Early detection of doxorubicin myocardial injury by ultrasonic tissue characterization in an experimental animal model

被引:12
|
作者
Dias Romano, Minna Moreira [1 ]
Pazin-Filho, Antonio [1 ,2 ]
O'Connel, Joao Lucas [1 ]
Simoes, Marcus Vinicius [1 ]
Schmidt, Andre [1 ]
Campos, Erica C. [3 ]
Rossi, Marcos [3 ]
Maciel, Benedito Carlos [1 ,4 ]
机构
[1] Univ Sao Paulo, Div Cardiol, Med Sch Ribeirao Preto, Sao Paulo, Brazil
[2] Univ Sao Paulo, Div Clin Emergencies, Med Sch Ribeirao Preto, Sao Paulo, Brazil
[3] Univ Sao Paulo, Dept Internal Med, Dept Pathol, Med Sch Ribeirao Preto, Sao Paulo, Brazil
[4] Med Sch Ribeirao Preto, Div Cardiol, Dept Internal Med, BR-14048900 Ribeirao Preto, SP, Brazil
来源
CARDIOVASCULAR ULTRASOUND | 2012年 / 10卷
关键词
Doxorubicin; Ultra-sonic tissue characterization; Echocardiography; Rats; ANTHRACYCLINE-INDUCED CARDIOTOXICITY; INTEGRATED BACKSCATTER; DILATED CARDIOMYOPATHY; CYCLIC VARIATION; CANCER; CHILDREN; THERAPY; DYSFUNCTION; DOPPLER; DAMAGE;
D O I
10.1186/1476-7120-10-40
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the clinical setting, the early detection of myocardial injury induced by doxorubicin (DXR) is still considered a challenge. To assess whether ultrasonic tissue characterization (UTC) can identify early DXR-related myocardial lesions and their correlation with collagen myocardial percentages, we studied 60 rats at basal status and prospectively after 2mg/Kg/week DXR endovenous infusion. Echocardiographic examinations were conducted at baseline and at 8,10,12,14 and 16 mg/Kg DXR cumulative dose. The left ventricle ejection fraction (LVEF), shortening fraction (SF), and the UTC indices: corrected coefficient of integrated backscatter (IBS) (tissue IBS intensity/phantom IBS intensity) (CC-IBS) and the cyclic variation magnitude of this intensity curve (MCV) were measured. The variation of each parameter of study through DXR dose was expressed by the average and standard error at specific DXR dosages and those at baseline. The collagen percent (%) was calculated in six control group animals and 24 DXR group animals. CC-IBS increased (1.29 +/- 0.27 x 1.1 +/- 0.26-basal; p=0.005) and MCV decreased (9.1 +/- 2.8 x 11.02 +/- 2.6-basal; p=0.006) from 8 mg/Kg to 16mg/Kg DXR. LVEF presented only a slight but significant decrease (80.4 +/- 6.9% x 85.3 +/- 6.9%-basal, p=0.005) from 8 mg/Kg to 16 mg/Kg DXR. CC-IBS was 72.2% sensitive and 83.3% specific to detect collagen deposition of 4.24%(AUC=0.76). LVEF was not accurate to detect initial collagen deposition (AUC=0.54). In conclusion: UTC was able to early identify the DXR myocardial lesion when compared to LVEF, showing good accuracy to detect the initial collagen deposition in this experimental animal model.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Early detection of doxorubicin-induced myocardial damage by integrated ultrasonic backscatter using acoustic densitometry methods
    Yokoyama, N
    Takeshita, S
    Ochiai, M
    Mori, M
    Kondo, K
    Maruyama, Y
    Nishimura, H
    Chikuda, I
    Isshiki, T
    Sato, T
    CIRCULATION, 2000, 102 (18) : 539 - 539
  • [22] Myocardial ultrasonic tissue characterization in patients with thyroid dysfunction
    Minna MD Romano
    Léa MZ Maciel
    Oswaldo C Almeida-Filho
    Antonio Pazin-Filho
    André Schmidt
    Benedito C Maciel
    Cardiovascular Ultrasound, 8
  • [23] ESTIMATION OF MYOCARDIAL INFARCT SIZE WITH ULTRASONIC TISSUE CHARACTERIZATION
    SAGAR, KB
    PELC, LR
    RHYNE, TL
    WARLTIER, DC
    CLINICAL RESEARCH, 1989, 37 (04): : A887 - A887
  • [24] ESTIMATION OF MYOCARDIAL INFARCT SIZE WITH ULTRASONIC TISSUE CHARACTERIZATION
    SAGAR, KB
    PELC, LR
    RHYNE, TL
    HOWARD, J
    WARLTIER, DC
    CIRCULATION, 1991, 83 (04) : 1419 - 1428
  • [25] Ultrasonic myocardial tissue characterization in patients with primary amyloidosis
    Koyama, J
    Ray, PA
    Falk, RH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 419A - 419A
  • [26] Myocardial ultrasonic tissue characterization in patients with thyroid dysfunction
    Romano, Minna M. D.
    Maciel, Lea M. Z.
    Almeida-Filho, Oswaldo C.
    Pazin-Filho, Antonio
    Schmidt, Andre
    Maciel, Benedito C.
    CARDIOVASCULAR ULTRASOUND, 2010, 8
  • [27] EARLY DETECTION OF EXTRAVASCULAR LUNG WATER IN AN INHALATION INJURY ANIMAL-MODEL
    STEWART, RJ
    YAMAGUCHI, KT
    ROWLAND, RRR
    SANTIBANEZ, AS
    RAHIMIAN, J
    BURNS, 1986, 12 (07) : 457 - 460
  • [28] Experimental study on the detection of myocardial ultrasonic integrated backscatter
    Fan, Yu
    Li, Xiang
    Cheng, Kezheng
    Bai, Jing
    Gongye Jianzhu/Industrial Construction, 28 (08): : 337 - 341
  • [29] ULTRASONIC TISSUE CHARACTERIZATION OF ACUTE CANINE MYOCARDIAL-INFARCTION
    TAK, T
    LIN, SL
    GAMAGE, N
    MAHLER, C
    STEEN, SN
    COLLETTI, P
    RAHIMTOOLA, SH
    CHANDRARATNA, PAN
    CANADIAN JOURNAL OF CARDIOLOGY, 1989, 5 (04) : 195 - 200
  • [30] Ultrasonic myocardial tissue characterization in normal and abnormal right ventricle
    Calabro, P
    Pacileo, G
    Limongelli, G
    Russo, MG
    Scognamiglio, G
    Di Salvo, G
    Calvanese, R
    Calabrò, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 398A - 398A