Research of Electromagnetic Flowmeter with Grounding Electrode

被引:0
|
作者
Gao, Song [1 ]
Li, Bin [1 ]
Yin, Shi Yi [1 ]
机构
[1] ShanghaiUniversity, Sch Mechatron Engn & Automat, Shanghai 200072, Peoples R China
关键词
electromagnetic flowmeter; grounding electrode; weighting function;
D O I
10.4028/www.scientific.net/AMR.712-715.1856
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Grounding electrode electromagnetic flowmeter can reduce the loss of the measurement signal,and the conductivity lower medium can be measured if the area of the grounding electrode was increased. However, if the grounding electrode area is increased, the measurement signal will be reduced. The weight function theory of electromagnetic flow meter shows that the reason is the distribution of electromagnetic flow meter weight functions is changed by the grounding electrode, lead to the induced electromotive force every point of media in the pipeline contribution to the measuring electrode is changed. the weight function of the electromagnetic flowmeter which possesses one or two grounding electrodes was analyzed respectively, get the law of electromagnetic flowmeter output signal decreases with the increase of the grounding electrode area. Finally, the relationship of the electromagnetic flowmeter output signal and the ground electrode diameter accounted for measuring the ratio of the pipe been demonstrated. This theory and method has a certain significance to research and development grounding electrode electromagnetic flowmeter.
引用
收藏
页码:1856 / 1862
页数:7
相关论文
共 50 条
  • [21] AN IMPROVED ELECTROMAGNETIC FLOWMETER
    COBBOLD, AF
    STYLES, PR
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1955, 127 (03): : P1 - P2
  • [22] IMPROVED ELECTROMAGNETIC FLOWMETER
    BALKO, B
    BERGER, RL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (01): : 129 - &
  • [23] ELECTROMAGNETIC BLOOD FLOWMETER
    WYATT, DG
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (12): : 1146 - &
  • [24] ELECTROMAGNETIC DIFFERENTIAL FLOWMETER
    GRAY, JO
    SANDERSON, ML
    [J]. ELECTRONICS LETTERS, 1970, 6 (07) : 194 - +
  • [25] Managing electromagnetic fields from residential electrode grounding systems: A predecision analysis
    vonWinterfeldt, D
    Trauger, T
    [J]. BIOELECTROMAGNETICS, 1996, 17 (02) : 71 - 84
  • [26] Managing electromagnetic fields from residential electrode grounding systems: A predecision analysis
    University of Southern California, Inst. of Safety and Syst. Management, University Park, Los Angeles, CA, United States
    不详
    [J]. Bioelectromagnetics, 2 (71-84):
  • [27] PEA Electromagnetic Distortion Reduction by Impedance Grounding and Pulsed Voltage Electrode Configurations
    Escurra, Guillermo Mier
    Mor, Armando Rodrigo
    Castro, Luis Carlos
    Vaessen, Peter
    [J]. SENSORS, 2021, 21 (17)
  • [28] EXPERIMENTAL RESEARCH OF ELECTROMAGNETIC DISTURBANCES RELATED WITH SUBSTATION GROUNDING CONTOUR
    Bagdanavicius, Nerijus
    Dauksys, Gediminas
    Gvozdas, Vitalijus
    Maslauskaite, Gintvile
    Kryksin, Pavel Vasiljevich
    [J]. ELECTRICAL AND CONTROL TECHNOLOGIES, 2012, : 261 - +
  • [29] Research on the influence of ac current overflowing on grounding electrode corrosion
    Liu, Guohua
    Wu, Zhen
    Li, Wei
    Zhang, Zhanlong
    Mei, Daojun
    [J]. 2017 2ND INTERNATIONAL SEMINAR ON ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2017, 231
  • [30] Research for impulse current and voltage distribution of extended grounding electrode
    Xia, Changzheng
    Chen, Cixuan
    Wen, Xishan
    [J]. Gaodianya Jishu/High Voltage Engineering, 2002, 28 (05):