Validity and Reliability of the Ergomo®pro Powermeter

被引:14
|
作者
Kirkland, A. [3 ]
Coleman, D. [1 ]
Wiles, J. D. [1 ]
Hoper, J. [2 ]
机构
[1] Canterbury Christ Church Univ, Canterbury CT1 1QU, Kent, England
[2] Univ Kent, Ctr Sport Studies, Medway, England
[3] Scottish Inst Sport, Stirling, Scotland
关键词
bilateral; ergometry; reliability; SRM;
D O I
10.1055/s-2008-1038621
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this investigation was to assess the validity and reliability of the Ergomo (R) pro powermeter. Nine participants completed trials on a Monark ergometer fitted with Ergomo (R) pro and SRM powermeters simultaneously recording power output. Each participant completed multiple trials at power Outputs ranging from 50 to 450 W. The work stages recorded were 60 s in duration and were repeated three times. Participants also completed a single trial on a cycle ergometer designed to assess bilateral contributions to work Output (Lode Excaliber Sport PFM). The power output during the trials was significantly different between all three systems, (p<0.01) 231.2 +/- 114.2W, 233.0 +/- 112.4W, 227.8 +/- 108.8W for the Monark, SRM and Ergomo (R) pro system, respectively. When the bilateral contributions were factored into the analysis, there were no significant differences between the powermeters (p = 0.58). The reliability of the Ergomo (R) pro system (CV%) was 2.31% (95% CI 2.13-2.52%) compared to 1.59% (95% CI 1.47 to 1.74%) for the Monark, and 1.37% (95% CI 1.26-1.50%) for the SRM powermeter. These results indicate that the Ergomo (R) pro system has acceptable accuracy under these conditions. However, based on the reliability data, the increased variability of the Ergomo (R) pro system and bilateral balance issues have to be considered when using this device.
引用
收藏
页码:913 / 916
页数:4
相关论文
共 50 条
  • [41] Validity and reliability of an inertial device (WIMU PRO™) to quantify physical activity level through steps measurement
    Hernandez-Belmonte, Alejandro
    Bastida-Castillo, Alejandro
    Gomez-Carmona, Carlos D.
    Pino-Ortega, Jose
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2019, 59 (04): : 587 - 592
  • [42] Adherence to treatment in a Western European paediatric population with haemophilia: reliability and validity of the VERITAS-Pro scale
    Lock, J.
    Raat, H.
    Duncan, N.
    Shapiro, A.
    Beijlevelt, M.
    Peters, M.
    Tamminga, R. Y. J.
    Leebeek, F. W. G.
    Moll, H. A.
    Cnossen, M. H.
    HAEMOPHILIA, 2014, 20 (05) : 616 - 623
  • [43] Validity and Reliability of Polar Team Pro and Playermaker for Estimating Running Distance and Speed in Indoor and Outdoor Conditions
    Sandmael, Simen
    van den Tillaar, Roland
    Dalen, Terje
    SENSORS, 2023, 23 (19)
  • [44] Validity and reliability of Polar Team Pro GPS units for assessing maximum sprint speed in soccer players
    Sagiroglu, Isa
    Akyildiz, Zeki
    Yildiz, Mehmet
    Clemente, Filipe Manuel
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2023, 237 (04) : 309 - 316
  • [45] The reliability and validity of the outcome questionnaire
    Lambert, MJ
    Burlingame, GM
    Umphress, V
    Hansen, NB
    Vermeersch, DA
    Clouse, GC
    Yanchar, SC
    CLINICAL PSYCHOLOGY & PSYCHOTHERAPY, 1996, 3 (04) : 249 - 258
  • [46] RELIABILITY AND VALIDITY OF THE DICA - REPLY
    REICH, W
    WELNER, Z
    JOURNAL OF THE AMERICAN ACADEMY OF CHILD AND ADOLESCENT PSYCHIATRY, 1988, 27 (02): : 261 - 262
  • [47] A Test of the Reliability and Validity of ICCS
    姚文娟
    科技信息, 2012, (08) : 195 - 196
  • [48] Concurrent validity and reliability studies
    Petruzzello, SJ
    Hall, EE
    Ekkekakis, P
    JOURNAL OF SPORT & EXERCISE PSYCHOLOGY, 2001, 23 : S10 - S11
  • [49] Reliability and validity in ataxia scales
    De Rosa, A
    Scarano, V
    Salvatore, E
    de Falco, A
    Coppola, G
    Filla, A
    MOVEMENT DISORDERS, 2004, 19 : S23 - S23
  • [50] RELIABILITY AND VALIDITY OF VIDEOKERATOSCOPIC MEASUREMENTS
    HEATH, GG
    GERSTMAN, DR
    WHEELER, WH
    SONI, PS
    HORNER, DG