Cartilage imaging at 3.0T with gradient refocused acquisition in the steady-state (GRASS) and IDEAL fat-water separation

被引:18
|
作者
Kijowski, Richard [1 ]
Tuite, Michael [1 ]
Passov, Leo [1 ]
Shimakawa, Ann [2 ]
Hu, Huanzhou [3 ]
Reeder, Scott B. [1 ,3 ,4 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Gen Elect Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[4] Univ Wisconsin, Dept Med, Madison, WI USA
关键词
IDEAL; fat-water separation; magnetic resonance imaging; cartilage; knee;
D O I
10.1002/jmri.21414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate the feasibility of evaluating the articular cartilage of the knee joint at 3.0T using gradient refocused acquisition in the steady-state (GRASS) and iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) fat-water separation. Materials and Methods: Bloch equation simulations and a clinical pilot study (n = 10 knees) were performed to determine the influence of flip angle of the IDEAL-GRASS sequence on the signal-to-noise ratio (SNR) of cartilage and synovial fluid and the contrast-to-noise ratio (CNR) between cartilage and synovial fluid at 3.0T. The optimized IDEAL-GRASS sequence was then performed on 30 symptomatic patients as part of the routine 3.0T knee MRI examination at our institution. Results: The optimal flip angle was 50 degrees for IDEAL-GRASS cartilage imaging, which maximized contrast between cartilage and synovial fluid. The IDEAL-GRASS sequence consistently produced high-quality fat- and water-separated images of the knee with bright synovial fluid and 0.39 X 0.67 X 1.0 mm resolution in 5 minutes. IDEAL-GRASS images had high cartilage SNR and high contrast between cartilage and adjacent joint structures. The IDEAL-GRASS sequence provided excellent visualization of cartilage lesions in all patients. Conclusion: The IDEAL-GRASS sequence shows promise for use as a morphologic cartilage imaging sequence at 3.0T.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [31] MR imaging of articular cartilage at 1.5T and 3.0T: comparison of IDEAL 2D FSE and 3D SPGR with fat-saturated 2D FSE and 3D SPGR in a porcine model
    Cha, Jang Gyu
    Yoo, Jae Ho
    Rhee, Sun Jung
    Hwang, Seung Sik
    Han, Jong Kyu
    ACTA RADIOLOGICA, 2014, 55 (04) : 462 - 469
  • [32] MR assessment of left ventricular function: Quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique
    Li, W
    Stern, JS
    Mai, VM
    Pierchala, LN
    Edelman, RR
    Prasad, PV
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (05) : 559 - 564
  • [33] The Role of Fast Imaging Employing Steady-State Acquisition (FIESTA) Magnetic Resonance Imaging for Assessment of Delayed Enhancement of Fat Graft Packing on Postoperative Imaging After Vestibular Schwannoma Surgery
    Kamal, Naveed
    Reddy, Renuka K.
    Kohli, Gurkirat
    Lee, Huey-Jen
    Ying, Yu-Lan Mary
    Jyung, Robert W.
    Liu, James K.
    WORLD NEUROSURGERY, 2018, 114 : E1066 - E1072
  • [34] Fat-water separation by fast metabolite cycling magnetic resonance spectroscopic imaging at 3 T: A method to generate separate quantitative distribution maps of musculoskeletal lipid components
    Alhulail, Ahmad A.
    Patterson, Debra A.
    Xia, Pingyu
    Zhou, Xiaopeng
    Lin, Chen
    Thomas, M. Albert
    Dydak, Ulrike
    Emir, Uzay E.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1126 - 1139
  • [35] A Comparative Quantitative Analysis of IDEAL (Iterative Decomposition of Water and Fat with Echo Asymmetry and Least Squares Estimation) and CHESS (Chemical Shift Selection Suppression) Technique in 3.0T Musculoskeletal MRI
    Kim, Myoung-Hoon
    Cho, Jae-Hwan
    Shin, Seong-Gyu
    Dong, Kyung-Rae
    Chung, Woon-Kwan
    Park, Tae-Hyun
    Ahn, Jae-Ouk
    Park, Cheol-Soo
    Jang, Hyon-Chol
    Kim, Yoon-Shin
    JOURNAL OF MAGNETICS, 2012, 17 (02) : 145 - 152
  • [36] T2-Weighted 3D Fast Spin Echo Imaging With Water-Fat Separation in a Single Acquisition
    Madhuranthakam, Ananth J.
    Yu, Huanzhou
    Shimakawa, Ann
    Busse, Reed F.
    Smith, Martin P.
    Reeder, Scott B.
    Rofsky, Neil M.
    Brittain, Jean H.
    McKenzie, Charles A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (03) : 745 - 751
  • [37] Dural attachment of intracranial meningiomas: evaluation with contrast-enhanced three-dimensional fast imaging with steady-state acquisition (FIESTA) at 3 T
    Junkoh Yamamoto
    Shingo Kakeda
    Mayu Takahashi
    Yuichi Aoyama
    Yoshiteru Soejima
    Takeshi Saito
    Daisuke Akiba
    Yukunori Korogi
    Shigeru Nishizawa
    Neuroradiology, 2011, 53 : 413 - 423
  • [38] Dural attachment of intracranial meningiomas: evaluation with contrast-enhanced three-dimensional fast imaging with steady-state acquisition (FIESTA) at 3 T
    Yamamoto, Junkoh
    Kakeda, Shingo
    Takahashi, Mayu
    Aoyama, Yuichi
    Soejima, Yoshiteru
    Saito, Takeshi
    Akiba, Daisuke
    Korogi, Yukunori
    Nishizawa, Shigeru
    NEURORADIOLOGY, 2011, 53 (06) : 413 - 423
  • [39] QUANTITATIVE MAGNETIC-RESONANCE-IMAGING OF HUMAN BRAIN PERFUSION AT 1.5-T USING STEADY-STATE INVERSION OF ARTERIAL WATER
    ROBERTS, DA
    DETRE, JA
    BOLINGER, L
    INSKO, EK
    LEIGH, JS
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (01) : 33 - 37
  • [40] T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation
    Reeder, Scott B.
    Yu, Huanzhou
    Johnson, Jane W.
    Shimakawa, Ann
    Brittain, Jean H.
    Pelc, Norbert J.
    Beaulieu, Christopher F.
    Gold, Garry E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 825 - 832