Detecting Patient Motion in Projection Space for Cone-beam Computed Tomography

被引:0
|
作者
Wein, Wolfgang [1 ]
Ladikos, Alexander [1 ]
机构
[1] White Lion Technol AG, Munich, Germany
关键词
REGISTRATION; CT;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Cone-beam X-Ray systems strictly depend on the imaged object being stationary over the entire acquisition process. Even slight patient motion can affect the quality of the final 3D reconstruction. It would be desirable to be able to discover and model patient motion right from the actual projection images, in order to take it into account during reconstruction. However, while the source-detector arrangement is rotating around the patient, it is difficult to separate this motion from the additional patient motion. We present a novel similarity metric for successive X-Ray projections, which is able to distinguish between the expected rotational and additional sources of motion. We quantitatively evaluate it on simulated dental cone-beam X-Rays and qualitatively demonstrate its performance on real patient data.
引用
下载
收藏
页码:516 / 523
页数:8
相关论文
共 50 条
  • [31] Evaluation of artificial intelligence for detecting periapical pathosis on cone-beam computed tomography scans
    Orhan, K.
    Bayrakdar, I. S.
    Ezhov, M.
    Kravtsov, A.
    Ozyurek, T.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (05) : 680 - 689
  • [32] Accuracy of Cone-Beam Computed Tomography and Periapical Radiography in Detecting Small Periapical Lesions
    Tsai, Patrick
    Torabinejad, Mahmoud
    Rice, Dwight
    Azevedo, Bruno
    JOURNAL OF ENDODONTICS, 2012, 38 (07) : 965 - 970
  • [33] COMPARISON OF CONE-BEAM COMPUTED TOMOGRAPHY AND PANORAMIC RADIOGRAPHS IN DETECTING MAXILLARY SINUS SEPTA
    Toraman-Alkurt, Meryem
    Peker, Ilkay
    Degerli, Serife
    Cebeci, Ali Riza Ilker
    Sadik, Elif
    JOURNAL OF ISTANBUL UNIVERSITY FACULTY OF DENTISTRY, 2016, 50 (03) : 8 - 14
  • [34] Comparison of kilovoltage cone-beam computed tomography with megavoltage projection pairs for paraspinal radiosurgery patient alignment and position verification
    Kriminski, Sergey A.
    Lovelock, D. Michael
    Seshan, Venkatraman E.
    Ali, Imad
    Munro, Peter
    Amols, Howard I.
    Fuks, Zvi
    Bilsky, Mark
    Yamada, Yoshiya
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (05): : 1572 - 1580
  • [35] Comparative study of jaws with multislice computed tomography and cone-beam computed tomography
    Carrafiello, G.
    Dizonno, M.
    Colli, V.
    Strocchi, S.
    Taubert, S. Pozzi
    Leonardi, A.
    Giorgianni, A.
    Barresi, M.
    Macchi, A.
    Bracchi, E.
    Conte, L.
    Fugazzola, C.
    RADIOLOGIA MEDICA, 2010, 115 (04): : 600 - 611
  • [36] Preliminary Evaluation of the Dosimetric Accuracy of Cone-beam Computed Tomography for Cases with Respiratory Motion
    Kim, Dong Wook
    Bae, Sunhyun
    Chung, Weon Kuu
    Lee, Yoonhee
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (07) : 1070 - 1077
  • [37] Motion correction for improved target localization with on-board cone-beam computed tomography
    Li, T
    Schreibmann, E
    Yang, Y
    Xing, L
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02): : 253 - 267
  • [38] Effect of a Motion Artifact Correction System on Cone-Beam Computed Tomography Image Characteristics
    Pahadia, Mayank
    Katkar, Rujuta
    Geha, Hassem
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [39] Cone-beam Computed Tomography Evaluation of Maxillary Sinusitis
    Maillet, Michelle
    Bowles, Walter R.
    McClanahan, Scott L.
    John, Mike T.
    Ahmad, Mansur
    JOURNAL OF ENDODONTICS, 2011, 37 (06) : 753 - 757
  • [40] Practical applications of cone-beam computed tomography in orthodontics
    Mah, James K.
    Huang, John C.
    Choo, HyeRan