Calibration of PM-355 nuclear track detectors;: comparison of track diameter diagrams with track depth characteristics

被引:10
|
作者
Szydlowski, A [1 ]
Sartowska, B
Banaszak, A
Choinski, J
Fijal, I
Jaskóla, M
Korman, A
Sadowski, MJ
机构
[1] Andrzej Soltan Inst Nucl Studies IPJ, PL-05400 Otwock, Poland
[2] Inst Nucl Chem & Technol, PL-03195 Warsaw, Poland
[3] Warsaw Univ, Heavy Ion Lab, PL-02097 Warsaw, Poland
关键词
PM-355; nuclear track detectors; track diameters;
D O I
10.1016/j.radmeas.2005.03.021
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The calibration diagrams, i.e. track diameters and track depths versus ion energy and etching time, as obtained for PM-355 track detector irradiated with He-ions are presented. The both detector characteristics are compared. The track etch rate is determined by two methods, as a function of the etch pit depth and the ion energy loss. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:401 / 403
页数:3
相关论文
共 50 条
  • [31] Photoluminescence characterizations and nonlinear optical of PM-355 nuclear track detector film by alpha-particles and laser irradiation
    Alfahed, R. K. Fakher
    Imran, Abdulameer
    Majeed, Munaf S.
    Badran, Hussain Ali
    PHYSICA SCRIPTA, 2020, 95 (07)
  • [32] Structural and optical characterization of alpha-irradiated and chemically etched PM-355 solid state nuclear track detectors before and after solar exposure
    Baig, M. R.
    Alsalhi, M. S.
    Alrasheedi, Mariam G.
    Alfaramawi, K.
    APPLIED RADIATION AND ISOTOPES, 2021, 176
  • [33] Advantage of PM-355 nuclear track detector in light-ion registration and high-temperature plasma diagnostics
    Szydlowski, A
    Banaszak, A
    Czyzewski, T
    Fijal, I
    Jaskóla, M
    Korman, A
    Sadowski, M
    Kretschmer, W
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 325 - 329
  • [34] X-ray irradiation-induced structural modifications in PM-355 polymeric nuclear track detector film
    Nouh, S. A.
    Bahareth, Radiyah A.
    Abutalib, M. M.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (06): : 499 - 505
  • [35] Effect of track etch rate on geometric track characteristics for polymeric track detectors
    Abdel-Naby, AA
    El-Akkad, FA
    RADIATION MEASUREMENTS, 2001, 33 (01) : 145 - 150
  • [36] Characterization of solid state nuclear track detectors of the polyallyl-diglycol-carbonate (CR-39/PM-355) type for light charged particle spectroscopy
    Malinowska, A.
    Jaskola, M.
    Korman, A.
    Szydlowski, A.
    Kuk, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (12):
  • [37] Analysis and correction of track overlapping on nuclear track detectors (SSNTD)
    Palacios, D.
    Sajo-Bohus, L.
    Barros, H.
    Fusella, E.
    Avila, Y.
    REVISTA MEXICANA DE FISICA, 2011, 57 (01) : 34 - 39
  • [38] Influence of intense soft X-ray radiation on the parameters of tracks induced in CR-39 and PM-355 solid state nuclear track detectors
    Szydlowski, A.
    Malinowska, A.
    Szewczak, K.
    Jaskola, M.
    Korman, A.
    Paduch, M.
    Kuk, M.
    RADIATION MEASUREMENTS, 2015, 83 : 26 - 30
  • [39] MECHANISM OF PARTICLE TRACK ETCHING IN POLYMERIC NUCLEAR TRACK DETECTORS
    LUCK, HB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 202 (03): : 497 - 501
  • [40] EFFICIENCY CALIBRATION OF SOLID-STATE NUCLEAR TRACK DETECTORS
    KHAN, HA
    DURRANI, SA
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (02): : 229 - &