Accuracy of Transcutaneous Carbon Dioxide Levels in Comparison to Arterial Carbon Dioxide Levels in Critically Ill Children

被引:8
|
作者
Bhalla, Anoopindar K. [1 ,2 ]
Khemani, Robinder G. [1 ,2 ]
Hotz, Justin C. [1 ]
Morzov, Rica P. [1 ]
Newth, Christopher J. L. [1 ,2 ]
机构
[1] Childrens Hosp Los Angeles, Dept Anesthesiol & Crit Care Med, Los Angeles, CA 90027 USA
[2] Univ Southern Calif, Keck Sch Med, Los Angeles, CA USA
关键词
capnography; carbon dioxide; pediatric intensive care unit; monitoring; physiologic; respiration; artificial; heart disease; ACUTE LUNG INJURY; DEAD SPACE; INFANTS; VENTILATION; MORTALITY; OXIMETRY;
D O I
10.4187/respcare.06209
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Widespread use of transcutaneous P-CO2 (P-tcCO2) monitoring is currently limited by concerns many practitioners have regarding accuracy. We compared the accuracy of P(tcCO2 )with that of P-aCO2 measurements in critically ill children, and we investigated whether clinical conditions associated with low cardiac output or increased subcutaneous tissue affect this accuracy. METHODS: We performed a single-center prospective study of critically ill children placed on transcutaneous monitoring. RESULTS: There were 184 children enrolled with paired P-aCO2 and P-tcCO2, values. Subjects had a median age of 31.8 mo (interquartile range 3.5-123.3 mo). Most children were mechanically ventilated (n = 161, 87.5%), and many had cardiac disease (n = 76, 41.3%). The median P-aCO2, was 44 mm Hg (interquartile range 39-51 mm Hg). The mean bias between , and P-aCO2 was 0.6 mm Hg with 95% limits of agreement from -13.6 to 14.7 mm Hg. The P-tcCO2 and P-aCO2 were within +/- 5 mm Hg in 126 (68.5%) measurements. In multivariable modeling, cyanotic heart disease (odds ratio 3.5, 95% CI 1.2-10, P = .02) and monitor number 2 (odds ratio 3.8 95% CI 1.3-10.5, P = .01) remained associated with P-tcCO2, >= 5 mm Hg higher than P-aCO2. Serum lactate, fluid balance, renal failure, obesity, vasoactive-inotrope score, and acyanotic heart disease were not associated with high or low P(tcCO2 )values. In 130 children with a second paired P-tcCO2, and P-aCO2 measurement, predicting the second measured P-aCO2 by subtracting the initial observed difference between the P-tcCO2, and P-aCO2. from the subsequent measured P-tcCO2 decreased the mean bias between observed and predicted P-aCO2 to 0.2 mm Hg and the 95% limits of agreement to -9.4 to 9.7 mm Hg. CONCLUSIONS: P-tcCO2, provides an acceptable estimate of P(aCO2 )in many critically ill children, including those with clinical conditions that may be associated with low cardiac output or increased subcutaneous tissue, although it does not perform as well in children with cyanotic heart disease. P(tcCO2 )may be a useful adjunct monitoring method, but it cannot reliably replace P-aCO2, measurement.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 50 条
  • [21] Disparity Between Mainstream and Sidestream End-Tidal Carbon Dioxide Values and Arterial Carbon Dioxide Levels
    Pekdemir, Murat
    Cinar, Orhan
    Yilmaz, Serkan
    Yaka, Elif
    Yuksel, Melih
    RESPIRATORY CARE, 2013, 58 (07) : 1152 - 1156
  • [22] Utility of end-tidal carbon dioxide monitoring in critically ill children
    Totapally, Balagangadhar R.
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2014, 18 (06) : 341 - 342
  • [23] CARBON DIOXIDE AND OXYGEN BLOOD LEVELS WITH A CARBON DIOXIDE CONTROLLED ARTIFICIAL RESPIRATOR
    FRUMIN, MJ
    BERGMAN, NA
    HOLADAY, DA
    ANESTHESIOLOGY, 1959, 20 (03) : 313 - 320
  • [24] Transcutaneous carbon dioxide monitoring
    McCormack, J. G.
    ANAESTHESIA, 2007, 62 (08) : 850 - 851
  • [25] Concordance between transcutaneous and arterial measurements of carbon dioxide in an ED
    Delerme, Samuel
    Montout, Viviane
    Goulet, Helene
    Arhan, Amandine
    Le Sache, Frederic
    Devilliers, Catherine
    Riou, Bruno
    Ray, Patrick
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (09): : 1872 - 1876
  • [26] ACCURACY OF TRANSCUTANEOUS CARBON DIOXIDE MEASUREMENT FOR CHANGE OVER TIME
    Fingleton, James
    Mckinstry, Steve
    Pilcher, Janine
    Weatherall, Mark
    Beasley, Richard
    Bardsley, George
    RESPIROLOGY, 2017, 22 : 98 - 98
  • [27] Accuracy of transcutaneous carbon dioxide monitoring during sleep studies
    Thomas, C.
    Keeley, M.
    Julie, T.
    Warren, R.
    Christine, McD
    Christopher, W.
    RESPIROLOGY, 2023, 28 : 14 - 14
  • [28] Agreement of carbon dioxide levels measured by arterial, transcutaneous and end tidal methods in preterm infants ≤ 28 weeks gestation
    Aliwalas L.L.D.
    Noble L.
    Nesbitt K.
    Fallah S.
    Shah V.
    Shah P.S.
    Journal of Perinatology, 2005, 25 (1) : 26 - 29
  • [29] Correlation of carbon dioxide levels as measured by arterial, transcutaneous and end tidal methods in preterm infants ≤ 28 weeks gestation
    Aliwalas, LLD
    Noble, L
    Nesbitt, K
    Fallah, S
    Shah, V
    Shah, PS
    PEDIATRIC RESEARCH, 2004, 55 (04) : 534A - 534A
  • [30] Validity of sidestream endtidal carbon dioxide measurement in critically ill, mechanically ventilated children
    van der Heijden, Hylke H. A. C. M.
    Truin, Gerben J.
    Verhaeg, Joyce
    van der Pol, Peggy
    Lemson, Joris
    PEDIATRIC ANESTHESIA, 2016, 26 (03) : 294 - 299