Experimental analysis of dehumidification performance of an evaporative cooling-assisted internally cooled liquid desiccant dehumidifier

被引:38
|
作者
Park, Joon-Young [1 ]
Kim, Beom-Jun [1 ]
Yoon, Soo-Yeol [1 ]
Byon, Yoo-Suk [1 ]
Jeong, Jae-Weon [1 ]
机构
[1] Hanyang Univ, Coll Engn, Dept Architectural Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Dehumidification system; Internally cooled liquid desiccant system; Desiccant cooling; Evaporative cooling; MASS-TRANSFER PROCESSES; HEAT; MODEL;
D O I
10.1016/j.apenergy.2018.10.101
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The aim of this study is to empirically investigate the impact of the working-to-primary air flow ratio variation on the dehumidification performance of an evaporative cooling-assisted internally cooled liquid desiccant dehumidifier. In the experiment, the process air passed through the primary (or dehumidification) channels of the internally cooled liquid desiccant dehumidifier at a constant flow rate, while the working air flow passing through the secondary (or evaporative cooling) channels was modulated to vary the working-to-primary air flow ratio from 0.25 to 1.0 in 0.25 increments. To evaluate the impact of the working-to-primary air flow ratio on the dehumidification and cooling performance of the internally cooled liquid desiccant dehumidifier, four different performance indices, i.e., cooling capacity, wet-bulb effectiveness, volumetric mass transfer coefficient, and coefficient of performance, were measured in a series of experiments performed under various working-to primary air flow ratios. From those performance indicators, the overall heat, mass transfer performance, and energy efficiency of the internally cooled liquid desiccant dehumidifier could be rated. The experimental results indicate that the maximum values of the four selected performance indices are obtained at a working-to-primary air flow ratio of 0.5. To verify the reliability of the experimental results, a detailed simulation of the internally cooled liquid desiccant dehumidifier was performed using a sorption system simulation program (SorpSim). The measured performance data was in good agreement with the simulation results, within 20% error bounds. Consequently, we determined that the optimal dehumidification and cooling performance of the internally cooled liquid desiccant dehumidifier could be expected when the working-to-primary air flow ratio is 0.5.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 50 条
  • [41] Experimental investigations on a solar assisted liquid desiccant cooling system with indirect contact dehumidifier
    Das, Rajat Subhra
    Jain, Sanjeev
    SOLAR ENERGY, 2017, 153 : 289 - 300
  • [42] Mathematical modeling and parametric study of liquid desiccant system with internally-cooled dehumidifier
    Hendijani, Arash Doustani
    Gilani, Neda
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 5 : 213 - 229
  • [43] Experimental Investigation on Dehumidification Using a Solid Composite Bio Desiccant Internally Cooled Using Nanofluids for Building Cooling
    Kumar, Shiva
    Hariharan, Girish
    Fayaz, Muhammad
    Kumar, Nitesh
    BUILDINGS, 2023, 13 (06)
  • [44] Performance characteristics of a novel internally-cooled plate membrane liquid desiccant air dehumidification system
    Xiao, Liehui
    Yang, Minlin
    Yuan, Wu-Zhi
    Huang, Si-Min
    APPLIED THERMAL ENGINEERING, 2020, 172
  • [45] Performance correlations of an adjacently internally-cooled membrane contactor applied for liquid desiccant air dehumidification
    Huang, Si-Min
    Yang, Minlin
    Hong, Yuxiang
    Ye, Wei-Biao
    APPLIED THERMAL ENGINEERING, 2018, 129 : 1660 - 1669
  • [46] A view on the performance comparison between adiabatic and internally-cooled dehumidification processes using liquid desiccant
    Luo, Jielin
    Wang, Qiliang
    Zhang, Yanling
    Yang, Hongxing
    DESALINATION, 2024, 586
  • [47] Transient performance study of an internally-cooled plate membrane liquid desiccant air dehumidification system
    Yang, Yu
    Yan, Junwei
    Zhou, Xuan
    Xiao, Liehui
    Huang, Si-Min
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 (131) : 87 - 100
  • [48] Operating Energy Savings of a Liquid Desiccant and Evaporative Cooling-Assisted Air-Handling System in Marine Applications
    Park, Joon-Young
    Jeong, Jae-Weon
    ENERGIES, 2017, 10 (04)
  • [49] Retrofit of a liquid desiccant and evaporative cooling-assisted 100% outdoor air system for enhancing energy saving potential
    Kim, Min-Hwi
    Yoon, Dong-Seop
    Kim, Hui-Jeong
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2016, 96 : 441 - 453
  • [50] Experimental study and performance analysis on a new dehumidifier with outside evaporative cooling
    Cheng, Xiaosong
    Peng, Donggen
    Yin, Yonggao
    Xu, Shaohua
    Luo, Danting
    BUILDING AND ENVIRONMENT, 2019, 148 : 200 - 211