摘要
Grounding electrode electromagnetic flowmeter can reduce the loss of the measurement signal,and the conductivity lower medium can be measured if the area of the grounding electrode was increased. However, if the grounding electrode area is increased, the measurement signal will be reduced. The weight function theory of electromagnetic flow meter shows that the reason is the distribution of electromagnetic flow meter weight functions is changed by the grounding electrode, lead to the induced electromotive force every point of media in the pipeline contribution to the measuring electrode is changed. the weight function of the electromagnetic flowmeter which possesses one or two grounding electrodes was analyzed respectively, get the law of electromagnetic flowmeter output signal decreases with the increase of the grounding electrode area. Finally, the relationship of the electromagnetic flowmeter output signal and the ground electrode diameter accounted for measuring the ratio of the pipe been demonstrated. This theory and method has a certain significance to research and development grounding electrode electromagnetic flowmeter.
引用
收藏
页码:1856 / 1862
页数:7
相关论文
共 50 条
  • [41] Modelling for an Electromagnetic Groundwater Flowmeter
    Mitchell, Ben
    Hayes, Michael
    Heffernan, Bill
    [J]. 2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [42] Response analysis of electromagnetic flowmeter
    Endou, A
    [J]. NUCLEAR TECHNOLOGY, 1996, 114 (03) : 285 - 291
  • [43] AN ELECTROMAGNETIC FLOWMETER IN LATEX SERVICE
    GRUNDY, LA
    MERTZ, CW
    FANNING, RJ
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1955, 47 (12): : 2445 - 2446
  • [44] OPTIMIZED NONCONTACT ELECTROMAGNETIC FLOWMETER
    HUSSAIN, YA
    BAKER, RC
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (03): : 210 - 213
  • [45] PROBLEMS WITH AN ELECTROMAGNETIC BLOOD FLOWMETER
    HICKMAN, R
    CROSIER, JH
    SMITH, P
    IMMELMAN, EJ
    TERBLANCHE, J
    [J]. SOUTH AFRICAN MEDICAL JOURNAL, 1975, 49 (08): : 261 - 264
  • [46] DYNAMIC ACCURACY OF ELECTROMAGNETIC FLOWMETER
    OROURKE, MF
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (01) : 142 - +
  • [47] DEVELOPMENT OF ELECTROMAGNETIC BLOOD FLOWMETER
    JOCHIM, KE
    [J]. IRE TRANSACTIONS ON BIOMEDICAL ELECTRONICS, 1962, BME9 (04): : 228 - &
  • [48] AN IMPROVED PERIVASCULAR ELECTROMAGNETIC FLOWMETER
    CLARK, DM
    WYATT, DG
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1969, 7 (02): : 185 - &
  • [49] Helix grounding electrode with good grounding performance
    Zhang, Zhanlong
    Dan, Yihua
    Mei, Daojun
    Zou, Jing
    Jiang, Peiyu
    [J]. 2018 INTERNATIONAL JOINT CONFERENCE ON METALLURGICAL AND MATERIALS ENGINEERING (JCMME 2018), 2019, 277
  • [50] SOLUTION OF ELECTROMAGNETIC FLOWMETER EQUATION
    NASHED, M
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1972, 5 (05) : L33 - &