Influence of 2% chlorhexidine digluconate on bond strength of a glass-fibre post luted with resin or glass-ionomer based cement

被引:14
|
作者
Gadelha de Araujo, Diana Ferreira [1 ]
Chaves, Larissa Pinceli [1 ]
Bim Junior, Odair [1 ]
Pimentel Garcia, Fernanda Cristina [2 ]
Ishikiriama, Sergio Kiyoshi [1 ]
Honorio, Heitor Marques [3 ]
Wang, Linda [1 ]
机构
[1] Univ Sao Paulo, Dept Operat Dent Endodont & Dent Mat, Bauru Sch Dent, Bauru, SP, Brazil
[2] Univ Brasilia UnB, Dent Mat Area, Dept Restorat Dent, Brasilia, DF, Brazil
[3] Univ Sao Paulo, Bauru Sch Dent, Dept Pediat Dent Orthodont & Collect Hlth, Bauru, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Bond strength; Chlorhexidine; Dual-cure resin cement; Resin-modified glass-ionomer cement; Root canal; ROOT DENTIN; HYGROSCOPIC EXPANSION; TEETH; ADHESION; RESISTANCE;
D O I
10.1016/j.jdent.2014.02.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the influence of 2% chlorhexidine digluconate (CHX) on the bond strength (BS) of a glass-fibre post to the root canal, regarding the cements (dual-cured resin or resin-modified glass-ionomer cement), the root thirds and the time of storage. Method: Eighty bovine roots were selected and endodontically treated, before being randomly assigned to the following groups according to the luting protocol: ARC (RelyX ARC); ARC + CHX; RL (RelyX Luting 2); and RL + CHX. After 24 h of luting, the roots were sliced to obtain 1 mm-thick slices. Half of each group was submitted to either 7-day or 6-month storage in artificial saliva (n = 10). The specimens were subjected to push-out tests with a crosshead speed of 0.5 mm/min. The data were analysed with four-way ANOVA and Tukey's test (P <= 0.05). The failure modes were analysed with a digital microscope (50 x and 200x). Results: ARC yielded a significantly higher BS compared to RL (P < 0.001). Despite CHX exerted a significant effect; it depends on the interaction with the luting cement and time (P < 0.001). Thus, CHX decreased the values of BS to those of ARC after 6 months (P < 0.001). On the 7th day of storage, the ARC + CHX presented higher BS to the cervical and middle thirds compared to RL + CHX (P = 0.012). Time solely was not a significant factor (P = 0.081). Adhesive cement-dentine type and mixed failures were predominant modes for the ARC groups. For the RL groups, the main failures were adhesive cement-post and mixed modes. Conclusions: Glass-fibre posts luted with RelyX ARC dual-cure resin cement exhibited higher BS than those luted with RelyX Luting 2 resin-modified glass-ionomer cement. Furthermore, CHX was not effective to improve the BS and negatively affected the BS of RelyX ARC after 6 months of storage. Clinical significance: The use of chlorhexidine solution seems not to improve the bond strength of fibre posts to root canals, disregarding the composition of the luting cement. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:735 / 741
页数:7
相关论文
共 50 条
  • [41] Influence of thermocycling on glass-ionomer cement reinforced with short glass-fibers.
    Kawano, F
    Kon, M
    Kobayashi, M
    Asaoka, K
    Ichikawa, T
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 539 - 539
  • [42] In vitro and in vivo investigation of the biological and mechanical behaviour of resin-modified glass-ionomer cement containing chlorhexidine
    Freire de Castilho, Aline Rogeria
    Duque, Cristiane
    Negrini, Thais de Cassia
    Sacono, Nancy Tomoko
    de Paula, Andreia Bolzan
    de Souza Costa, Carlos Alberto
    Palomari Spolidorio, Denise Madalena
    Puppin-Rontani, Regina Maria
    JOURNAL OF DENTISTRY, 2013, 41 (02) : 155 - 163
  • [43] GLASS-IONOMER INSERTION TIME AND BOND-STRENGTH TO DENTIN
    FINOCCHIETTI, PI
    EDELBERG, MH
    BEIGELIS, AA
    JOURNAL OF DENTAL RESEARCH, 1987, 66 (04) : 815 - 815
  • [44] SHEAR BOND STRENGTH OF GLASS-IONOMER BONDED ORTHODONTIC BRACKETS
    JAOCHAKARASIRI, P
    TECHASOMBOORANAKIT, K
    NATHANSON, D
    GIANELLY, A
    GIORDANO, R
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 461 - 461
  • [45] A STUDY OF THE SHEAR BOND STRENGTH OF COMPOSITE RESIN TO LIGHT-CURING GLASS-IONOMER CEMENTS
    KIM, D
    MIN, BS
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 991 - 991
  • [46] Salivary contamination and bond strength of glass-ionomer to dentine.
    Kulczyk, KE
    Sidhu, SK
    McCabe, JF
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 502 - 502
  • [47] Shear bond strength of a glass-ionomer bonding system.
    Van der Vyver, PJ
    De Wet, FA
    Schimper, JH
    Botha, SJ
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1275 - 1275
  • [48] Effects of etching and adhesive applications on the bond strength between composite resin and glass-ionomer cements
    Pamir, Tijen
    Sen, Bilge Hakan
    Evcin, Ozgur
    JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (06) : 636 - 642
  • [49] BOND STRENGTH OF ORTHODONTIC BRACKETS USING A NEW GLASS-IONOMER
    JOSEPH, VP
    HARRIS, AMP
    GROBLER, SR
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 197 - 197
  • [50] Bond strength and interface micromorphology of an improved resin-modified glass ionomer cement
    Pereira, PNR
    Yamada, T
    Tei, R
    Tagami, J
    AMERICAN JOURNAL OF DENTISTRY, 1997, 10 (03): : 128 - 132