Position-sensitive detectors based on carrier drift using a CdTe semiconductor

被引:1
|
作者
Nishizawa, H [1 ]
Nishiura, R [1 ]
Takashima, K [1 ]
机构
[1] Mitsubishi Electr Corp, Amagasaki, Hyogo 6618661, Japan
关键词
position-sensitive detector; drift detector; carrier trapping; gamma ray imaging; cadmium telluride;
D O I
10.1016/j.nima.2003.10.112
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The current gamma-ray imaging system has the disadvantage of a very high cost due to its need for many pixels, amplifiers and control circuits to obtain high resolution. In order to reduce the cost of gamma-ray imaging detectors we propose a single-element detector which is able to obtain two-dimensional gamma-ray images, and investigate the feasibility of a one-dimensional position-sensitive detector as a first stage. A CdTe semiconductor detector was employed in the single-element position-sensing detector. Because the mobility-lifetime product for electrons is much higher than that for holes, the movement of holes can be neglected and the CdTe detector can be regarded as an electron drift detector. We made a prototype of a simply structured, one-dimensional position-sensitive detector and evaluated its performance. Consequently, it was confirmed that the position-sensitive detector with a single CdTe element and with sub-millimeter resolution was achieved at low cost. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:416 / 422
页数:7
相关论文
共 50 条
  • [21] NEW IDEAS FOR 2-DIMENSIONAL POSITION-SENSITIVE SILICON DRIFT DETECTORS
    HIJZEN, EA
    SCHOONEVELD, EM
    VANEIJK, CWE
    HOLLANDER, RW
    SARRO, PM
    VANDENBOGAARD, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1058 - 1062
  • [22] Semiconducting-polymer-based position-sensitive detectors
    Kabra, D
    Singh, TB
    Narayan, KS
    APPLIED PHYSICS LETTERS, 2004, 85 (21) : 5073 - 5075
  • [23] Position-sensitive detectors based on redshifts in photoluminescence spectra
    Tsutsumi, Yasuhiro
    Matsumura, Ryo
    Ohta, Masamichi
    Fujieda, Ichiro
    OPTICAL ENGINEERING, 2019, 58 (07)
  • [24] Hybrid Perovskite-Based Position-Sensitive Detectors
    Ashar, A. Z.
    Ganesh, N.
    Narayan, K. S.
    ADVANCED ELECTRONIC MATERIALS, 2018, 4 (02):
  • [25] Gap measurement by position-sensitive detectors
    Kim, JK
    Kim, MS
    Bae, JH
    Kwon, JH
    Lee, HB
    Jeong, SH
    APPLIED OPTICS, 2000, 39 (16) : 2584 - 2591
  • [26] MULTIPURPOSE ARRAY OF POSITION-SENSITIVE DETECTORS
    OBST, AW
    BRAITHWA.WJ
    DOSS, CR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 528 - 528
  • [27] Gap measurement by position-sensitive detectors
    Kim, Jung-Ki
    Kim, Man-Suhk
    Bae, Jong Han
    Kwon, Jin Hyuk
    Lee, Hang-Boo
    Jeong, Soo-Hoa
    Applied Optics, 2000, 39 (16): : 2584 - 2591
  • [28] FAST TIMING POSITION-SENSITIVE DETECTORS
    KLEIN, C
    TROTSCHER, J
    WOLLNIK, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2): : 146 - 147
  • [29] Noise analysis for position-sensitive detectors
    Narayanan, C
    Buckman, AB
    Busch-Vishniac, I
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (05) : 1137 - 1144
  • [30] POSITION-SENSITIVE DETECTORS AND WEISSENBERG DIFFRACTOMETERS
    PRINCE, E
    SANTORO, A
    ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 : S234 - S234