In vitro evaluation of the marginal fit of different all-ceramic crowns

被引:9
|
作者
Yucel, Munir Tolga [1 ]
Aykent, Filiz [1 ]
Avunduk, Mustafa Cihat [2 ]
机构
[1] Selcuk Univ, Fac Dent, Dept Prosthodont, TR-42079 Konya, Turkey
[2] Univ Necmettin Erbakan, Fac Med, Dept Pathol, Konya, Turkey
关键词
all-ceramics; CAD/CAM; Celay; image analysis; marginal fit; CLINICAL-EVALUATION; FRACTURE STRENGTH; SYSTEMS; RESTORATIONS; CEMENTATION; DISCREPANCIES; ADAPTATION; PRECISION; THICKNESS;
D O I
10.1016/j.jds.2012.05.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: The marginal fit of all-ceramic restorations is a very important criterion for their long-term success. The aim of this in vitro study was to compare the marginal adaptation of crowns fabricated with four different all-ceramic systems using an image analysis method. Materials and methods: A standardized all-ceramic preparation was made on a stainless steel die. Eighty gypsum dies were duplicated from this die and randomly divided into four groups of 20 each. Cerec 3, In-Ceram, IPS Empress 2, and Celay crowns were fabricated on dies of each group following the manufacturers' instructions. Marginal gaps of the crowns were evaluated without cementation on their own gypsum dies and then on the master die with a stereomicro-scope and image analysis program. Two-way analysis of variance and Tukey's honest significant difference tests were used to evaluate the data (alpha = 0.01). Results: Mean gap dimensions and standard deviations at the marginal opening of the crowns evaluated on the gypsum dies were 21.5 +/- 4 mu m for Celay, 29.3 +/- 5 mu m for IPS Empress 2, 33 +/- 4 mu m for Cerec 3, and 74.6 +/- 10 mu m for In-Ceram crowns. Mean gap dimensions and standard deviations at the marginal opening of crowns evaluated on the master steel die were 27.8 +/- 4 mu m for Celay, 41.5 +/- 7 mu M for IPS Empress 2, 47.4 +/- 5 mu m for Cerec 3, and 94.9 +/- 10 mu m for In-Ceram crowns. Marginal opening values measured on the master die were higher than those of gypsum dies. Conclusion: In-Ceram all-ceramic crowns showed the largest marginal gap, and Celay crowns showed the smallest marginal gap in both die groups. The marginal discrepancies found in this study were all within the clinically acceptable standard of 120 mu m. Copyright (C) 2012, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:225 / 230
页数:6
相关论文
共 50 条
  • [31] The effect of different finish line and convergence angle on the marginal fit of zirconia all-ceramic restorations
    Ahmadzadeh, Assadolah
    Lavaf, Shirin
    Sarbazi, Amir Hossein
    Rohani, Ali
    Sepehri, Sajad
    [J]. MEDICAL SCIENCE, 2019, 23 (99) : 678 - 684
  • [32] Simulation of clinical fractures for three different all-ceramic crowns
    Oilo, Marit
    Kvam, Ketil
    Gjerdet, Nils R.
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2014, 122 (03) : 245 - 250
  • [33] Evaluation of effect of different resin luting cements on fracture load of all-ceramic crowns
    Yenisey, M.
    Kulunk, T.
    Ceylan, G.
    Guler, A. U.
    Secilmis, A.
    [J]. MATERIALS RESEARCH INNOVATIONS, 2009, 13 (04) : 481 - 485
  • [34] Marginal Fit of Implant-Supported All-Ceramic Zirconia Frameworks
    Zaghloul, Hanaa Hassan
    Younis, Jihan Farouk
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (04) : 417 - 424
  • [35] Marginal and laternal fit of two all-ceramic crown systems.
    Attia, A
    Kara, M
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B246 - B246
  • [36] Probability of fracture of all-ceramic crowns
    Chai, J
    Takahashi, Y
    Sulaiman, F
    Chong, KH
    Lautenschlager, EP
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (05) : 420 - 424
  • [37] Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation
    Wolfart, S
    Wegner, SM
    Al-Halabi, A
    Kern, M
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (06) : 587 - 592
  • [38] Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions
    Zarauz, Cristina
    Valverde, Arelhys
    Martinez-Rus, Francisco
    Hassan, Bassam
    Pradies, Guillermo
    [J]. CLINICAL ORAL INVESTIGATIONS, 2016, 20 (04) : 799 - 806
  • [39] Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions
    Cristina Zarauz
    Arelhys Valverde
    Francisco Martinez-Rus
    Bassam Hassan
    Guillermo Pradies
    [J]. Clinical Oral Investigations, 2016, 20 : 799 - 806
  • [40] Fracture strength of all-ceramic crowns
    Sobrinho, LC
    Cattell, MJ
    Knowles, JC
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (10) : 555 - 559