摘要
Background and Objectives: The precise degree of marginal fit is one of the most significant criteria for the durable success of all-ceramic restorations. Since the finishing line designs and preparation angles can affect the marginal fit, the aim of the present study was to compare the effect of different finish line and convergence angle on the marginal fit of zirconia all-ceramic restorations. Materials and methods: In the present in vitro study a total of four brass dies were designed with Auto CAD software and manufactured with CNC machine (Siemens, SI Numerik 802D-SL; USA) as follow: Die A: Convergence angle of 12 degrees and radial shoulder margin, Die B: Convergence angle of 6 degrees and sloping shoulder of 135 degrees, Die C: Convergence angle of 6 degrees and radial shoulder margin, Die D: Convergence angle of 12 degrees and sloping shoulder of 135 degrees. A total of 40 plaster dies were divided in four groups of 10 (n=10), ten impressions were carried out by the double impression technique with a poly vinyl siloxane impression material for each master die. The impression was poured with type IV Plaster. A ceramic restoration was made for each plaster die then the marginal gaps were measured with SEM. Data were analysed using the two-way analysis of variance (ANOVA) and SPSS ver. 16. Results: The lowest mean (+/- standard deviation) marginal gap was observed in group A (31.9423), group D (36.03), group B (40.9537), group C (46.703), respectively. Different convergance angle had significant effect on marginal fittness (P <0.05), but marginal design had no significant effect on marginal fitness (p>0.05) and both of them together could affect on marginal fitness (p<0/05). Conclusion: The type of the finish line did not influence the marginal fit. The convergence angle influences the distance from the edge of the crown to the edge of the tooth finish line. It seems that use the convergance angle of 12 degree and radial shoulder margin can reduce the marginal gap in zirconia all-ceramic restorations.
引用
收藏
页码:678 / 684
页数:7
相关论文
共 50 条
  • [1] The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns
    Tao, Jianxiang
    Han, Dongwei
    [J]. QUINTESSENCE INTERNATIONAL, 2009, 40 (09): : 745 - 752
  • [2] Marginal Fit of Implant-Supported All-Ceramic Zirconia Frameworks
    Zaghloul, Hanaa Hassan
    Younis, Jihan Farouk
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (04) : 417 - 424
  • [3] In vitro evaluation of the marginal fit of different all-ceramic crowns
    Yucel, Munir Tolga
    Aykent, Filiz
    Avunduk, Mustafa Cihat
    [J]. JOURNAL OF DENTAL SCIENCES, 2013, 8 (03) : 225 - 230
  • [4] Is Zirconia the Holy Grail of All-Ceramic Restorations?
    Zhang, Yu
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (04) : 378 - 379
  • [5] Marginal Integrity of Turkom-Cera Compared to Other All-Ceramic Materials: Effect of Finish Line
    AL-Makramani, Bandar M. A.
    Razak, Abdul A. A.
    Abu-Hassan, Mohamed I.
    Sulaiman, Eshamsul
    Loon, Lui Joo
    Yahya, Noor Azlin
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (04) : 379 - 381
  • [6] In Vitro Effect of Thickness of Veneering Ceramic on Color Parameters of Zirconia All-Ceramic Restorations
    Jalalian, Ezzat Allah
    Zarbakhsh, Arash
    Attar, Kimia
    Ghane, Hadi Kaseb
    Shirian, Amir Ali
    Manoochehri, Negar
    [J]. JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2018, 6 (02): : 586 - 592
  • [7] The influence of colored zirconia on the optical properties of all-ceramic restorations
    Harada, Rino
    Takemoto, Shinji
    Hattori, Masayuki
    Yoshinari, Masao
    Oda, Yutaka
    Kawada, Eiji
    [J]. DENTAL MATERIALS JOURNAL, 2015, 34 (06) : 918 - 924
  • [8] A method of verifying and improving internal fit of all-ceramic restorations
    Jahangiri, L
    Estafan, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (01): : 82 - 83
  • [9] Effect of Luting Cement and Convergence Angle of the Preparation on the Internal Fit of Zirconia Restorations
    Sanchez-Monescillo, Andres
    Gonzalez-Serrano, Carlos
    Gonzalez-Serrano, Jose
    Malta Barbosa, Joao
    Lopez-Suarez, Carlos
    Duarte, Sillas, Jr.
    [J]. MATERIALS, 2021, 14 (24)
  • [10] Clinical marginal and internal gaps of zirconia all-ceramic crowns
    Kokubo, Yuji
    Tsumita, Mitsuyoshi
    Kano, Takamitsu
    Sakurai, Satoe
    Fukushima, Shunji
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2011, 55 (01) : 40 - 43