Design and Fabrication of a CdMnTe Nuclear Radiation Detection System

被引:1
|
作者
Egarievwe, Stephen U. [1 ]
Israel, Mordecai B. [1 ]
Banks, Alex D. [1 ]
Drabo, Mebougna L. [1 ]
Dunning, Keiandrea L. [1 ]
Cook, Vintrell J. [1 ]
Johnson, Frederick D. [1 ]
Palmer, Shaunay M. [1 ]
Roy, Utpal N. [2 ]
James, Ralph B. [3 ]
机构
[1] Alabama A&M Univ, Dept Elect Engn, Normal, AL 35762 USA
[2] Brookhaven Natl Lab, Dept Noneproliferat & Natl Secur, Upton, NY 11973 USA
[3] Savannah River Natl Lab, Sci & Technol, Aiken, SC USA
来源
2019 IEEE SOUTHEASTCON | 2019年
关键词
CdMnTe nuclear detectors; gamma-rays; X-rays; CDZNTE X-RAY; CONTACTS; PERFORMANCE;
D O I
10.1109/southeastcon42311.2019.9020612
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Cadmium manganese telluride (CdMnTe) is one of the ternary compounds of cadmium telluride (CdTe) that has shown great potential applications in the development of X-ray and gamma-ray detectors used in medical imaging and in the detection of radiological and nuclear threats. CdMnTe nuclear detectors are capable of operating at room temperature without cryogenic cooling. The goal of this project is to design and fabricate CdMnTe detection system that can be used in laboratory experiments for characterizing detector materials and for identification of radionuclides. The engineering design objectives include a spring-based sample holder, ability to measure electrical properties of CdTe-based semiconductor nuclear detectors, and the detection of nuclear radiations. This paper presents the design of the sample holder and the fabrication of a CdMnTe detector. The current-voltage characterization experimental results showed that the CdMnTe has the high resistivity needed for CdTe-based nuclear detectors. The results also include the response of the CdiVInTe detector to the 59.5-keV gamma peak of Am-241 nuclear radiation source.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Defects in CdMnTe crystals for nuclear detector applications
    杜园园
    介万奇
    徐亚东
    郑昕
    王涛
    于晖
    Journal of Semiconductors, 2013, 34 (04) : 15 - 19
  • [22] Defects in CdMnTe crystals for nuclear detector applications
    Du, Yuanyuan
    Jie, Wanqi
    Xu, Yadong
    Zheng, Xin
    Wang, Tao
    Yu, Hui
    JOURNAL OF SEMICONDUCTORS, 2013, 34 (04)
  • [23] Charge transport properties of CdMnTe radiation detectors
    Rafiei, R.
    Boardman, D.
    Reinhard, M. I.
    Sarbutt, A.
    Kim, K.
    Watt, G. C.
    Uxa, S.
    Prokopovich, D. A.
    Belas, E.
    Bolotnikov, A. E.
    James, R. B.
    HEAVY ION ACCELERATOR SYMPOSIUM ON FUNDAMENTAL AND APPLIED SCIENCE 2012, 2012, 35
  • [24] COMPUTER-BASED NUCLEAR RADIATION DETECTION AND INSTRUMENTATION TEACHING LABORATORY SYSTEM
    ELLIS, WH
    HE, Q
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 675 - 679
  • [25] Development of a Portable ZigBee-based Nuclear Radiation Monitoring and Detection System
    Ding, Fei
    Tong, En
    Song, Aiguo
    Li, Jianqing
    Song, Guangming
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 2639 - +
  • [26] Radiation Safety System and Its Design Coordination for Nuclear-Powered Ship
    Lin X.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (05): : 1 - 5
  • [27] DESIGN OF THE AREA RADIATION MONITORING SYSTEM IN NUCLEAR ISLAND OF HTR-PM
    Xie, Feng
    Kong, Jiaji
    Liu, Hongqi
    Cao, Jianzhu
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 2, 2017,
  • [28] Fabrication and characterisation of dry etched CdTe/CdMnTe quantum dots
    Ribayrol, A
    Tang, YS
    Zhou, HP
    Coquillat, D
    Torres, CMS
    Lascaray, JP
    Lunn, B
    Ashenford, DE
    Feuillet, G
    Cibert, J
    JOURNAL OF CRYSTAL GROWTH, 1996, 159 (1-4) : 434 - 437
  • [29] Design of Nuclear Radiation Monitoring System in Floor Exploration Based on Deep Learning
    Zong, Bochen
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2022, 2022
  • [30] Carbon Coating and Defects in CdZnTe and CdMnTe Nuclear Detectors
    Egarievwe, Stephen U.
    Chan, Wing
    Kim, Ki Hyun
    Roy, Utpal N.
    Sams, Valissa
    Hossain, Anwar
    Kassu, Aschalew
    James, Ralph B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 236 - 245