Electrochemical Immunoassay for Determination of Glycated Albumin using Nanozymes

被引:25
|
作者
Choi, Hyun [1 ]
Son, Seong Eun [1 ]
Hur, Won [1 ]
Tran, Van-Khue [1 ]
Lee, HanBeen [1 ]
Park, Yosep [1 ]
Han, Do Kyoung [2 ]
Seong, Gi Hun [1 ]
机构
[1] Hanyang Univ, Dept Bionano Engn, Ansan 426791, South Korea
[2] Korea Basic Sci Inst, Res Ctr Mat Anal, 169-148 Gwahak Ro, Daejeon 34133, South Korea
基金
新加坡国家研究基金会;
关键词
PEROXIDASE-LIKE ACTIVITY; SERUM-ALBUMIN; PLATINUM; NANOPARTICLES; GLUCOSE; GOLD; IMPROVEMENT; DIAGNOSIS;
D O I
10.1038/s41598-020-66446-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We developed a new nanozyme-based electrochemical immunoassay method for the monitoring of glycated albumin (GA) known to reflect short-term glycaemic levels. For this study, we synthesized urchin-like Pt nanozymes (uPtNZs) and applied them to colorimetric and electrochemical assays for sensitive determination of GA in total human serum albumin (tHSA) using 3,3 ',5,5 '-tetramethylbenzidine (TMB) and thionine as substrates, respectively. The uPtNZs showed peroxidase-mimic activity in the presence of hydrogen peroxide. Boronic acid (BA)-agarose bead was used to capture GA through specific cis-diol interactions. uPtNZs were modified with GA antibody (GA-Ab) to form sandwich complexes with GA/BA-agarose bead. The amount of Ab-uPtNZ/GA/BA-agarose bead complex increased with increasing percentage of GA in 50mg/mL tHSA. The colorimetric assay exhibited linearity from 0.02 to 10% (10 mu g/mL - 5mg/mL) GA with an LOD of 0.02% (9.2 mu g/mL). For electrochemical assay, GA was detected from 0.01 to 20% (5 mu g/mL - 10mg/mL) with an LOD of 0.008% (3.8 mu g/mL). The recovery values of measured GA in human plasma samples were from 106 to 107%. These results indicate that electrochemical assay using uPtNZs is a promising method for determining GA.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A QUENCHING FLUORESCENCE IMMUNOASSAY METHOD FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED TERBIUM CHELATE
    Feng Ji YAO Pei Hong LI Xiao Da YANG Bo XING Yun Xiang CI (Department of Chemistry
    Chinese Chemical Letters, 1991, (09) : 737 - 738
  • [22] VOLTAMMETRIC DETERMINATION OF LEAD LABELED ALBUMIN AND OF ALBUMIN ANTI-SERUM BY IMMUNOASSAY
    ALAM, IA
    CHRISTIAN, GD
    ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1982, 15 (18): : 1449 - 1456
  • [23] A Simple Graphene Functionalized Electrochemical Aptasensor for the Sensitive and Selective Detection of Glycated Albumin
    Aye, Nang Noon Shean
    Maraming, Pornsuda
    Tavichakorntrakool, Ratree
    Chaibunruang, Attawut
    Boonsiri, Patcharee
    Daduang, Sakda
    Teawtrakul, Nattiya
    Prasongdee, Prinya
    Amornkitbamrung, Vittaya
    Daduang, Jureerut
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [24] DETERMINATION OF NONENZYMATICALLY GLYCATED ALBUMIN AND IGG BY AFFINITY-CHROMATOGRAPHY AND COLORIMETRY
    CAINES, PSM
    THIBERT, RJ
    DRAISEY, TF
    MICROCHEMICAL JOURNAL, 1988, 37 (01) : 70 - 76
  • [25] SEMIAUTOMATED DETERMINATION OF GLYCATED ALBUMIN IN GLYCEMIC CONTROL OF DIABETIC-PATIENTS
    CABRE, M
    JOVEN, J
    SIMO, JM
    MATAS, C
    CAMPS, J
    CLINICAL BIOCHEMISTRY, 1994, 27 (04) : 307 - 309
  • [26] Polydopamine Nanoparticles Functionalized Electrochemical DNA Aptasensor for Serum Glycated Albumin Detection
    Maraming, Pornsuda
    Aye, Nang Noon Shean
    Boonsiri, Patcharee
    Daduang, Sakda
    Buhome, Onanong
    Daduang, Jureerut
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (22)
  • [27] Determination of glycated albumin using a Prussian blue nanozyme-based boronate affinity sandwich assay
    Son, Seong Eun
    Gupta, Pramod K.
    Hur, Won
    Choi, Hyun
    Lee, Han Been
    Park, Yosep
    Seong, Gi Hun
    ANALYTICA CHIMICA ACTA, 2020, 1134 : 41 - 49
  • [28] Determination of Amadori Product in Glycated Human Serum Albumin by Spectroscopy Methods
    Bohlooli, Mousa
    Ghaffari-Moghaddam, Mansour
    Khajeh, Mostafa
    Sheibani, Nader
    CHEMISTRYSELECT, 2018, 3 (24): : 7018 - 7022
  • [29] DETERMINATION OF NONENZYMATICALLY GLYCATED IGG AND ALBUMIN BY AFFINITY-CHROMATOGRAPHY AND COLORIMETRY
    CAINES, PS
    THIBERT, RJ
    DRAISEY, TF
    CLINICAL CHEMISTRY, 1986, 32 (06) : 1141 - 1141
  • [30] Evaluation of Turbidimetric Inhibition Immunoassay (TINIA) and HPLC Methods for Glycated Haemoglobin Determination
    Genc, Sema
    Omer, Beyhan
    Aycan-Ustyol, Esra
    Ince, Nurhan
    Bal, Fatih
    Gurdol, Figen
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2012, 26 (06) : 481 - 485