Cartilage imaging at 3.0T with gradient refocused acquisition in the steady-state (GRASS) and IDEAL fat-water separation

被引:18
|
作者
Kijowski, Richard [1 ]
Tuite, Michael [1 ]
Passov, Leo [1 ]
Shimakawa, Ann [2 ]
Hu, Huanzhou [3 ]
Reeder, Scott B. [1 ,3 ,4 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Gen Elect Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[4] Univ Wisconsin, Dept Med, Madison, WI USA
关键词
IDEAL; fat-water separation; magnetic resonance imaging; cartilage; knee;
D O I
10.1002/jmri.21414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate the feasibility of evaluating the articular cartilage of the knee joint at 3.0T using gradient refocused acquisition in the steady-state (GRASS) and iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) fat-water separation. Materials and Methods: Bloch equation simulations and a clinical pilot study (n = 10 knees) were performed to determine the influence of flip angle of the IDEAL-GRASS sequence on the signal-to-noise ratio (SNR) of cartilage and synovial fluid and the contrast-to-noise ratio (CNR) between cartilage and synovial fluid at 3.0T. The optimized IDEAL-GRASS sequence was then performed on 30 symptomatic patients as part of the routine 3.0T knee MRI examination at our institution. Results: The optimal flip angle was 50 degrees for IDEAL-GRASS cartilage imaging, which maximized contrast between cartilage and synovial fluid. The IDEAL-GRASS sequence consistently produced high-quality fat- and water-separated images of the knee with bright synovial fluid and 0.39 X 0.67 X 1.0 mm resolution in 5 minutes. IDEAL-GRASS images had high cartilage SNR and high contrast between cartilage and adjacent joint structures. The IDEAL-GRASS sequence provided excellent visualization of cartilage lesions in all patients. Conclusion: The IDEAL-GRASS sequence shows promise for use as a morphologic cartilage imaging sequence at 3.0T.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [41] Three-Dimensional Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) Score Assessed With an Isotropic Three-Dimensional True Fast Imaging With Steady-State Precession Sequence at 3.0 Tesla
    Welsch, Goetz H.
    Zak, Lukas
    Mamisch, Tallal C.
    Resinger, Christoph
    Marlovits, Stefan
    Trattnig, Siegfried
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 603 - 612
  • [42] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T:: comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schröder, RJ
    ACTA RADIOLOGICA, 2005, 46 (01) : 67 - 73
  • [43] 90°-Flip-angle three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee: Isovoxel cartilage imaging at 3 T
    Moriya, Susumu
    Miki, Yukio
    Kanagaki, Mitsunori
    Matsuno, Yukako
    Miyati, Tosiaki
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (08) : 1429 - 1432
  • [44] Assessment of internal auditory canal tumors: A comparison of contrast-enhanced T1-weighted and steady-state T2-weighted gradient-echo MR imaging
    Schmalbrock, P
    Chakeres, DW
    Monroe, JW
    Saraswat, A
    Miles, BA
    Welling, DB
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (07) : 1207 - 1213
  • [45] A steady-state MR fingerprinting sequence optimization framework applied to the fast 3D quantification of fat fraction and water T1 in the thigh muscles
    Slioussarenko, Constantin
    Baudin, Pierre-Yves
    Marty, Benjamin
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (06) : 2623 - 2639
  • [46] Comparison of T2 Weighted, Fat-Suppressed T2 Weighted, and Three-Dimensional (3D) Fast Imaging Employing Steady-State Acquisition (FIESTA-C) Sequences in the Temporomandibular Joint (TMJ) Evaluation
    Aksoy, Secil
    Orhan, Kaan
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [47] 3D Double-Echo Steady-State with Water Excitation MR Imaging of the Intraparotid Facial Nerve at 1.5T: A Pilot Study
    Qin, Y.
    Zhang, J.
    Li, P.
    Wang, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1167 - 1172
  • [48] Comparison of T1rho imaging between spoiled gradient echo (SPGR) and balanced steady state free precession (b-FFE) sequence of knee cartilage at 3T MRI
    Nozaki, Taiki
    Kaneko, Yasuhito
    Yu, Hon J.
    Kaneshiro, Kayleigh
    Schwarzkopf, Ran
    Yoshioka, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (07) : 1299 - 1305
  • [49] Three-dimensional-fast imaging employing steady-state acquisition and T2-weighted fast spin-echo magnetic resonance sequences on visualization of cranial nerves Ⅲ-Ⅻ
    CHENG Yushu ZHOU Zhengrong PENG Weijun TANG Feng Department of Diagnostic RadiologyCancer HospitalFudan UniversityShanghai China
    中华医学杂志(英文版), 2008, (03) : 276 - 279
  • [50] Difference in enhancement between spin echo and 3-dimensional fast spoiled gradient recalled acquisition in steady state magnetic resonance Imaging of brain metastasis at 3-T magnetic resonance imaging
    Furutani, Kaori
    Harada, Masafumi
    Mawlan, Mahmut
    Nishitani, Hiromu
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (02) : 313 - 319