Validity and Reliability of the Ergomo®pro Powermeter

被引:14
|
作者
Kirkland, A. [3 ]
Coleman, D. [1 ]
Wiles, J. D. [1 ]
Hoper, J. [2 ]
机构
[1] Canterbury Christ Church Univ, Canterbury CT1 1QU, Kent, England
[2] Univ Kent, Ctr Sport Studies, Medway, England
[3] Scottish Inst Sport, Stirling, Scotland
关键词
bilateral; ergometry; reliability; SRM;
D O I
10.1055/s-2008-1038621
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this investigation was to assess the validity and reliability of the Ergomo (R) pro powermeter. Nine participants completed trials on a Monark ergometer fitted with Ergomo (R) pro and SRM powermeters simultaneously recording power output. Each participant completed multiple trials at power Outputs ranging from 50 to 450 W. The work stages recorded were 60 s in duration and were repeated three times. Participants also completed a single trial on a cycle ergometer designed to assess bilateral contributions to work Output (Lode Excaliber Sport PFM). The power output during the trials was significantly different between all three systems, (p<0.01) 231.2 +/- 114.2W, 233.0 +/- 112.4W, 227.8 +/- 108.8W for the Monark, SRM and Ergomo (R) pro system, respectively. When the bilateral contributions were factored into the analysis, there were no significant differences between the powermeters (p = 0.58). The reliability of the Ergomo (R) pro system (CV%) was 2.31% (95% CI 2.13-2.52%) compared to 1.59% (95% CI 1.47 to 1.74%) for the Monark, and 1.37% (95% CI 1.26-1.50%) for the SRM powermeter. These results indicate that the Ergomo (R) pro system has acceptable accuracy under these conditions. However, based on the reliability data, the increased variability of the Ergomo (R) pro system and bilateral balance issues have to be considered when using this device.
引用
收藏
页码:913 / 916
页数:4
相关论文
共 50 条
  • [11] Reliability and validity of Polar Team Pro measurements in running at different velocities in an indoor setting
    van den Tillaar, Roland
    Pettersen, Fredrik Gaustad
    Lagestad, Pal
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2023, 5
  • [12] Test-retest reliability and construct validity of the Pro-Environmental Behavior Task
    Lange, Florian
    Dewitte, Siegfried
    JOURNAL OF ENVIRONMENTAL PSYCHOLOGY, 2021, 73
  • [13] Validity and Reliability
    Emerson, Robert Wall
    JOURNAL OF VISUAL IMPAIRMENT & BLINDNESS, 2024, 118 (04) : 280 - 281
  • [14] Reliability and validity
    Hernon, Peter
    Schwartz, Candy
    LIBRARY & INFORMATION SCIENCE RESEARCH, 2009, 31 (02) : 73 - 74
  • [15] RELIABILITY OR VALIDITY
    STEWART, RG
    ADMINISTRATIVE SCIENCE QUARTERLY, 1979, 24 (02) : 312 - 313
  • [16] RELIABILITY AND VALIDITY
    Prieto, Gerardo
    Delgado, Ana R.
    PAPELES DEL PSICOLOGO, 2010, 31 (01): : 67 - 74
  • [17] Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements
    Joshua M. Drouin
    Tamara C. Valovich-mcLeod
    Sandra J. Shultz
    Bruce M. Gansneder
    David H. Perrin
    European Journal of Applied Physiology, 2004, 91 : 22 - 29
  • [18] Reliability and validity of PRO-CTCAE® daily reporting with a 24-hour recall period
    Lee, M. K.
    Basch, E.
    Mitchell, S. A.
    Minasian, L. M.
    Langlais, B. T.
    Thanarajasingam, G.
    Ginos, B. F.
    Rogak, L. J.
    Mendoza, T. R.
    Bennett, A. V.
    Schrag, D.
    Mazza, G. L.
    Dueck, A. C.
    QUALITY OF LIFE RESEARCH, 2023, 32 (07) : 2047 - 2058
  • [19] Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements
    Drouin, JM
    Valovich-mcLeod, TC
    Shultz, SJ
    Gansneder, BM
    Perrin, DH
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 91 (01) : 22 - 29
  • [20] Validity and reliability of smartphone-based Goniometer-Pro app for measuring the thoracic kyphosis
    Shahri, Yasin Faramarzi Kohneh
    Hesar, Narmin Ghani Zadeh
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2020, 49