A High-Balance Planar SQUID Gradiometer

被引:9
|
作者
Zhang, Xue [1 ,2 ]
Zhang, Guofeng [1 ,3 ]
Wang, Yongliang [1 ,3 ]
Rong, Liangliang [1 ,3 ]
Zhang, Shulin [1 ,3 ]
Wu, Jun [1 ,3 ]
Qiu, Longqing [1 ,3 ]
Xie, Xiaoming [1 ,3 ]
Wang, Zhen [1 ,3 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Funct Mat Informat, Shanghai 200050, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Ctr Excellence Superconducting Elect, Shanghai 200050, Peoples R China
基金
中国国家自然科学基金;
关键词
Josephson device fabrication; Josephson device measurements; SQUIDs; SQUID designs and applications;
D O I
10.1109/TASC.2019.2898678
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed and fabricated SQUID gradiometers in a Nb/Al-AlOx/Nb technology using an i-line stepper combined with a mask aligner lithography. The stepper and the aligner are used to fabricate fine-scale patterns such as the Josephson junctions and large-scale patterns such as pickup coil, respectively, on the same wafer with a 4-inch diameter. The SQUID is designed as a first-order gradiometer with a dual-washer configuration. Two sets of multiturn spiral input coils with opposite directions are integrated on the washer and connected to the pickup coil to form a flux transformer. In order to improve the balance of the gradiometer, a fully symmetric configuration is introduced with a mirrored SQUID. The pickup coil is a first-order gradiometric type with a base line of 3.5 cm. The size of each loop is 12.65 mm X 11.65 mm, which results in a gradient magnetic field sensitivity of 0.25 nT/(cm.Phi(0)). The measured gradient magnetic field noise is 75 fT/(m.root Hz) in the white noise region. Moreover, a sapphire holder is used to fix and package the chip in order to maintain the high intrinsic balance (typical 10(-4)). It makes the SQUID gradiometer more attractive for an unshielded operation in noisy environments.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] HIGH-TEMPERATURE RF SQUID GRADIOMETER APPLIED TO NONDESTRUCTIVE TESTING
    FAN, CX
    LU, DF
    WONG, KW
    XIN, Y
    XU, B
    ALZAYED, NS
    CHESTER, M
    KNAPP, DE
    CRYOGENICS, 1994, 34 (08) : 667 - 670
  • [42] Baseline optimization of SQUID gradiometer for magnetocardiography
    Li Hua
    Zhang Shu-Lin
    Qiu Yang
    Zhang Yong-Sheng
    Zhang Chao-Xiang
    Kong Xiang-Yan
    Xie Xiao-Ming
    CHINESE PHYSICS B, 2015, 24 (02)
  • [43] A 24-SQUID GRADIOMETER FOR MAGNETOENCEPHALOGRAPHY
    AHLFORS, S
    AHONEN, A
    EHNHOLM, G
    HAMALAINEN, M
    ILMONIEMI, R
    KAJOLA, M
    KIVIRANTA, M
    KNUUTILA, J
    LOUNASMAA, O
    SIMOLA, J
    TESCHE, C
    VILKMAN, V
    PHYSICA B, 1990, 165 : 97 - 98
  • [44] 24-SQUID gradiometer for magnetoencephalography
    Ahlfors, S.
    Ahonen, A.
    Ehnholm, G.
    Haemaelaeinen, M.
    Ilmoniemi, R.
    Kajola, M.
    Kiviranta, M.
    Knuutila, J.
    Lounasmaa, O.V.
    Simola, J.
    Tesche, C.
    Vilkman, V.
    Physica B: Condensed Matter, 1990, 165-66 (01) : 97 - 98
  • [45] High-sensitivity gradiometer based on three high-Tc SQUID magnetometers
    Burmistrov, E. V.
    Maslennikov, Yu. V.
    Slobodchikov, V. Yu.
    Khanin, V. V.
    Snigirev, O. V.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2010, 55 (09) : 1070 - 1075
  • [46] High-sensitivity gradiometer based on three high-Tc SQUID magnetometers
    E. V. Burmistrov
    Yu. V. Maslennikov
    V. Yu. Slobodchikov
    V. V. Khanin
    O. V. Snigirev
    Journal of Communications Technology and Electronics, 2010, 55 : 1070 - 1075
  • [47] Compensated high temperature SQUID gradiometer for mobile NDE in magnetically noisy environments
    Keenan, S. T.
    Romans, E. J.
    NDT & E INTERNATIONAL, 2012, 47 : 1 - 6
  • [48] Design of a High-Tc SQUID Planer Gradiometer and Evaluation of Sensitivity Distribution
    Tanaka, Saburo
    Izu, Takashi
    Ohtani, Ryo
    Hayashi, Kanji
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)
  • [49] A SQUID gradiometer with trimmable additional positive feedback
    Takada, Y
    Tsukada, K
    Adachi, A
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (4A): : A120 - A123
  • [50] Integrated DC SQUID gradiometer for biomagnetic application
    Chinone, Kazuo
    Kasai, Naoko
    Kiryu, Shogo
    Koyanagi, Masao
    Kado, Hisasi
    Nakanisi, Masakazu
    Kosaka, Shin
    Systems and Computers in Japan, 1991, 22 (04) : 88 - 99