Determining 252Cf source strength by absolute passive neutron correlation counting

被引:14
|
作者
Croft, S. [1 ]
Henzlova, D. [2 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
Source calibration; Multiplicity counting; Neutron correlation analysis; Californium neutrons; Absolute metrology;
D O I
10.1016/j.nima.2013.02.002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Physically small, lightly encapsulated, radionuclide sources containing Cf-252 are widely used for a vast variety of industrial, medical, educational and research applications requiring a convenient source of neutrons. For many quantitative applications, such as detector efficiency calibrations, the absolute strength of the neutron emission is needed. In this work we show how, by using a neutron multiplicity counter the neutron emission rate can be obtained with high accuracy. This provides an independent and alternative way to create reference sources in-house for laboratories such as ours engaged in international safeguards metrology. The method makes use of the unique and well known properties of the Cf-252 spontaneous fission system and applies advanced neutron correlation counting methods. We lay out the foundation of the method and demonstrate it experimentally. We show that accuracy comparable to the best methods currently used by national bodies to certify neutron source strengths is possible. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 12
页数:8
相关论文
共 50 条
  • [31] AN ABSOLUTE MEASUREMENT OF NU(252CF) AND ITS RELATIONSHIP TO NEUTRON YIELD FOR FISSIONABLE MATERIALS
    DEVOLPI, A
    PORGES, KG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (02): : 759 - &
  • [32] TOF spectrum measurement of 252Cf source fission neutron and gamma ray
    College of Communication Engineering, Chongqing University, Chongqing 400044, China
    不详
    Qiangjiguang Yu Lizishu, 2009, 11 (1719-1723):
  • [33] Prompt neutron multiplicity in correlation with fragments from spontaneous fission of 252Cf
    Gook, A.
    Hambsch, F. -J.
    Vidali, M.
    PHYSICAL REVIEW C, 2014, 90 (06):
  • [34] Resistive plate chamber neutron and gamma sensitivity measurement with a 252Cf source
    Abbrescia, M
    Altieri, S
    Baratti, V
    Barnabà, O
    Belli, G
    Bruno, G
    Colaleo, A
    DeVecchi, C
    Guida, R
    Iaselli, G
    Imbres, E
    Loddo, F
    Maggi, M
    Marangelli, B
    Musitelli, G
    Nardò, R
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Ratti, S
    Riccardi, C
    Romano, F
    Torre, P
    Vicini, A
    Vitulo, P
    Volpe, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (1-2): : 101 - 109
  • [35] Shielding design studies for a neutron irradiator system based on a 252Cf source
    da Silva, AX
    Crispim, VR
    RADIATION PROTECTION DOSIMETRY, 2001, 95 (04) : 333 - 338
  • [36] New evidence of an intense scission neutron source in the 252Cf spontaneous fission
    Kornilov, NV
    Kagalenko, AB
    Poupko, SV
    Androsenko, PA
    Hambsch, FJ
    NUCLEAR PHYSICS A, 2001, 686 : 187 - 203
  • [37] Absolute Ratio 252Cf to 235U Prompt Fission Neutron Spectra
    Kornilov, N.
    Hambsch, F-J.
    NUCLEAR SCIENCE AND ENGINEERING, 2011, 168 (01) : 73 - 74
  • [38] THE SOURCE STRENGTH OF A CF-252 NEUTRON SOURCE AS A FUNCTION OF TIME
    ALBERTS, WG
    MATZKE, M
    PTB-MITTEILUNGEN, 1983, 93 (05): : 315 - 317
  • [39] Calibration of Spherical Neutron Measuring Devices with a 252Cf Source in the Neutron Calibration Room of the KAERI
    Jun, Sun-Mee
    Kim, Bong-Hwan
    Kim, Jang-Lyul
    Lee, Jai Ki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 286 - 289
  • [40] Shielding cask for a 252Cf ion source
    Baker, SI
    Moore, EF
    Pardo, RC
    Savard, G
    HEALTH PHYSICS, 2005, 89 (01): : S34 - S34