Comparison of detector performance in small 6 MV and 6 MV FFF beams using a Versa HD accelerator

被引:12
|
作者
Denia, Paula Monasor [1 ]
Castellet Garcia, Maria del Carmen [1 ]
Manjon Garcia, Carla [1 ]
Quiros Higueras, Juan David [1 ]
Blancas, Noelia de Marco [1 ]
Alandi, Jorge Bonaque [1 ]
Juan Senabre, Xavier Jordi [1 ]
Serra, Agustin Santos [1 ]
Lopez-Tarjuelo, Juan [1 ]
机构
[1] Consorcio Hosp Prov Castellon, Serv Radiofis & Protecc Radiol, Castellon De La Plana, Spain
来源
PLOS ONE | 2019年 / 14卷 / 03期
关键词
UNFLATTENED PHOTON BEAMS; OUTPUT FACTOR MEASUREMENTS; FILTER FREE BEAMS; MONTE-CARLO; DOSIMETRIC PROPERTIES; SMALL FIELDS; CLINICAL-APPLICATION; FORMALISM; DENSITY;
D O I
10.1371/journal.pone.0213253
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
1. Background & purpose Investigate the applicability of a series of detectors in small field dosimetry and the possible differences between their responses to FF and FFF beams. This work extends upon the series of detectors used by other authors to also include metal-oxide-semiconductor field-effect transistors (MOSFETs) detectors and radiochromic film. We also included a later correction of output factors (OFs) recommended by the recently published IAEA's code of practice TRS 483 on dosimetry of small static fields used in external beam radiotherapy. 2. Materials & methods The OFs, profiles, and PDDs of 6 MV and 6 MV FFF beams were measured with 11 different detectors using field sizes between 0.6 x 0.6 cm(2) and 10 x 10 cm(2). 3. Results The OFs of the FFF beams were lower than those of the FF beams for field sizes larger than 3 x 3 cm(2) but higher for field sizes smaller than 3 x 3 cm(2). After applying the IAEA's TRS 483 corrections, the final OFs were compatible with our initial results when considering uncertainties involved. Small-volume detectors are preferable for measuring the penumbra of these small fields where this attribute is higher in the crossline direction than in the inline direction. The R-100 of equivalent-quality FFF beams was higher compared to the corresponding flattened beams. 4. Conclusions We observed no difference for the dose responses between 6 MV and 6 MV FFF beams for any of the detectors. OF results, profiles and PDDs were clearly consistent with the previously published literature regarding the Versa HD linac. Correcting our first OFs, taken as ratio of detector charges, with the IAEA's TRS 483 corrections to obtain the final OFs, did not make the former significantly different.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Determination of the penumbra width of Elekta SRS cone collimator for 6 MV FF and 6 MV FFF energies using gradient-based edge detection
    Groppo, Daniela P.
    Saraiva, Crystian W. C.
    Caldas, Linda V. E.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [42] Obtaining 5MV and 8MV energies from 6MV linear accelerator and investigating the advantages of using in IMRT
    Catan, I.
    Canbolat, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S150 - S151
  • [43] COMMISSIONING OF A MONTE CARLO DOSE CALCULATION ALGORITHM FOR 6 MV AND 15 MV PHOTON BEAMS FROM A 160 MLC SIEMENS ACCELERATOR
    Zucca Aparicio, D.
    Perez Moreno, J. M.
    Fernandez-Leton, P.
    Garcia Ruiz-Zorrilla, J.
    Minambres, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S521 - S522
  • [44] Treatment planning for a 6MV FFF Halcyon linac as a replacement for a 10MV-capable Clinac
    Withers, D.
    Kidane, G.
    Farmakidis, D.
    Crees, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1073 - S1073
  • [45] A Study on Contralateral Thermoluminescent Breast Dosimetry of Tangential Breast Irradiation Using 6 MV Linear Accelerator Beams
    Moreno, Dickerson
    Lopez, Fe Alexandra
    Santacera, Raquel Irene
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2160 - 2162
  • [46] Dosimetric Data for Small Fields (Square and Stereotactic Cone) for Commissioning of 6MV FFF Beams in the RayStation Treatment Planning System
    Lee, Y.
    Kim, Y.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E754 - E754
  • [47] MEASUREMENTS OF DOSE DISTRIBUTIONS IN SMALL BEAMS OF 6 MV X-RAYS
    RICE, RK
    HANSEN, JL
    SVENSSON, GK
    SIDDON, RL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09): : 1087 - 1099
  • [48] Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams
    Cashmore, Jason
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 293 - 307
  • [49] STUDIES OF SPATIALLY MODULATED 6MV LINEAR ACCELERATOR BEAMS IN NORMAL AND TUMOUR CELLS
    Mc Garry, C.
    Butterworth, K.
    Trainor, C.
    O'Sullivan, J.
    Prise, K.
    Hounsell, A. R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S610 - S610
  • [50] Variations in skin dose using 6MV or 18MV x-ray beams
    P. K. N. Yu
    T. Cheung
    M. J. Butson
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2003, 26 (2): : 78 - 80