Accuracy of Transcutaneous Carbon Dioxide Levels in Comparison to Arterial Carbon Dioxide Levels in Critically Ill Children

被引:8
|
作者
Bhalla, Anoopindar K. [1 ,2 ]
Khemani, Robinder G. [1 ,2 ]
Hotz, Justin C. [1 ]
Morzov, Rica P. [1 ]
Newth, Christopher J. L. [1 ,2 ]
机构
[1] Childrens Hosp Los Angeles, Dept Anesthesiol & Crit Care Med, Los Angeles, CA 90027 USA
[2] Univ Southern Calif, Keck Sch Med, Los Angeles, CA USA
关键词
capnography; carbon dioxide; pediatric intensive care unit; monitoring; physiologic; respiration; artificial; heart disease; ACUTE LUNG INJURY; DEAD SPACE; INFANTS; VENTILATION; MORTALITY; OXIMETRY;
D O I
10.4187/respcare.06209
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Widespread use of transcutaneous P-CO2 (P-tcCO2) monitoring is currently limited by concerns many practitioners have regarding accuracy. We compared the accuracy of P(tcCO2 )with that of P-aCO2 measurements in critically ill children, and we investigated whether clinical conditions associated with low cardiac output or increased subcutaneous tissue affect this accuracy. METHODS: We performed a single-center prospective study of critically ill children placed on transcutaneous monitoring. RESULTS: There were 184 children enrolled with paired P-aCO2 and P-tcCO2, values. Subjects had a median age of 31.8 mo (interquartile range 3.5-123.3 mo). Most children were mechanically ventilated (n = 161, 87.5%), and many had cardiac disease (n = 76, 41.3%). The median P-aCO2, was 44 mm Hg (interquartile range 39-51 mm Hg). The mean bias between , and P-aCO2 was 0.6 mm Hg with 95% limits of agreement from -13.6 to 14.7 mm Hg. The P-tcCO2 and P-aCO2 were within +/- 5 mm Hg in 126 (68.5%) measurements. In multivariable modeling, cyanotic heart disease (odds ratio 3.5, 95% CI 1.2-10, P = .02) and monitor number 2 (odds ratio 3.8 95% CI 1.3-10.5, P = .01) remained associated with P-tcCO2, >= 5 mm Hg higher than P-aCO2. Serum lactate, fluid balance, renal failure, obesity, vasoactive-inotrope score, and acyanotic heart disease were not associated with high or low P(tcCO2 )values. In 130 children with a second paired P-tcCO2, and P-aCO2 measurement, predicting the second measured P-aCO2 by subtracting the initial observed difference between the P-tcCO2, and P-aCO2. from the subsequent measured P-tcCO2 decreased the mean bias between observed and predicted P-aCO2 to 0.2 mm Hg and the 95% limits of agreement to -9.4 to 9.7 mm Hg. CONCLUSIONS: P-tcCO2, provides an acceptable estimate of P(aCO2 )in many critically ill children, including those with clinical conditions that may be associated with low cardiac output or increased subcutaneous tissue, although it does not perform as well in children with cyanotic heart disease. P(tcCO2 )may be a useful adjunct monitoring method, but it cannot reliably replace P-aCO2, measurement.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 50 条
  • [31] Relationship between end-tidal carbon dioxide and arterial carbon dioxide in critically ill patients on mechanical ventilation A cross-sectional study
    Wang, Jinrong
    Zhang, Jianjun
    Liu, Yajing
    Shang, Huimian
    Peng, Li
    Cui, Zhaobo
    MEDICINE, 2021, 100 (33)
  • [32] Carbon dioxide and the critically ill - too little of a good thing?
    Laffey, JG
    Kavanagh, BP
    LANCET, 1999, 354 (9186): : 1283 - 1286
  • [33] Carbon dioxide levels of ventilated adult critically ill post-operative patients on arrival at the intensive care unit
    Slave, M.
    Scribante, J.
    Perrie, H.
    Lambat, F.
    SOUTHERN AFRICAN JOURNAL OF CRITICAL CARE, 2023, 39 (01) : 13 - 18
  • [34] Obesity hypoventilation syndrome in Japan and independent determinants of arterial carbon dioxide levels
    Harada, Yuka
    Chihara, Yuichi
    Azuma, Masanori
    Murase, Kimihiko
    Toyama, Yoshiro
    Yoshimura, Chikara
    Oga, Toru
    Nakamura, Hiroshi
    Mishima, Michiaki
    Chin, Kazuo
    RESPIROLOGY, 2014, 19 (08) : 1233 - 1240
  • [35] OBESITY HYPOVENTILATION SYNDROME IN JAPAN AND INDEPENDENT DETERMINANTS OF ARTERIAL CARBON DIOXIDE LEVELS
    Harada, Yuka
    Chihara, Yuichi
    Hamada, Satoshi
    Azuma, Masanori
    Murase, Kimihiko
    Toyama, Yoshiro
    Tanizawa, Kiminobu
    Yoshimura, Chikara
    Hitomi, Takefumi
    Handa, Tomohiro
    Oga, Toru
    Tsuboi, Tomomasa
    Mishima, Michiaki
    Chin, Kazuo
    RESPIROLOGY, 2013, 18 : 189 - 189
  • [36] Are Transcutaneous Oxygen and Carbon Dioxide Determinations of Value in Pulmonary Arterial Hypertension?
    Tonelli, Adriano R.
    Alkukhun, Laith
    Cikach, Frank
    Ahmed, Mostafa
    Dweik, Raed A.
    MICROCIRCULATION, 2015, 22 (04) : 249 - 256
  • [37] Unmanned assessment of respirator carbon dioxide levels: Comparison of methods of measurement
    Caretti, David
    Coyne, Karen M.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2008, 5 (05) : 305 - 312
  • [38] Ambulatory transcutaneous carbon dioxide monitoring for children with neuromuscular disease
    Shi, Jenny
    Chiang, Jackie
    Ambreen, Munazzah
    Snow, Nadia
    Mocanu, Cora
    McAdam, Laura
    Goldstein, Roger S.
    Rose, Louise
    Amin, Reshma
    SLEEP MEDICINE, 2023, 101 : 221 - 227
  • [39] ANALYZING ATMOSPHERIC CARBON-DIOXIDE LEVELS
    RYCROFT, MJ
    NATURE, 1982, 295 (5846) : 190 - 191
  • [40] The impact of low levels of carbon dioxide on rats
    Krohn, TC
    Hansen, AK
    Dragsted, N
    LABORATORY ANIMALS, 2003, 37 (02) : 94 - 99