/1476-7120-10-40
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the clinical setting, the early detection of myocardial injury induced by doxorubicin (DXR) is still considered a challenge. To assess whether ultrasonic tissue characterization (UTC) can identify early DXR-related myocardial lesions and their correlation with collagen myocardial percentages, we studied 60 rats at basal status and prospectively after 2mg/Kg/week DXR endovenous infusion. Echocardiographic examinations were conducted at baseline and at 8,10,12,14 and 16 mg/Kg DXR cumulative dose. The left ventricle ejection fraction (LVEF), shortening fraction (SF), and the UTC indices: corrected coefficient of integrated backscatter (IBS) (tissue IBS intensity/phantom IBS intensity) (CC-IBS) and the cyclic variation magnitude of this intensity curve (MCV) were measured. The variation of each parameter of study through DXR dose was expressed by the average and standard error at specific DXR dosages and those at baseline. The collagen percent (%) was calculated in six control group animals and 24 DXR group animals. CC-IBS increased (1.29 +/- 0.27 x 1.1 +/- 0.26-basal; p=0.005) and MCV decreased (9.1 +/- 2.8 x 11.02 +/- 2.6-basal; p=0.006) from 8 mg/Kg to 16mg/Kg DXR. LVEF presented only a slight but significant decrease (80.4 +/- 6.9% x 85.3 +/- 6.9%-basal, p=0.005) from 8 mg/Kg to 16 mg/Kg DXR. CC-IBS was 72.2% sensitive and 83.3% specific to detect collagen deposition of 4.24%(AUC=0.76). LVEF was not accurate to detect initial collagen deposition (AUC=0.54). In conclusion: UTC was able to early identify the DXR myocardial lesion when compared to LVEF, showing good accuracy to detect the initial collagen deposition in this experimental animal model.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] CHANGES IN MYOCARDIAL ULTRASONIC TISSUE CHARACTERIZATION IN CHILDREN AFTER ADRIAMYCIN USE
    BIGRAS, JL
    MCCRINDLE, BW
    SHIBUYA, K
    SMALLHORN, JF
    CIRCULATION, 1995, 92 (08) : 2116 - 2116
  • [42] ECHO DENSITY OF MYOCARDIAL WALL IN THE DIABETIC HEART - ULTRASONIC TISSUE CHARACTERIZATION
    DIBELLO, V
    TALARICO, L
    PICANO, E
    DIMURO, C
    LANDINI, L
    PATERNI, M
    MATTEUCCI, E
    GIUSTI, C
    GIAMPIETRO, O
    DIABETOLOGIA, 1995, 38 : A266 - A266
  • [43] Ultrasonic tissue characterization: Review of a noninvasive technique for assessing myocardial viability
    Schecter, SO
    Teichholz, LE
    Klig, V
    Goldman, ME
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (04): : 415 - 430
  • [44] High-frequency ultrasonic detection of protein crosslinking in myocardial tissue
    Hall, CS
    Wickline, SA
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1357 - 1360
  • [45] Myocardial ultrasonic tissue characterization in pediatric and adult patients with hypertrophic cardiomyopathy
    Vitale, DF
    Bonow, RO
    Calabro, R
    DeCristofaro, M
    Pacileo, G
    Caso, P
    Gerundo, G
    Bordini, C
    Losi, MA
    Rengo, C
    Rengo, F
    CIRCULATION, 1996, 94 (11) : 2826 - 2830
  • [46] Normal values in children for myocardial ultrasonic tissue characterization by integrated backscatter
    Shibuya, K
    Bigras, JL
    McCrindle, BW
    Newman, A
    Smallhorn, JF
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (04): : 353 - 361
  • [47] Dipyridamole stress ultrasonic myocardial tissue characterization in patients with Kawasaki disease
    Yu, XY
    Hashimoto, I
    Ichida, F
    Hamamichi, Y
    Uese, KI
    Tsubata, S
    Miyawaki, T
    Seto, H
    CIRCULATION, 2000, 102 (18) : 772 - 772
  • [48] Dipyridamole stress ultrasonic myocardial tissue characterization in patients with Kawasaki disease
    Yu, XY
    Hashimoto, I
    Ichida, F
    Hamamichi, Y
    Uese, K
    Tsubata, S
    Miyawaki, T
    Seto, H
    Sahn, DJ
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (07) : 682 - 690
  • [49] NORMAL ULTRASONIC MYOCARDIAL REFLECTIVITY IN HYPERTENSIVE PATIENTS - A TISSUE CHARACTERIZATION STUDY
    GIGLI, G
    LATTANZI, F
    LUCARINI, AR
    PICANO, E
    GENOVESIEBERT, A
    MARABOTTI, C
    ZUNINO, R
    MAZZARISI, A
    LANDINI, L
    IANNETTI, M
    DISTANTE, A
    HYPERTENSION, 1993, 21 (03) : 329 - 334
  • [50] Myocardial membrane injury in pediatric cardiac surgery: An animal model
    Egan, Jonathan R.
    Butler, Tanya L.
    Cole, Andrew D.
    Abraham, Smartin
    Murala, John S.
    Baines, David
    Street, Neil
    Thompson, Lance
    Biecker, Oliver
    Dittmer, John
    Cooper, Sandra
    Au, Carol G.
    North, Kathryn N.
    Winlaw, David S.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (05): : 1154 - 1162