Influence of 2% chlorhexidine digluconate on bond strength of a glass-fibre post luted with resin or glass-ionomer based cement

被引:14
|
作者
Gadelha de Araujo, Diana Ferreira [1 ]
Chaves, Larissa Pinceli [1 ]
Bim Junior, Odair [1 ]
Pimentel Garcia, Fernanda Cristina [2 ]
Ishikiriama, Sergio Kiyoshi [1 ]
Honorio, Heitor Marques [3 ]
Wang, Linda [1 ]
机构
[1] Univ Sao Paulo, Dept Operat Dent Endodont & Dent Mat, Bauru Sch Dent, Bauru, SP, Brazil
[2] Univ Brasilia UnB, Dent Mat Area, Dept Restorat Dent, Brasilia, DF, Brazil
[3] Univ Sao Paulo, Bauru Sch Dent, Dept Pediat Dent Orthodont & Collect Hlth, Bauru, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Bond strength; Chlorhexidine; Dual-cure resin cement; Resin-modified glass-ionomer cement; Root canal; ROOT DENTIN; HYGROSCOPIC EXPANSION; TEETH; ADHESION; RESISTANCE;
D O I
10.1016/j.jdent.2014.02.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the influence of 2% chlorhexidine digluconate (CHX) on the bond strength (BS) of a glass-fibre post to the root canal, regarding the cements (dual-cured resin or resin-modified glass-ionomer cement), the root thirds and the time of storage. Method: Eighty bovine roots were selected and endodontically treated, before being randomly assigned to the following groups according to the luting protocol: ARC (RelyX ARC); ARC + CHX; RL (RelyX Luting 2); and RL + CHX. After 24 h of luting, the roots were sliced to obtain 1 mm-thick slices. Half of each group was submitted to either 7-day or 6-month storage in artificial saliva (n = 10). The specimens were subjected to push-out tests with a crosshead speed of 0.5 mm/min. The data were analysed with four-way ANOVA and Tukey's test (P <= 0.05). The failure modes were analysed with a digital microscope (50 x and 200x). Results: ARC yielded a significantly higher BS compared to RL (P < 0.001). Despite CHX exerted a significant effect; it depends on the interaction with the luting cement and time (P < 0.001). Thus, CHX decreased the values of BS to those of ARC after 6 months (P < 0.001). On the 7th day of storage, the ARC + CHX presented higher BS to the cervical and middle thirds compared to RL + CHX (P = 0.012). Time solely was not a significant factor (P = 0.081). Adhesive cement-dentine type and mixed failures were predominant modes for the ARC groups. For the RL groups, the main failures were adhesive cement-post and mixed modes. Conclusions: Glass-fibre posts luted with RelyX ARC dual-cure resin cement exhibited higher BS than those luted with RelyX Luting 2 resin-modified glass-ionomer cement. Furthermore, CHX was not effective to improve the BS and negatively affected the BS of RelyX ARC after 6 months of storage. Clinical significance: The use of chlorhexidine solution seems not to improve the bond strength of fibre posts to root canals, disregarding the composition of the luting cement. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:735 / 741
页数:7
相关论文
共 50 条
  • [31] SHEAR BOND STRENGTH AND MARGINAL MICROLEAKAGE OF GLASS-IONOMER CEMENT AFTER DENTIN TREATMENT
    PRATI, C
    NUCCI, C
    MONTANARI, G
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 627 - 627
  • [32] Enhancement effect of pre-reacted glass on strength of glass-ionomer cement
    Monmaturapoj, Naruporn
    Soodsawang, Wiwaporn
    Tanodekaew, Siriporn
    DENTAL MATERIALS JOURNAL, 2012, 31 (01) : 125 - 130
  • [33] Self-etching adhesives improve the shear bond strength of a resin-modified glass-ionomer cement to dentin
    Besnault, C
    Attal, JP
    Ruse, D
    Degrange, M
    JOURNAL OF ADHESIVE DENTISTRY, 2004, 6 (01): : 55 - 59
  • [34] Influence of ultrasonic setting on tensile bond strength of glass-ionomer cements to dentin
    Fagundes, Ticiane Cestari
    Esteves Barata, Terezinha Jesus
    Bresciani, Eduardo
    Gigo Cefaly, Daniela Francisca
    Ramos Carvalho, Carlos Augusto
    Lima Navarro, Maria Fidela
    JOURNAL OF ADHESIVE DENTISTRY, 2006, 8 (06): : 401 - 407
  • [35] Reinforcement of resin-modified glass-ionomer cement with glass fiber and graphene oxide
    Sari, Fatmanur
    Ugurlu, Muhittin
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 142
  • [36] Influence of silane and solvated bonding agents on the bond strength to glass-fibre posts
    Oliveira, Aline S.
    Ramalho, Elisa S.
    Spazzin, Aloisio O.
    Naves, Lucas Z.
    Moraes, Rafael R.
    AUSTRALIAN ENDODONTIC JOURNAL, 2013, 39 (03) : 122 - 125
  • [37] Regional Bond Strength to Lateral Walls in Class I and II Ceramic Inlays Luted with Four Resin Cements and Glass-Ionomer Luting Agent
    Manso, Ana G. M.
    Gonzalez-Lopez, Santiago
    Bolanos-Carmona, Victoria
    Mauricio, Paulo J. B. T. D.
    Felix, Sergio A.
    Carvalho, Patricia A.
    JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (05): : 455 - 465
  • [39] Comparative evaluation of tensile bond strength and microleakage of conventional glass ionomer cement, resin modified glass ionomer cement and compomer: An in vitro study
    Rekha, C. Vishnu
    Varma, Balagopal
    Jayanthi
    CONTEMPORARY CLINICAL DENTISTRY, 2012, 3 (03) : 282 - 287
  • [40] EFFECT OF HYDRATION ON THE BIAXIAL FLEXURAL STRENGTH OF A GLASS-IONOMER CEMENT
    SHEN, CY
    GRIMAUDO, N
    DENTAL MATERIALS, 1994, 10 (03) : 190 - 195