On-board imager (OBI) based cone-beam computed tomography (CBCT) has become available in radiotherapy clinics to accurately identify the target in the treatment position. However, due to the relatively slow gantry rotation (typically about 60 s for a full 360 degrees scan) in acquiring the CBCT projection data, the patient's respiratory motion causes serious problems such as blurring, doubling, streaking and distortion in the reconstructed images, which heavily degrade the image quality and the target localization. In this work, we present a motion compensation method for slow-rotating CBCT scans by incorporating into image reconstruction a patient-specific motion model, which is derived from previously obtained four-dimensional (4D) treatment planning CT images of the same patient via deformable registration. The registration of the 4D CT phases results in transformations representing a temporal sequence of three-dimensional (3D) deformation fields, or in other words, a 4D model of organ motion. The algorithm was developed heuristically in two-dimensional (2D) parallel-beam geometry and extended to 3D cone-beam geometry. By simulations with digital phantoms capable of translational motion and other complex motion, we demonstrated that the algorithm can reduce the motion artefacts locally, and restore the tumour size and shape, which may thereby improve the accuracy of target localization and patient positioning when CBCT is used as the treatment guidance.
引用
收藏
页码:253 / 267
页数:15
相关论文
共 50 条
  • [1] AUTOMATIC MOTION CORRECTION IN CONE-BEAM COMPUTED TOMOGRAPHY
    Ens, S.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3248 - 3251
  • [2] Motion Correction Algorithm for Cone-Beam Computed Tomography
    Lee, Jiyoung
    Kim, Jinwoo
    Cho, Minkook
    [J]. MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [3] Quality assurance of the on-board imager and cone-beam computed tomography systems
    Yoo, S.
    Kim, G.
    Hammoud, R.
    Elder, E.
    Pawlicki, T.
    Guan, H.
    Fox, T.
    Luxton, G.
    Yin, F.
    Munro, P.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2131 - 2132
  • [4] Four-dimensional cone-beam computed tomography using an on-board imager
    Li, Tianfang
    Xing, Lei
    Munro, Peter
    McGuinness, Christopher
    Chao, Ming
    Yang, Yong
    Loo, Bill
    Koong, Albert
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3825 - 3833
  • [5] Evaluation of the three dimensional localization accuracy using cone-beam computed tomography of Varian On-Board Imager (OBI)
    Zhang, L.
    Yan, H.
    Yoo, S.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2034 - 2034
  • [6] Rotational artifacts in on-board cone beam computed tomography
    Ali, E. S. M.
    Webb, R.
    Nyiri, B. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04): : 1461 - 1476
  • [7] Rotational errors with on-board cone beam computed tomography
    Ali, E. S. M.
    Webb, R.
    Nyiri, B.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 8 - 8
  • [8] A Phantom Study on Target Localization Accuracy Using Cone-Beam Computed Tomography
    Yan, Hui
    Zhang, Liwei
    Yin, Fang-Fang
    [J]. CLINICAL MEDICINE INSIGHTS-ONCOLOGY, 2008, 2 : 501 - 510
  • [9] Dose Verification of Four-Dimensional Cone-Beam Computed Tomography for Target Localization of Planned and Unplanned Target Motion
    Baley, C.
    Stathakis, S.
    Myers, P.
    Kirby, N.
    Rasmussen, K.
    Papanikolaou, N.
    Saenz, D.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E605 - E606
  • [10] Comparative study of respiratory motion correction techniques in cone-beam computed tomography
    Rit, Simon
    Nijkamp, Jasper
    van Herk, Marcel
    Sonke, Jan-Jakob
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 356 - 359